Xuejun Gu
Associate Professor of Radiation Oncology (Medical Physics)
Radiation Oncology - Radiation Physics
Bio
Dr. Gu is Associate Professor and Director of Translational Research of Radiation Oncology Department at Stanford University. Dr. Gu's research has been focused on artificial intelligence in medicine, medical imaging and image analysis, and treatment planning. With the research emphasizing on clinical application, she has made unique and significant contributions to translating home-developed software platforms into the clinic and pre-clinic. Dr. Gu is an author on more than 100 peer reviewed publications, a co-inventor on many issued and pending patents, and a co- investigator or principal investigator on NIH and corporate grants. She is on the editorial boards of a number of journals in medical physics and medical imaging.
Academic Appointments
-
Associate Professor - University Medical Line, Radiation Oncology - Radiation Physics
-
Member, Bio-X
-
Member, Stanford Cancer Institute
Administrative Appointments
-
Director of Translational Research, Department of Radiation Oncology, Stanford University (2021 - Present)
Honors & Awards
-
BEST IN PHYSICS (THERAPY), AAPM (2023)
-
BEST IN PHYSICS (THERAPY), AAPM (2019)
-
Science Council, AAPM (2017)
-
BEST IN PHYSICS (JOINT IMAGING THERAPY), AAPM (2016)
-
BEST IN PHYSICS (THERAPY),, AAPM (2015)
-
Norm Baily Postdoctoral/Resident Research Award, AAPM, Southern California Chapter (2011)
-
NCI Ruth L. Kirschstein National Research Service Award, NIH/NCI (2010)
-
Norm Baily Postdoctoral/Resident Research Award, AAPM, Southern California Chapter (2010)
Boards, Advisory Committees, Professional Organizations
-
Associate Editor, Medical Physics (2021 - Present)
-
Associate Editor, British Journal of Radiology (2021 - Present)
-
International Advisory Board, Physics in Medicine & Biology (2021 - Present)
-
Standing Member, NIH-Emerging Imaging Technologies and Applications (EITA) Study Section (2021 - Present)
-
Grant Reviewer, NIH-NIDCR (2019 - 2020)
-
Research Scholar Grant Reviewer, Radiological Society of North America (RSNA) (2015 - 2015)
Professional Education
-
Postdoc, University of California-San Diego, Radiation Physics
-
PhD, Columbia University, Biomedical Engineering
-
MS, Clemson University, Physics
-
BA, Tianjin University, Biomedical Engineering
Current Research and Scholarly Interests
Artificial intelligence in medicine
Medical imaging and image anlysis
Treatment planning and clinical decision-making
FLASH radiobiology study ;
Clinical Trials
-
Neurocognitive Decline in Patients With Brain Metastases
Recruiting
The phase I component of the study is to identify maximal tolerated dose (MTD). The phase II is to evaluate neurocognitive decline.
2024-25 Courses
- Medical Physics and Dosimetry
BMP 251, RADO 251 (Aut) - Physics of Radiation Therapy
BMP 252, RADO 252 (Win) -
Independent Studies (1)
- Graduate Research
BMP 399 (Aut, Win, Spr, Sum)
- Graduate Research
-
Prior Year Courses
2023-24 Courses
- Medical Physics and Dosimetry
BMP 251, RADO 251 (Aut) - Physics of Radiation Therapy
BMP 252, RADO 252 (Win)
- Medical Physics and Dosimetry
Stanford Advisees
-
Postdoctoral Faculty Sponsor
Zhuoran Jiang, Zi Yang, Kangning Zhang -
Postdoctoral Research Mentor
Zhuoran Jiang
All Publications
-
Auto-delineation of treatment target volume for radiation therapy using large language model-aided multimodal learning.
International journal of radiation oncology, biology, physics
2024
Abstract
Artificial intelligence (AI)-aided methods have made significant progress in the auto-delineation of normal tissues. However, these approaches struggle with the auto-contouring of radiotherapy target volume. Our goal is to model the delineation of target volume as a clinical decision-making problem, resolved by leveraging large language model-aided multimodal learning approaches.A vision-language model, termed Medformer, has been developed, employing the hierarchical vision transformer as its backbone, and incorporating large language models to extract text-rich features. The contextually embedded linguistic features are seamlessly integrated into visual features for language-aware visual encoding through the visual language attention module. Metrics, including Dice similarity coefficient (DSC), intersection over union (IOU), and 95th percentile Hausdorff distance (HD95), were used to quantitatively evaluate the performance of our model. The evaluation was conducted on an in-house prostate cancer dataset and a public oropharyngeal carcinoma (OPC) dataset, totaling 668 subjects.Our Medformer achieved a DSC of 0.81 ± 0.10 versus 0.72 ± 0.10, IOU of 0.73 ± 0.12 versus 0.65 ± 0.09, and HD95 of 9.86 ± 9.77 mm versus 19.13 ± 12.96 mm for delineation of gross tumor volume (GTV) on the prostate cancer dataset. Similarly, on the OPC dataset, it achieved a DSC of 0.77 ± 0.11 versus 0.72 ± 0.09, IOU of 0.70 ± 0.09 versus 0.65 ± 0.07, and HD95 of 7.52 ± 4.8 mm versus 13.63 ± 7.13 mm, representing significant improvements (p < 0.05). For delineating the clinical target volume (CTV), Medformer achieved a DSC of 0.91 ± 0.04, IOU of 0.85 ± 0.05, and HD95 of 2.98 ± 1.60 mm, comparable to other state-of-the-art algorithms.Auto-delineation of the treatment target based on multimodal learning outperforms conventional approaches that rely purely on visual features. Our method could be adopted into routine practice to rapidly contour CTV/GTV.
View details for DOI 10.1016/j.ijrobp.2024.07.2149
View details for PubMedID 39117164
-
Motion analysis comparing surface imaging and diaphragm tracking on kV projections for deep inspiration breath hold (DIBH).
Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
2024; 125: 104495
Abstract
Surface-guided imaging (SGI) is increasingly utilized to monitor patient motion during deep inspiration breath hold (DIBH) in radiotherapy. Understanding the association between surface and internal motion is crucial for effective monitoring.To investigate the relation between motion detected by SGI using surface-guided radiotherapy (SGRT) and internal motion measured through diaphragm tracking on kV projections acquired with DIBH for online CBCT.Both SGI and kV were simultaneously acquired for ten patients over a total of 200 breath holds (BH). Diaphragm tracking was performed using second-degree polynomial curve fitting on the derivative images for each kV projection and high-pass filtering at 1/30 Hz to remove rotational effects. The superior-inferior (SI) and anterior-posterior (AP) motions of SGI were then compared to kV tracking using various statistical measures.The correlation (individuals' median: -0.07 to 0.73) was a suboptimal metric for the BH data. The median and 95th percentile absolute differences between SGI-SI and kV were 0.73 mm and 3.46 mm, respectively, during DIBH. For SGI-AP, the corresponding values were 0.55 mm and 2.80 mm. For inter-BH measurements, the contingency table based on a 3 mm threshold indicated surface/diaphragm motion agreement for SGI-SI/kV and SGI-AP/kV was 61 % and 56 %, respectively.Both intra- and inter-BH measurements indicated a limited association between surface and diaphragm motion, with certain constraints noted due to kV tracking and DIBH data. These findings warrant further investigation into the association between surface and internal motion.
View details for DOI 10.1016/j.ejmp.2024.104495
View details for PubMedID 39098107
-
Stereotactic Radiosurgery for Residual, Recurrent, and Metastatic Hemangiopericytomas: A Single-Institution Retrospective Experience.
Neurosurgery
2024
Abstract
BACKGROUND AND OBJECTIVES: Hemangiopericytomas are infrequent vascular tumors originating from Zimmermann pericytes. The conventional treatment involves gross total resection, followed by adjuvant radiotherapy. Nevertheless, their tendency to infiltrate dural sinuses, high vascularity, and anatomic complexity pose challenges for radical resection, leading to a significant risk of recurrence. Stereotactic radiosurgery (SRS) has emerged as a promising adjuvant therapy to address these challenges. Our study provides the largest single-institutional retrospective, aiming to evaluate the effectiveness and safety of SRS as a treatment modality for residual, recurrent, and metastatic hemangiopericytomas.METHODS: From 1998 to 2023, 27 patients with 101 tumors underwent CyberKnife SRS at Stanford University Medical Center. The median age was 51 years at the time of treatment. The median follow-up period from SRS was 103 months (range: 6-250). All patients underwent upfront surgical resection. The median tumor volume was 1.5 cc. The median single-fraction equivalent dose was 19 Gy. The SRS was administered at the 76% of the median isodose line (range: 64-89).RESULTS: Of the 101 treated tumors, 24 (23.8%) progressed with a median time to recurrence of 30 months. At 10 years, the rates of local tumor control (LTC), overall survival (OS), and progression-free survival (PFS) were 74.3%, 80.8%, and 67%, respectively. In patients with metastatic lesions, the LTC rates were significantly greater when compared with those with residual or recurrent tumors. There was no significant difference between patients with residual, recurrent, and metastatic hemangiopericytomas in OS and PFS. Notably, no cases of radiation-induced adverse events were detected.CONCLUSION: SRS leads to excellent LTC, PFS, and OS at 10 years with negligible risk for adverse events. Therefore, it is an effective and safe management modality for patients with residual, recurrent, and metastatic hemangiopericytomas.
View details for DOI 10.1227/neu.0000000000003114
View details for PubMedID 39028180
-
The Role of CyberKnife Stereotactic Radiosurgery in Recurrent Cranial Medulloblastomas across Pediatric and Adult Populations.
Journal of clinical medicine
2024; 13 (12)
Abstract
Background/Objectives: Medulloblastoma is the most common malignant brain tumor in children. In recent decades, the therapeutic landscape has undergone significant changes, with stereotactic radiosurgery (SRS) emerging as a promising treatment for recurrent cases. Our study provides a comprehensive analysis of the long-term efficacy and safety of SRS in recurrent medulloblastomas across both pediatric and adult patients at a single institution. Methods: We retrospectively reviewed the clinical and radiological records of patients who underwent CyberKnife SRS for recurrent cranial medulloblastomas at our institution between 1998 and 2023. Follow-up data were available for 15 medulloblastomas in 10 patients. The cohort comprised eight pediatric patients (ages 3-18) and two adult patients (ages 19-75). The median age at the time of SRS was 13 years, the median tumor volume accounted for 1.9 cc, the median biologically equivalent dose (BED) was 126 Gy, and the single-fraction equivalent dose (SFED) was 18 Gy. The SRS was administered at 75% of the median isodose line. Results: Following a median follow-up of 39 months (range: 6-78), 53.3% of the medulloblastomas progressed, 13.3% regressed, and 33.3% remained stable. The 3-year local tumor control (LTC) rate for all medulloblastomas was 65%, with lower rates observed in the adult cohort (50%) and higher rates in pediatric patients (67%). The 3-year overall survival (OS) rate was 70%, with significantly higher rates in pediatric patients (75%) compared to adult patients (50%). The 3-year progression-free survival (PFS) rate was 58.3%, with higher rates in pediatric patients (60%) compared to adult patients (50%). Two pediatric patients developed radiation-induced edema, while two adult patients experienced radiation necrosis at the latest follow-up, with both adult patients passing away. Conclusions: Our study provides a complex perspective on the efficacy and safety of CyberKnife SRS in treating recurrent cranial medulloblastomas across pediatric and adult populations. The rarity of adverse radiation events (AREs) underscores the safety profile of SRS, reinforcing its role in enhancing treatment outcomes. The intricacies of symptomatic outcomes, intertwined with factors such as age, tumor location, and prior surgeries, emphasize the need for personalized treatment approaches. Our findings underscore the imperative for ongoing research and the development of more refined treatment strategies for recurrent medulloblastomas. Given the observed disparities in treatment outcomes, a more meticulous tailoring of treatment approaches becomes crucial.
View details for DOI 10.3390/jcm13123592
View details for PubMedID 38930121
-
Stereotactic Radiosurgery for Ependymoma in Pediatric and Adult Patients: A Single-Institution Experience.
Neurosurgery
2024
Abstract
Ependymoma is commonly classified as World Health Organization grade 2 with the anaplastic variant categorized as grade 3. Incomplete resection or anaplastic features can result in unfavorable outcomes. Stereotactic radiosurgery (SRS) provides a minimally invasive approach for recurrent ependymomas. Our study investigates the efficacy and safety of SRS for grade 2 and 3 ependymomas in pediatric and adult populations.We conducted a retrospective analysis on 34 patients with 75 ependymomas after CyberKnife SRS between 1998 and 2023. Fourteen were pediatric (3-18 years), and 20 were adult (19-75 years) patients. The median age was 21 years, and the median tumor volume was 0.64 cc. The median single-fraction equivalent dose was 16.6 Gy, with SRS administered at 77% of the median isodose line.After a median follow-up of 42.7 months (range: 3.8-438.3), 22.7% of ependymomas progressed. The 5-year local tumor control rate was 78.1%, varying between 59.6% and 90.2% for children and adults, with grade 2 at 85.9% compared with 58.5% for grade 3 tumors. The 5-year overall survival rate was 73.6%, notably higher in adults (94.7%) than in children (41%), and 100% for grade 2 but decreased to 35.9% for grade 3 patients. The 5-year progression-free survival rate was 68.5%, with 78.3% and 49.2% for adults and children, respectively, and a favorable 88.8% for grade 2, contrasting with 32.6% for grade 3 patients. Symptom improvement was observed in 85.3% of patients. Adverse radiation effects occurred in 21.4% of pediatric patients.Our study supports SRS as a viable modality for pediatric and adult patients with grade 2 and 3 ependymomas. Despite lower local tumor control in pediatric and grade 3 cases, integrating SRS holds promise for improved outcomes. Emphasizing careful patient selection, personalized treatment planning, and long-term follow-up is crucial for optimal neurosurgical outcomes.
View details for DOI 10.1227/neu.0000000000002979
View details for PubMedID 38785440
-
Where Does Auto-Segmentation for Brain Metastases Radiosurgery Stand Today?
Bioengineering (Basel, Switzerland)
2024; 11 (5)
Abstract
Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician's manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.
View details for DOI 10.3390/bioengineering11050454
View details for PubMedID 38790322
-
Exploring deep learning for estimating the isoeffective dose of FLASH irradiation from mouse intestinal histology images.
International journal of radiation oncology, biology, physics
2024
Abstract
Ultra-high dose rate (FLASH) irradiation has been reported to reduce normal tissue damage compared with conventional dose rate (CONV) irradiation without compromising tumor control. This proof-of-concept study aims to develop a deep learning (DL) approach to quantify the FLASH isoeffective dose (dose of CONV that would be required to produce the same effect as the given physical FLASH dose) with post-irradiation mouse intestinal histological images.84 healthy C57BL/6J female mice underwent 16 MeV electron CONV (0.12Gy/s; n=41) or FLASH (200Gy/s; n=43) single fraction whole abdominal irradiation. Physical dose ranged from 12 to 16Gy for FLASH and 11 to 15Gy for CONV in 1Gy increments. 4 days after irradiation, 9 jejunum cross-sections from each mouse were H&E stained and digitized for histological analysis. CONV dataset was randomly split into training (n=33) and testing (n=8) datasets. ResNet101-based DL models were retrained using the CONV training dataset to estimate the dose based on histological features. The classical manual crypt counting (CC) approach was implemented for model comparison. Cross-section-wise mean squared error (CS-MSE) was computed to evaluate the dose estimation accuracy of both approaches. The validated DL model was applied to the FLASH dataset to map the physical FLASH dose into the isoeffective dose.The DL model achieved a CS-MSE of 0.20Gy2 on the CONV testing dataset compared with 0.40Gy2 of the CC approach. Isoeffective doses estimated by the DL model for FLASH doses of 12, 13, 14, 15, and 16 Gy were 12.19±0.46, 12.54±0.37, 12.69±0.26, 12.84±0.26, and 13.03±0.28 Gy, respectively.Our proposed DL model achieved accurate CONV dose estimation. The DL model results indicate that in the physical dose range of 13 to 16 Gy, the biological dose response of small intestinal tissue to FLASH irradiation is represented by a lower isoeffective dose compared to the physical dose. Our DL approach can be a tool for studying isoeffective doses of other radiation dose modifying interventions.
View details for DOI 10.1016/j.ijrobp.2023.12.032
View details for PubMedID 38171387
-
STEREOTACTIC RADIOSURGERY FOR RESIDUAL, RECURRENT, AND METASTATIC HEMANGIOPERICYTOMAS: A SINGLE INSTITUTION EXPERIENCE
OXFORD UNIV PRESS INC. 2023
View details for Web of Science ID 001115245400225
-
Considerations for intensity modulated total body or total marrow and lymphoid irradiation.
Clinical and translational radiation oncology
2023; 43: 100674
Abstract
We compiled a sampling of the treatment techniques of intensity-modulated total body irradiation, total marrow irradiation and total marrow and lymphoid irradiation utilized by several centers across North America and Europe. This manuscript does not serve as a consensus guideline, but rather is meant to serve as a convenient reference for centers that are considering starting an intensity-modulated program.
View details for DOI 10.1016/j.ctro.2023.100674
View details for PubMedID 37753462
-
Stereotactic Radiosurgery for Cranial and Spinal Hemangioblastomas: A Single-Institution Retrospective Series.
Neurosurgery
2023
Abstract
Stereotactic radiosurgery (SRS) has been an attractive treatment modality for both cranial and spinal hemangioblastomas, especially for multiple lesions commonly associated with von Hippel-Lindau (VHL) disease. This study aims to provide the largest long-term analysis of treatment efficacy and adverse effects of SRS for cranial and spinal hemangioblastomas at a single institution.We evaluated the clinical and radiological outcomes of patients with hemangioblastomas treated with CyberKnife SRS at our institute from 1998 to 2022. The follow-up data were available for 135 hemangioblastomas in 35 patients. Twenty-eight patients had 123 hemangioblastomas associated with VHL, and 7 had 12 sporadic hemangioblastomas. The median age was 36 years, and the median tumor volume accounted for 0.4 cc. The SRS was administered with the median single-fraction equivalent dose of 18 Gy to the 77% median isodose line.At a median follow-up of 57 months (range: 3-260), only 20 (16.2%) of the VHL-associated and 1 (8.3%) sporadic hemangioblastomas progressed. The 5-year local tumor control rate was 91.3% for all hemangioblastomas, 91.7% among the sporadic lesions, and 92.9% in patients with VHL. SRS improved tumor-associated symptoms of 98 (74.8%) of 131 symptomatic hemangioblastomas, including headache, neck pain, dizziness, visual disturbances, dysesthesia, ataxia, motor impairment, seizures, and dysphagia. Two patients developed radiation necrosis (5.7%), and 1 of them required surgical resection.SRS is a safe and effective treatment option for patients with hemangioblastomas in critical locations, such as the brainstem, cervicomedullary junction, and spinal cord, and in patients with multiple hemangioblastomas associated with VHL disease.
View details for DOI 10.1227/neu.0000000000002728
View details for PubMedID 37967154
-
Leveraging global binary masks for structure segmentation in medical images.
Physics in medicine and biology
2023
Abstract
Deep learning (DL) models for medical image segmentation are highly influenced by intensity variations of input images and lack generalization due to primarily utilizing pixels' intensity information for inference. Acquiring sufficient training data is another challenge limiting models' applications. Here, we proposed to leverage the consistency of organs' anatomical position and shape information in medical images. We introduced a framework leveraging recurring anatomical patterns through global binary masks for organ segmentation. Two scenarios were studied: (1) Global binary masks were the only input for the U-Net based model, forcing exclusively encoding organs' position and shape information for rough segmentation or localization. (2) Global binary masks were incorporated as an additional channel providing position/shape clues to mitigate training data scarcity. Two datasets of the brain and heart CT images with their ground-truth were split into (26:10:10) and (12:3:5) for training, validation, and test respectively. The two scenarios were evaluated using full training split as well as reduced subsets of training data. In scenario (1), training exclusively on global binary masks led to Dice scores of 0.77±0.06 and 0.85±0.04 for the brain and heart structures respectively. Average Euclidian distance of 3.12±1.43mm and 2.5±0.93mm were obtained relative to the center of mass of the ground truth for the brain and heart structures respectively. The outcomes indicated encoding a surprising degree of position and shape information through global binary masks. In scenario (2), incorporating global binary masks led to significantly higher accuracy relative to the model trained on only CT images in small subsets of training data; the performance improved by 4.3-125.3% and 1.3-48.1% for 1-8 training cases of the brain and heart datasets respectively. The findings imply the advantages of utilizing global binary masks for building models that are robust to image intensity variations as well as an effective approach to boost performance when access to labeled training data is highly limited.
View details for DOI 10.1088/1361-6560/acf2e2
View details for PubMedID 37607564
-
Angular correction methodology and characterization of a high-resolution CMOS array for patient specific quality assurance on a robotic arm linac.
Journal of applied clinical medical physics
2023: e14110
Abstract
PURPOSE: To develop an angular correction methodology and characterize a high-resolution complementary metal-oxide-semiconductor (CMOS) array for patient specific quality assurance on a robotic arm linear accelerator.METHODS: Beam path files from the treatment planning software (TPS) were used to calculate the angle of radiation beam with respect to the detector plane. Beams from multiple discrete angles were delivered to the CMOS detector array and an angular dependency look up table (LUT) was created. The LUT was then used to correct for the angular dependency of the detector. An iso-centric 5mm fixed cone, non iso-centric multi-target fixed cone, 10mm Iris and a multi-leaf collimator (MLC) based collimated plan were delivered to the phantom and compared to the TPS with and without angular correction applied. Additionally, the CMOS array was compared to gafchromic film and a diode array.RESULTS: Large errors of up to 30% were observed for oblique angles. When angular correction was applied, the gamma passing rate increased from 99.2% to 100% (average gamma value decreased from 0.29 to 0.14) for the 5-mm iso-centric cone plan. Similarly, the passing rate increased from 84.0% to 100% for the Iris plan and from 49.98% to 98.4% for the MLC plan when angular correction was applied. For the multi-target plan, applying angular correction improved the gamma passing rate from 94% to 99.6%. The 5mm iso-centric fixed cone plan was also delivered to film, and the gamma passing rate was 91.3% when using gafchromic film as the reference dataset, whereas the diode array provided insufficient sampling for this plan.CONCLUSION: A methodology of calculating the beam angle based on the beam path files was developed and validated. The array was demonstrated to be superior to other quality assurance tools because of its sub-millimeter spatial resolution and immediate read out of the results.
View details for DOI 10.1002/acm2.14110
View details for PubMedID 37528747
-
An Integrated 3D Printed Enclosure for a Radioluminescent-Based Phantom for Quality Assurance on a Robotic-Arm Linac.
Physics in medicine and biology
2023
Abstract
To develop, characterize and improve upon a high-resolution 3D printed radioluminescence-based imaging phantom for quality assurance (QA) of a robotic arm linear accelerator. Approach: A phantom was constructed which consisted of a scintillating sheet, fiducial markers, a low-cost CMOS camera and a 3D printed light-tight enclosure. The camera, equipped with a 12 mm lens, was angled 45 degrees from the horizontal axis with a direct line of sight of the scintillating sheet. A perspective image transformation with optical distortion correction was employed to obtain beam's eye view images for different collimators. Beam profiles, Iris™ field size, MLC leaf positioning and central laser-radiation field coincidence QA tests were performed and compared against data obtained with gafchromic film. The phantom's short-term stability, sensitivity to changes in output, field size and leaf positioning were also assessed. Main Results: The limiting resolution of the optical system was measured to be ~ 0.26 mm. Field size, as measured by the radioluminescence system for Iris apertures, agreed to within 0.2 mm of the values measured using film. The imaging system was sensitive to field size changes well below 0.2 mm and output changes as small as 1 Monitor Unit (MU). For the optical setup, the mean leaf deviation error for banks X1 and X2 was 0.21 and 0.17 mm at 800 mm SAD, whereas the mean difference for the film dataset was 0.16 mm and 0.22 mm for banks X1 and X2, respectively. The optical system was able to detect leaf positioning errors as small as 0.2 mm. Compared with film data, excellent agreement was seen for relative central axis beam profiles for 10 mm and 5 mm beams. Significance: The phantom presented here is an alternative to film and electronic portal imager devices, due to its low-cost, portability, and high spatial and temporal resolution. .
View details for DOI 10.1088/1361-6560/acd162
View details for PubMedID 37116515
-
A deep learning approach for automatic delineation of clinical target volume in stereotactic partial breast irradiation (S-PBI).
Physics in medicine and biology
2023
Abstract
Accurate and efficient delineation of the clinical target volume (CTV) is of utmost significance in post-operative breast cancer radiotherapy. However, CTV delineation is challenging as the exact extent of microscopic disease encompassed by CTV is not visualizable in radiological images and remains uncertain. We proposed to mimic physicians' contouring practice for CTV segmentation in Stereotactic Partial Breast Irradiation (S-PBI) where CTV is derived from tumor bed volume (TBV) via a margin expansion followed by correcting the extensions for anatomical barriers of tumor invasion (e.g., skin, chest wall). We proposed a deep-learning model, where CT images and the corresponding TBV masks formed a multi-channel input for a 3D U-Net based architecture. The design guided the model to encode the location-related image features and directed the network to focus on TBV to initiate CTV segmentation. Gradient weighted Class Activation Map (Grad-CAM) visualizations of the model predictions revealed that the extension rules and geometric/anatomical boundaries were learnt during model training to assist the network to limit the expansion to a certain distance from the chest wall and the skin. We retrospectively collected 175 prone CT images from 35 post-operative breast cancer patients who received 5-fraction partial breast irradiation (PBI) regimen on GammaPod. The 35 patients were randomly split into training (25), validation (5) and test (5) sets. Our model achieved mean (standard deviation) of 0.94 (0.02), 2.46 (0.5) mm, and 0.53 (0.14) mm for Dice similarity coefficient, 95th percentile Hausdorff distance, and average symmetric surface distance respectively on the test set. The results are promising for improving the efficiency and accuracy of CTV delineation process during on-line treatment planning procedure.
View details for DOI 10.1088/1361-6560/accf5e
View details for PubMedID 37084739
-
Stability and reproducibility comparisons between deep inspiration breath-hold techniques for left-sided breast cancer patients: A prospective study.
Journal of applied clinical medical physics
2023: e13906
Abstract
PURPOSE: Deep inspiration breath-hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left-sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT).MATERIALS AND METHODS: We examined intra- and inter-fraction positional variation of the left lung. Eight left-sided breast cancer patients were monitored with electronic portal imaging during breath-hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded.RESULTS: The mean intrafraction stability across all patients for the LLat field was 1.3±0.7% and 1.5±0.9% for VRT and ABC, respectively. Similarly, this was 1.5±0.7% and 1.6±0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0±3.4% and 14.9±6.0% for VRT and ABC, respectively. Similarly, this was 13.0±2.5% and 14.8±9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique.CONCLUSIONS: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline.
View details for DOI 10.1002/acm2.13906
View details for PubMedID 36691339
-
Feasibility and efficacy of active breathing coordinator assisted deep inspiration breath hold technique for treatment of locally advanced breast cancer.
Journal of applied clinical medical physics
2022: e13893
Abstract
Active breathing coordinator (ABC)-assisted deep inspiration breath hold (DIBH) is an important organ sparing radiation therapy (RT) technique for left-sided breast cancer patients. Patients with advanced breast cancer undergoing chest wall and regional nodal irradiation often require a field matching technique. While field matching has been demonstrated to be safe and effective in free breathing patients, its safety and accuracy in DIBH/ABC use has not been previously reported.To report the accuracy, feasibility, and safety of field matching with ABC/DIBH for patients receiving breast/chest wall irradiation with nodal irradiation using a three-field technique.From December 2012 to May 2018, breast cancer patients undergoing ABC/DIBH-based RT at a single institution were reviewed. For each fraction, the amount of overlap/gap between the supraclavicular and the tangential field were measured and recorded. Patient characteristics, including acute and delayed skin toxicities, were analyzed.A total of 202 patients utilized ABC/DIBH and 4973 fractions had gap/overlap measurements available for analysis. The average gap/overlap measured at junction was 0.28 mm ± 0.99 mm. A total of 72% of fractions had no measurable gap/overlap (0 mm), while 5.6% had an overlap and 22.7% a gap. There was no significant trend for worsening or improvement of gap/overlap measurements with increasing fraction number per patient. OSLD measurements were compared to the planned dose. The median dose 1 cm above the junction was 106% ± 7% of planned dose (range 94%-116%). One centimeter below the junction, the median dose was 114% ± 11% of planned dose (range 95%-131%). At the junction, the median dose was 106% ± 16.3% of planned dose (range 86%-131%). Acute skin toxicity was similar to historically reported values (grade 3, 5.4%, grade 4, 0%).ABC-assisted DIBH is a safe and technically feasible method of delivering RT in the setting of complex matching field technique for breast and regional nodal treatments.
View details for DOI 10.1002/acm2.13893
View details for PubMedID 36585853
-
Ensemble learning for glioma patients overall survival prediction using pre-operative MRIs.
Physics in medicine and biology
2022
Abstract
OBJECTIVE: Gliomas are the most common primary brain tumors. And approximately 70% of the glioma patients, whom diagnosed with glioblastoma, have an averaged overall survival (OS) of only ~16 months. Early survival prediction is essential for treatment decision-making in glioma patients. Here we proposed an ensemble learning approach to predict the post-operative OS of glioma patients using only pre-operative MRIs.APPROACH: Our dataset was from the Medical Image Computing and Computer Assisted Intervention (MICCAI) Brain Tumor Segmentation (BraTS) challenge 2020, which consists of multimodal pre-operative MRI scans of 235 glioma patients with survival days recorded. The backbone of our approach was a Siamese network consisting of twinned ResNet-based feature extractors followed by a 3-layer classifier. During training, the feature extractors explored traits of intra and inter-class by minimizing contrastive loss of randomly paired 2D pre-operative MRIs, and the classifier utilized the extracted features to generate labels with cost defined by cross-entropy loss. During testing, the extracted features were also utilized to define distance between the test sample and the reference composed of training data, to generate an additional predictor via K-NN classification. The final label was the ensemble classification from both the Siamese model and the K-NN model.MAIN RESULTS: Our method classify the glioma patients into 3 OS classes: long-survivors (>15 months), mid-survivors (between 10 and 15 months) and short-survivors (< 10 months). The performance is assessed by the accuracy (ACC) and the area under the curve (AUC) of 3-class classification. And the final result achieved an ACC of 65.22% and AUC of 0.81.SIGNIFICANCE: Our Siamese network based ensemble learning approach demonstrated promising ability in mining discriminative features with minimal manual processing and generalization requirement. This prediction strategy can be potentially applied to assist timelier clinical decision-making.
View details for DOI 10.1088/1361-6560/aca375
View details for PubMedID 36384039
-
Global optimization for spot-based treatment planning.
Medical physics
2022
Abstract
PURPOSE: Many radiotherapy modalities can deliver concentrated radiation in the form of spots, such as Gamma Knife (GK), Gamma Pod (GP), intensity modulated proton therapy, and brachytherapy, and can be generalized as spot-based treatments. These treatments have a great therapeutic advantage of creating potent target dose while sparing the surrounding normal tissues. However, global optimization to determine the spot positions, shapes, and intensities is an intractable combinatorial problem for any real 3D problem. The conventional approach adopts heuristic spot selection and intensity optimization in a sequential manner to mitigate the problem complexity. In this work, we propose a novel framework that enables global optimization of spot-based treatment planning.METHOD: The framework is based on kernel decomposition (KD) dose calculation, which models each spot dose as a scaled shift-invariant kernel with the reference kernels and scales pre-calculated. During optimization, the framework incorporates FFT for objective and derivative evaluations and accommodate all spot candidates in optimization search with a temporal complexity of O(N3 logN) as opposed to O(N6 ) complexity in the conventional beamlet framework for volume dimensions of N*N*N. We demonstrated the FFT framework using simulations with different objectives. The framework's planning performance were illustrated using clinical GK and GP cases.RESULTS: Pre-processing involves only a small number of reference kernels and a scale map for the KD model with marginal spatial and temporal overheads. For simulations with 512*512 image dimensions, plan optimization finished in 2 second with FFT while it took 100* longer with the beamlet approach. For clinical cases, the FFT attained solutions within a minute with improved plan quality compared to clinical plans: better conformity and less integral dose because of using a global fine search space for optimal spots.CONCLUSION: The scaled shift-invariance and FFT framework opens a new paradigm for spot-based treatment planning as it can substantially reduce both the spatial and temporal complexities. The framework makes global optimization for spot-based treatment planning clinically feasible. This article is protected by copyright. All rights reserved.
View details for DOI 10.1002/mp.15890
View details for PubMedID 35946601
-
In Reply to Hannoun-Levi et al.
International journal of radiation oncology, biology, physics
2022; 113 (2): 475-477
View details for DOI 10.1016/j.ijrobp.2022.02.034
View details for PubMedID 35569485
-
Registration-guided deep learning image segmentation for cone beam CT-based online adaptive radiotherapy.
Medical physics
2022
Abstract
Adaptive radiotherapy (ART), especially online ART, effectively accounts for positioning errors and anatomical changes. One key component of online ART process is accurately and efficiently delineating organs at risk (OARs) and targets on online images, such as Cone Beam Computed Tomography (CBCT). Direct application of deep learning (DL)-based segmentation to CBCT images suffered from issues such as low image quality and limited available contour labels for training. To overcome these obstacles to online CBCT segmentation, we propose a registration-guided DL (RgDL) segmentation framework that integrates image registration algorithms and DL segmentation models.The RgDL framework is composed of two components: image registration and registration-guided DL segmentation. The image registration algorithm transforms / deforms planning contours, which were subsequently used as guidance by the DL model to obtain accurate final segmentations. We had two implementations of the proposed framework-Rig-RgDL (Rig for rigid body) and Def-RgDL (Def for deformable)-with rigid body (RB) registration or deformable image registration (DIR) as the registration algorithm, respectively, and U-Net as the DL model architecture. The two implementations of RgDL framework were trained and evaluated on seven OARs in an institutional clinical Head and Neck (HN) dataset.Compared to the baseline approaches using the registration or the DL alone, RgDLs achieved more accurate segmentation, as measured by higher mean Dice similarity coefficients (DSC) and other distance-based metrics. Rig-RgDL achieved a DSC of 84.5% on seven OARs on average, higher than RB or DL alone by 4.5% and 4.7%. The average DSC of Def-RgDL was 86.5%, higher than DIR or DL alone by 2.4% and 6.7%. The inference time required by the DL model component to generate final segmentations of seven OARs was less than one second in RgDL. By examining the contours from RgDLs and DL case by case, we found that RgDL was less susceptible to image artifacts. We also studied how the performances of RgDL and DL vary with the size of the training dataset. The DSC of DL dropped by 12.1% as the number of training data decreased from 22 to 5, while RgDL only dropped by 3.4%.By incorporating the patient-specific registration guidance to a population-based DL segmentation model, RgDL framework overcame the obstacles associated with online CBCT segmentation, including low image quality and insufficient training data, and achieved better segmentation accuracy than baseline methods. The resulting segmentation accuracy and efficiency show promise for applying this RgDL framework for online ART. This article is protected by copyright. All rights reserved.
View details for DOI 10.1002/mp.15677
View details for PubMedID 35460584
-
Volumetric dose extension for isodose tuning.
Medical physics
2022
Abstract
PURPOSE: To develop a method that can extend dose from two isodose surfaces (isosurfaces) to the entire patient volume, and to demonstrate its application in radiotherapy plan isodose tuning.METHODS: We hypothesized that volumetric dose distribution can be extended from two isosurfaces-the 100% isosurface and a reference isosurface--with the distances to these two surfaces (Lref ) as extension variables. The extension function is modeled by a three-dimensional lookup table (LUT), where voxel dose values from clinical plans are binned by three indexes: L100 , Lref and Dref (reference dose level). The mean and standard deviation of voxel doses in each bin are calculated and stored in LUT. Volumetric dose extension is performed voxelwisely by indexing the LUT with the L100 , Lref and Dref of each query voxel. The mean dose stored in the corresponding bin is filled into the query voxel as extended dose, and the standard deviation be filled voxelwisely as the uncertainty of extension result. We applied dose extension in isodose tuning, which aims to tune volumetric dose distribution by isosurface dragging. We adopted extended dose as an approximate dose estimation, and combined it with dose correction strategy to achieve accurate dose tuning.RESULTS: We collected 32 post-operative prostate volumetric modulated arc therapy (VMAT) cases and built the LUT and its associated uncertainties from the doses of 27 cases. The dose extension method was tested on five cases, whose dose distributions were defined as ground truth (GT). We extended the doses from 100% and 50% GT isosurfaces to the entire volume, and evaluated the accuracy of extended doses. The 5mm/5% gamma passing rate (GPR) of extended doses are 92.0%. The mean error is 4.5%, which is consistent to the uncertainty estimated by LUT. The dose difference in 90.5% of voxels is within two sigma and 97.5% in three sigma. The calculation time is less than two seconds. To simulate plan isodose tuning, we optimized a dose with less sparing on rectum (than GT dose) and defined it as a "base dose"-the dose awaiting isosurface dragging. In front-end, the simulated isodose tuning is conducted as such that the base dose was given to plan tuner, and its 50% isosurface would be dragged to the desired position (position of 50% isosurface in GT dose). In back-end, the output of isodose tuning is obtained by 1) extending dose from the desired isosurfaces and viewed the extended dose as an approximate dose, 2) obtaining a correction map from the base dose, and 3) applying the correction map to the extended dose. The accuracy of output-extended dose with correction-was 97.2% in GPR (3mm/3%) and less than 1% in mean dose difference. The total calculation time is less than two seconds, which allows for interactive isodose tuning.CONCLUSIONS: We developed a dose extension method that generates volumetric dose distribution from two surfaces. The application of dose extension is in interactive isodose tuning. The distance-based LUT fashion and correction strategy guarantee the computation efficiency and accuracy in isodose tuning. This article is protected by copyright. All rights reserved.
View details for DOI 10.1002/mp.15560
View details for PubMedID 35182074
-
A How-To Compendium for GammaPod Treatments, Clinical Workflow, and Clinical Program at an Early Adopting Institution.
Practical radiation oncology
2022
Abstract
Breast irradiation following breast-conserving surgery is an integral part of breast conserving therapy for curative treatment of early-stage breast cancer1-7. With the recognition that the majority of ipsilateral local relapses following breast-conserving therapy occur at the site of the tumor bed, several trials have since investigated the efficacy of accelerated partial-breast irradiation (APBI)8-10 as an alternative to the established but less convenient option of daily whole breast irradiation over several weeks. However, the setup uncertainty and inter-fraction movement expected with 3-dimensional conformal radiation therapy (3D-CRT) APBI has generally required the use of larger planning target volume margin expansions, which ultimately results in a larger dose to normal tissues, as well as an association with worsened cosmesis11-13. A stereotactic partial breast irradiation (S-PBI) approach is needed to allow more precise radiation therapy to the region of the primary tumor. As the GammaPod uses a vacuum assisted breast cup and pump, it allows for smaller CTV margins than 3D-CRT. Here, we describe our methods and workflow for efficient GammaPod S-PBI, as the second institution in the world to go live with GammaPod.
View details for DOI 10.1016/j.prro.2022.01.006
View details for PubMedID 35150897
-
Deep-learning and radiomics ensemble classifier for false positive reduction in brain metastases segmentation.
Physics in medicine and biology
1800
Abstract
Stereotactic radiosurgery (SRS) is now the standard of care for brain metastases (BMs) patients. The SRS treatment planning process requires precise target delineation, which in clinical workflow for patients with multiple (>4) BMs (mBMs) could become a pronounced time bottleneck. Our group has developed an automated BMs segmentation platform to assist in this process. The accuracy of the auto-segmentation, however, is influenced by the presence of false-positive segmentations, mainly caused by the injected contrast during MRI acquisition. To address this problem and further improve the segmentation performance, a deep-learning and radiomics ensemble classifier was developed to reduce the false-positive rate in segmentations. The proposed model consists of a Siamese network and a radiomic-based support vector machine (SVM) classifier. The 2D-based Siamese network contains a pair of parallel feature extractors with shared weights followed by a single classifier. This architecture is designed to identify the inter-class difference. On the other hand, the SVM model takes the radiomic features extracted from 3D segmentation volumes as the input for twofold classification, either a false-positive segmentation or a true BM. Lastly, the outputs from both models create an ensemble to generate the final label. The performance of the proposed model in the segmented mBMs testing dataset reached the accuracy (ACC), sensitivity (SEN), specificity (SPE) and area under the curve (AUC) of 0.91, 0.96, 0.90 and 0.93, respectively. After integrating the proposed model into the original segmentation platform, the average segmentation false negative rate (FNR) and the false positive over the union (FPoU) were 0.13 and 0.09, respectively, which preserved the initial FNR (0.07) and significantly improved the FPoU (0.55). The proposed method effectively reduced the false-positive rate in the BMs raw segmentations indicating that the integration of the proposed ensemble classifier into the BMs segmentation platform provides a beneficial tool for mBMs SRS management.
View details for DOI 10.1088/1361-6560/ac4667
View details for PubMedID 34952535
-
Dose kernel decomposition for spot-based radiotherapy treatment planning.
Medical physics
1800
Abstract
PURPOSE: Pre-calculation of accurate dose deposition kernels for treatment planning of spot-based radiotherapy, such as Gamma Knife (GK) and Gamma Pod (GP), can be very time consuming and may require large data storage with an enormous number of possible spots. We proposed a novel kernel decomposition (KD) model to address accurate and fast (real time) dose calculation with reduced data storage requirement for spot-based treatment planning. The application of KD model was demonstrated for clinical GK and GP radiotherapy platforms.METHODS: The dose deposition kernel at each spot (shot position) is modeled as the product of a shift-invariant kernel based on a reference kernel and spatially variant scale factor. The reference kernel, one for each collimator, is defined at the center of the commissioning phantom for GK and at the center of the treatment target for GP and calculated using the Monte Carlo (MC) method. The spatially variant scale factor is defined as the ratio of the mean tissue maximum ratio (TMR) at the candidate shot position to that at the reference kernel position; and the mean TMR map is calculated within the entire volume through parallel-beam ray tracing on the density image followed by averaging over all source directions. The proposed KD dose calculations were compared with the MC method and with the GK and GP treatment planning system (TPS) computations for various shot positions and collimator sizes utilizing a phantom and fourteen and twelve clinical plans for GK and GP, respectively.RESULTS: For the phantom study, the KD Gamma index (3%/1 mm) passing rates were greater than 99% (median 100%) relative to the MC doses, except for the shots close to the boundary. The passing rates dropped below 90% for 8 mm (16 mm) shots positioned within 1 cm (2 cm) of the boundary. For the clinical GK plans, the KD Gamma passing rates were greater than 99% (median 100%) compared to the MC and greater than 92% (median 99%) compared to the TPS. For the clinical GP plans, the KD Gamma passing rates were greater than 95% (median 98%) compared to the MC and greater than 91% (median 97%) compared to the TPS. The scale factors were calculated in sub-seconds with GPU implementation and only need to be calculated once before treatment plan optimization. The calculation of the dose kernel was also within sub-seconds without requiring beam-by-beam calculation commonly done in the TPS.CONCLUSION: The proposed model can provide accurate dose and enables real-time dose and derivative calculations by kernel shifting and scaling without pre-calculating or requiring large data storage for GK and GP dose deposition kernels during treatment planning. This model could be useful for spot-based radiotherapy treatment planning by allowing an efficient global fine search for optimal spots. This article is protected by copyright. All rights reserved.
View details for DOI 10.1002/mp.15415
View details for PubMedID 34932827
-
Saliency-guided deep learning network for automatic tumor bed volume delineation in post-operative breast irradiation.
Physics in medicine and biology
2021
Abstract
Efficient, reliable and reproducible target volume delineation is a key step in the effective planning of breast radiotherapy. However, post-operative breast target delineation is challenging as the contrast between the tumor bed volume (TBV) and normal breast tissue is relatively low in CT images. In this study, we propose to mimic the marker-guidance procedure in manual target delineation. We developed a saliency-based deep learning segmentation (SDL-Seg) algorithm for accurate TBV segmentation in post-operative breast irradiation. The SDL-Seg algorithm incorporates saliency information in the form of markers' location cues into a U-Net model. The design forces the model to encode the location-related features, which underscores regions with high saliency levels and suppresses low saliency regions. The saliency maps were generated by identifying markers on CT images. Markers' locations were then converted to probability maps using a distance-transformation coupled with a Gaussian filter. Subsequently, the CT images and the corresponding saliency maps formed a multi-channel input for the SDL-Seg network. Our in-house dataset was comprised of 145 prone CT images from 29 post-operative breast cancer patients, who received 5-fraction partial breast irradiation (PBI) regimen on GammaPod. The 29 patients were randomly split into training (19), validation (5) and test (5) sets. The performance of the proposed method was compared against basic U-Net. Our model achieved mean (standard deviation) of 76.4(±2.7) %, 6.76(±1.83) mm, and 1.9(±0.66) mm for DSC, HD95, and ASD respectively on the test set with computation time of below 11 seconds per one CT volume. SDL-Seg showed superior performance relative to basic U-Net for all the evaluation metrics while preserving low computation cost. The findings demonstrate that SDL-Seg is a promising approach for improving the efficiency and accuracy of the on-line treatment planning procedure of PBI, such as GammaPod based PBI.
View details for DOI 10.1088/1361-6560/ac176d
View details for PubMedID 34298539
-
A general algorithm for distributed treatments of multiple brain metastases
MEDICAL PHYSICS
2021: 1832–38
Abstract
Stereotactic radiosurgery (SRS) has become a primary treatment for multiple brain metastases (BM) but may require distribution of BMs over several sessions to make delivery time and radiation toxicity manageable. Contrasting to equal fraction dose in conventional fractionation, distributed SRS delivers full dose to a subset of BMs in each session while avoiding adjacent BMs in the same session to reduce toxicity from overlapping radiation. However, current clinical treatment planning for distributed SRS relies on manual BM assignment, which can be tedious and error prone. This work describes a novel approach to automate the distribution of BM in the Gamma Knife (GK) clinical workflow.We represent each BM as an electrostatic field of the same polarity that exerts repulsive forces on other BMs in the same session. This representation naturally leads to separation of close BMs into different sessions to lower the potential energy. Indeed, the BM distribution problem can be formulated as minimization of the total potential energy from all treatment sessions subject to delivery time constraints in mixed-integer quadratic programming (MIQP). We retrospectively studied eight clinical GK cases of multiple BM and compared the automated MIQP solution with clinically used BM distribution to demonstrate the efficacy of the proposed approach.With the problem size equal to the number of BMs times the number of sessions, this MIQP can be solved in a minute on a personal workstation. The MIQP solution effectively separated BMs for a given number of treatment sessions and evened out the delivery time distribution among sessions. Compared to the clinically used manual BM distributions in paired t-test for a similar range of delivery time variation, the automated BM distributions had lower energy objectives (range of decrease: [11% 89%]; median: 25%; P = . 073 ), more uniformly distributed treatment volumes (range of decrease for the normalized standard deviation of volume distribution: [0.02 0.95]; median: 0.16; P = . 013 ), more scattered BMs in each treatment session (range of increase for the mean minimum BM distance: [0 14] mm; median: 6 mm; P = . 008 ), and lower overall V 12 (range of decrease: [0.0 1.6] cc; median: 0.2 cc; P = . 052 ). Moreover, without distribution, that is, with all BMs treated in the same session, V 12 was substantially larger compared to both manual and automated BM distributions; the increase ranged from 0.1 to 16.6 cc with a median of 1.3 cc.The proposed approach models the clinical practice and provides an efficient solution for optimal selection of BM subsets for distributed SRS. Further evaluations are underway to establish this approach as a tool for improving clinical workflow and to facilitate systematic study on the benefits of distributed SRS treatments.
View details for DOI 10.1002/mp.14722
View details for Web of Science ID 000620296400001
View details for PubMedID 33449357
View details for PubMedCentralID PMC8058245
-
Cosmetic Outcomes of a Phase 1 Dose Escalation Study of 5-Fraction Stereotactic Partial Breast Irradiation for Early Stage Breast Cancer.
International journal of radiation oncology, biology, physics
2021
Abstract
PURPOSE: Our purpose was to evaluate cosmetic changes after 5-fraction adjuvant stereotactic partial breast irradiation (S-PBI).METHODS AND MATERIALS: Seventy-five women with in situ or invasive breast cancer stage 0, I, or II, with tumor size ≤3 cm, were enrolled after lumpectomy in a phase 1 dose escalation trial of S-PBI into cohorts receiving 30, 32.5, 35, 37.5, or 40 Gy in 5 fractions. Before S-PBI, 3 to 4 gold fiducial markers were placed in the lumpectomy cavity for tracking with the Synchrony respiratory tracking system. S-PBI was delivered with a CyberKnife robotic radiosurgery system. Patients and physicians evaluated global cosmesis using the Harvard Breast Cosmesis Scale. Eight independent panelists evaluated digital photography for global cosmesis and 10 subdomains at baseline and follow-up. McNemar tests were used to evaluate change in cosmesis, graded as excellent/good or fair/poor, from baseline to year 3. Wilcoxon signed rank tests were used to evaluate change in subdomains. Cohen's kappa (kappa) statistic was used to estimate interobserver agreement (IOA) between raters, and Fleiss' kappa was used to estimate IOA between panelists.RESULTS: Median cosmetic follow-up was 5, 5, 5, 4, and 3 years for the 30, 32.5, 35, 37.5, and 40 Gy cohorts. Most patients reported excellent/good cosmesis at both baseline (86.3%) and year 3 (89.8%). No dose cohort had significantly worsened cosmesis by year 3 on McNemar analysis. No cosmetic subdomain had significant worsening by year 3. IOA was fair for patient-physician (kappa = 0.300, P < .001), patient-panel (kappa = 0.295, P < .001), physician-panel (kappa = 0.256, P < .001), and individual panelists (Fleiss kappa = 0.327, P < .001).CONCLUSIONS: Dose escalation of S-PBI from 30 to 40 Gy in 5 fractions for early stage breast cancer was not associated with a detectable change in cosmesis by year 3. S-PBI is a promising modality for treatment of early stage breast cancer.
View details for DOI 10.1016/j.ijrobp.2021.01.015
View details for PubMedID 33476737
-
Preliminary Results of Multi-Institutional Phase I Dose Escalation Trial Using Single Fraction Stereotactic Partial Breast Irradiation for Early Stage Breast Cancer: Dose Escalated Single Fraction Stereotactic PBI.
International journal of radiation oncology, biology, physics
2021
Abstract
We report on our early experience of our prospective multi-center phase I dose escalation study of single fraction stereotactic partial breast irradiation (S-PBI) for early stage breast cancer after partial mastectomy using a robotic stereotactic radiation system.Thirty women with in situ or invasive breast cancer stage 0, I, or II with tumor size < 3 cm, treated with lumpectomy were enrolled to this phase 1 single fraction S-PBI dose escalation trial. Women received either 22.5 Gy, 26.5Gy, or 30 Gy in a single fraction using a robotic stereotactic radiation system. The primary outcome was to reach tumoricidal dose of 30Gy in single fraction to the lumpectomy cavity without exceeding the maximum tolerated dose (MTD). Secondary outcomes were to determine dose-limiting toxicity (DLT) and cosmesis. Tertiary goals were ipsilateral breast recurrence rate, distant disease-free interval, recurrence-free survival, and overall survival.From 6/2016 to 1/2021, 11, 8, and 10 patients were treated to doses of 22.5Gy, 26.5Gy, or 30Gy in a single fraction, respectively, with median follow-up being 47.9, 25.1, and 16.2 months. No patients experienced acute (<90 days) grade 3 or higher treatment-related toxicity and MTD was not reached. There were two delayed grade 3 toxicities. Four patients (13.8%) developed fat necrosis across all three cohorts, which compares favorably with results from other PBI trials. No dose cohort had a statistically significant cosmetic detriment from baseline to 12 months or 24 months follow-up by patient- or physician-reported global cosmetic scores. There were no reports of disease recurrence.This phase 1 trial demonstrates that S-PBI can be used to safely escalate dose to 30Gy in single fraction with low toxicity and without detriment in cosmesis relative to baseline.
View details for DOI 10.1016/j.ijrobp.2021.10.010
View details for PubMedID 34710523
-
Volumetric Modulated Arc Therapy Enabled Total Body Irradiation (VMAT-TBI): Six-year Clinical Experience and Treatment Outcomes.
Transplantation and cellular therapy
2021
Abstract
Total body irradiation is an important part of the conditioning regimens frequently used to prepare patients for allogeneic hematopoietic stem cell transplantation (SCT). Volumetric modulated arc therapy enabled total body irradiation (VMAT-TBI), an alternative to conventional TBI (cTBI), is a novel radiotherapy treatment technique that has been implemented and investigated in our institution.The purpose of this study is to 1) report our six-year clinical experience in terms of treatment planning strategy and delivery time, and 2) evaluate the clinical outcomes and toxicities in our cohort of patients treated with VMAT-TBI.This is a retrospective single center study. Forty-four patients at our institution received VMAT-TBI and chemotherapy conditioning followed by allogeneic stem cell transplant between 2014 and 2020. Thirty-two patients (73%) received standard-dose TBI (12-13.2 Gy in 6-8 fractions twice daily) while twelve (27%) received low-dose TBI (2-4 Gy in one fraction). Treatment planning, delivery, and treatment outcome data including overall survival (OS), relapse free survival (RFS), and toxicities were analyzed.The developed VMAT-TBI planning strategy consistently generated plans satisfying our dose constraints, with planning target volume (PTV) coverage >90%, mean lung dose (MLD) ∼50-75% of prescription dose, and minimal hotspots in critical organs. Most of the treatment deliveries were <100 minutes (range 33-147, mean 72). The median follow-up was 26 months. At the last follow up, 34 of 44 (77%) of patients were alive, with one- and two- year OS of 90% and 79% and RFS of 88% and 71%, respectively. The most common grade 3+ toxicities observed were mucositis (31 patients, 71%) and nephrotoxicity (6 patients, 13%), both of which were deemed multifactorial in etiology. Four patients (9%) in standard-dose cohort developed grade 3+ pneumonitis, with three cases in setting of documented respiratory infection and only one (2%) deemed likely related to radiation alone.VMAT-TBI provides a safe alternative to cTBI. The dose modulation capability of VMAT-TBI may lead to new treatment strategies, such as simultaneous boost and further critical organ sparing, for better malignant cell eradication, immune suppression, and lower toxicities.
View details for DOI 10.1016/j.jtct.2021.10.020
View details for PubMedID 34775145
-
Deep learning-based medical image segmentation with limited labels
PHYSICS IN MEDICINE AND BIOLOGY
2020; 65 (23)
Abstract
Deep learning (DL) based auto-segmentation has the potential for accurate organ delineation in radiotherapy applications but requires large amounts of clean labeled data to train a robust model. However, annotating medical images is extremely time-consuming and requires clinical expertise, especially for segmentation that demands voxel-wise labels. On the other hand, medical images without annotations are abundant and highly accessible. To alleviate the influence of the limited number of clean labels, we propose a weakly-supervised DL training approach using deformable image registration (DIR)-based annotations, leveraging the abundance of unlabeled data. We generate pseudo-contours by utilizing DIR to propagate atlas contours onto abundant unlabeled images and train a robust DL-based segmentation model. With 10 labeled TCIA dataset and 50 unlabeled CT scans from our institution, our model achieved Dice similarity coefficient of 87.9%, 73.4%, 73.4%, 63.2% and 61.0% on mandible, left & right parotid glands and left & right submandibular glands of TCIA test set and competitive performance on our institutional clinical dataset and a third party (PDDCA) dataset. Experimental results demonstrated the proposed method outperformed traditional multi-atlas DIR methods and fully-supervised limited data training and is promising for DL-based medical image segmentation application with limited annotated data.
View details for DOI 10.1088/1361-6560/abc363
View details for Web of Science ID 000618027800001
View details for PubMedID 33086205
View details for PubMedCentralID PMC8058113
-
Deep learning-based inverse mapping for fluence map prediction
PHYSICS IN MEDICINE AND BIOLOGY
2020; 65 (23)
Abstract
We developed a fluence map prediction method that directly generates fluence maps for a given desired dose distribution without optimization for volumetric modulated arc therapy (VMAT) planning. The prediction consists of two steps. First, projections of the desired dose are calculated and then inversely mapped to fluence maps in the phantom geometry by a deep neural network (DNN). Second, a plan scaling technique is applied to scale fluence maps from phantom to patient geometry. We evaluated the performance of the proposed fluence map prediction method for 102 head and neck (H&N) and 14 prostate cancer VMAT plans by comparing the patient doses calculated from the predicted fluence maps with the given desired dose distributions. The mean dose differences were 1.42%±0.37%, 1.53%±0.44% and 1.25%±0.44% for the planning target volume (PTV), the region from the PTV boundary to the 50% isodose line, and the region from the 50% to the 20% isodose line, respectively. The gamma passing rate was 98.06%±2.64% with the 3 mm/3% criterion. The prediction time for a single VMAT plan was less than one second. In conclusion, we developed an inverse mapping-based method that predicts fluence maps for desired dose distributions with high accuracy. Our method is effectively an optimization-free inverse planning approach, which was orders of magnitude faster than fluence map optimization (FMO). Combining the proposed method with leaf sequencing has the potential to dramatically speed up VMAT treatment planning.
View details for DOI 10.1088/1361-6560/abc12c
View details for Web of Science ID 000617566700001
View details for PubMedID 33053515
View details for PubMedCentralID PMC8044255
-
Risk Factors for Fat Necrosis After Stereotactic Partial Breast Irradiation for Early-Stage Breast Cancer in a Phase 1 Clinical Trial
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS
2020; 108 (3): 697–706
Abstract
This study reports predictive dosimetric and physiologic factors for fat necrosis after stereotactic-partial breast irradiation (S-PBI).Seventy-five patients with ductal carcinoma-in situ or invasive nonlobular epithelial histologies stage 0, I, or II, with tumor size <3 cm were enrolled in a dose-escalation, phase I S-PBI trial between January 2011 and July 2015. Fat necrosis was evaluated clinically at each follow-up. Treatment data were extracted from the Multiplan Treatment Planning System (Cyberknife, Accuray). Univariate and stepwise logistic regression analyses were conducted to identify factors associated with palpable fat necrosis.With a median follow-up of 61 months (range: 4.3-99.5 months), 11 patients experienced palpable fat necrosis, 5 cases of which were painful. The median time to development of fat necrosis was 12.7 months (range, 3-42 months). On univariate analyses, higher V32.5-47.5 Gy (P < .05) and larger breast volume (P < .01) were predictive of any fat necrosis; higher V35-50 Gy (P < .05), receiving 2 treatments on consecutive days (P = .02), and higher Dmax (P = .01) were predictive of painful fat necrosis. On multivariate analyses, breast volume larger than 1063 cm3 remained a predictive factor for any fat necrosis; receiving 2 treatments on consecutive days and higher V45 Gy were predictive of painful fat necrosis. Breast laterality, planning target volume (PTV), race, body mass index, diabetic status, and tobacco or drug use were not significantly associated with fat necrosis on univariate analysis.Early-stage breast cancer patients treated with breast conserving surgery and S-PBI in our study had a fat necrosis rate comparable to other accelerated partial breast irradiation modalities, but S-PBI is less invasive. To reduce risk of painful fat necrosis, we recommend not delivering fractions on consecutive days; limiting V42.5 < 50 cm3, V45 < 20 cm3, V47.5 < 1 cm3, Dmax ≤ 48 Gy and PTV < 100 cm3 when feasible; and counseling patients about the increased risk for fat necrosis when constraints are not met and for those with breast volume >1000 cm3.
View details for DOI 10.1016/j.ijrobp.2020.05.025
View details for Web of Science ID 000574862100026
View details for PubMedID 32464155
-
Robustness study of noisy annotation in deep learning based medical image segmentation
PHYSICS IN MEDICINE AND BIOLOGY
2020; 65 (17): 175007
Abstract
Partly due to the use of exhaustive-annotated data, deep networks have achieved impressive performance on medical image segmentation. Medical imaging data paired with noisy annotation are, however, ubiquitous, but little is known about the effect of noisy annotation on deep learning based medical image segmentation. We studied the effect of noisy annotation in the context of mandible segmentation from CT images. First, 202 images of head and neck cancer patients were collected from our clinical database, where the organs-at-risk were annotated by one of twelve planning dosimetrists. The mandibles were roughly annotated as the planning avoiding structure. Then, mandible labels were checked and corrected by a head and neck specialist to get the reference standard. At last, by varying the ratios of noisy labels in the training set, deep networks were trained and tested for mandible segmentation. The trained models were further tested on other two public datasets. Experimental results indicated that the network trained with noisy labels had worse segmentation than that trained with reference standard, and in general, fewer noisy labels led to better performance. When using 20% or less noisy cases for training, no significant difference was found on the segmentation results between the models trained by noisy or reference annotation. Cross-dataset validation results verified that the models trained with noisy data achieved competitive performance to that trained with reference standard. This study suggests that the involved network is robust to noisy annotation to some extent in mandible segmentation from CT images. It also highlights the importance of labeling quality in deep learning. In the future work, extra attention should be paid to how to utilize a small number of reference standard samples to improve the performance of deep learning with noisy annotation.
View details for DOI 10.1088/1361-6560/ab99e5
View details for Web of Science ID 000565759600001
View details for PubMedID 32503027
View details for PubMedCentralID PMC7567130
-
BIRADS features-oriented semi-supervised deep learning for breast ultrasound computer-aided diagnosis
PHYSICS IN MEDICINE AND BIOLOGY
2020; 65 (12): 125005
Abstract
We propose a novel BIRADS-SSDL network that integrates clinically-approved breast lesion characteristics (BIRADS features) into task-oriented semi-supervised deep learning (SSDL) for accurate diagnosis of ultrasound (US) images with a small training dataset. Breast US images are converted to BIRADS-oriented feature maps (BFMs) using a distance-transformation coupled with a Gaussian filter. Then, the converted BFMs are used as the input of an SSDL network, which performs unsupervised stacked convolutional auto-encoder (SCAE) image reconstruction guided by lesion classification. This integrated multi-task learning allows SCAE to extract image features with the constraints from the lesion classification task, while the lesion classification is achieved by utilizing the SCAE encoder features with a convolutional network. We trained the BIRADS-SSDL network with an alternative learning strategy by balancing the reconstruction error and classification label prediction error. To demonstrate the effectiveness of our approach, we evaluated it using two breast US image datasets. We compared the performance of the BIRADS-SSDL network with conventional SCAE and SSDL methods that use the original images as inputs, as well as with an SCAE that use BFMs as inputs. The experimental results on two breast US datasets show that BIRADS-SSDL ranked the best among the four networks, with a classification accuracy of around 94.23 ± 3.33% and 84.38 ± 3.11% on two datasets. In the case of experiments across two datasets collected from two different institutions/and US devices, the developed BIRADS-SSDL is generalizable across the different US devices and institutions without overfitting to a single dataset and achieved satisfactory results. Furthermore, we investigate the performance of the proposed method by varying the model training strategies, lesion boundary accuracy, and Gaussian filter parameters. The experimental results showed that a pre-training strategy can help to speed up model convergence during training but with no improvement of the classification accuracy on the testing dataset. The classification accuracy decreases as the segmentation accuracy decreases. The proposed BIRADS-SSDL achieves the best results among the compared methods in each case and has the capacity to deal with multiple different datasets under one model. Compared with state-of-the-art methods, BIRADS-SSDL could be promising for effective breast US computer-aided diagnosis using small datasets.
View details for DOI 10.1088/1361-6560/ab7e7d
View details for Web of Science ID 000542229100001
View details for PubMedID 32155605
-
POD-DOSI: A dedicated dosimetry system for GammaPod commissioning and quality assurance
MEDICAL PHYSICS
2020; 47 (8): 3647–57
Abstract
GammaPod, a stereotactic partial breast irradiator allowing highly conformal radiation dose delivery, has its unique mechanical design and treatment planning system (TPS). However, the uniqueness of the system poses challenges regarding initial GammaPod system commissioning and routine quality assurance (QA). In this study, we report POD-DOSI, a dedicated dosimetry system for accurate and efficient commissioning and QA of GammaPod.The POD-DOSI system consists of two subsystems, POD-Scanner and POD-Calculator. The POD-Scanner is an automatic ion-chamber positioning system driven by two translational stepper motors for anterior-posterior, longitudinal, and lateral beam scanning. The stepper motors are controlled by a microcomputer through an in-house-developed graphical user interface, which can be remotely accessed by a laptop via wireless connection. The POD-Calculator is a commissioned GPU-based Monte Carlo dose calculation engine, which calculates dose by transporting particles from phase space constructed for GammaPod. In our institution, the POD-DOSI system was used for GammaPod TPS commissioning and dose verification. The POD-Calculator was further developed as a secondary dose calculation tool performing patient-specific plan QA before each treatment.The POD-DOSI system has been fully evaluated and tested, both mechanically and dosimetrically, and applied successfully to drive the commissioning of our GammaPod system. The POD-Scanner achieved 0.1 mm accuracy in ion-chamber positioning tests. The POD-Calculator generated dose profiles matched well with water phantom measurements and TPS calculations to <0.5 mm accuracy. For end-to-end test on 56 different treatment plans, in-water point dose measurements by POD-Scanner were within ±2.20% of the doses calculated by POD-Calculator (range: -2.01% to 2.20%, mean: 0.04%, std_dev: 1.10%). Correspondingly, when switching the calculation medium from water to breast tissue, the point doses calculated by the POD-Calculator were within ±1.60% of the point doses calculated by the GammaPOD TPS (range: -1.59% to 1.51%, mean: -0.02%, std_dev: 0.73%). The average three-dimensional gamma passing rate between the GammaPod TPS doses and the POD-Calculator doses was 97.10% under the 2%/1 mm gamma criteria. The POD-DOSI system substantially shortened the GammaPod dosimetry commissioning time from weeks to days.The developed POD-DOSI system resolves the challenges and streamlines the process of GammaPod commissioning and QA. It improves the efficiency and accuracy for both GammaPod commissioning and routine patient-specific QA.
View details for DOI 10.1002/mp.14221
View details for Web of Science ID 000535190500001
View details for PubMedID 32367556
-
A web-based brain metastases segmentation and labeling platform for stereotactic radiosurgery
MEDICAL PHYSICS
2020; 47 (8): 3263–76
Abstract
Stereotactic radiosurgery (SRS) has become a standard of care for patients' with brain metastases (BMs). However, the manual multiple BMs delineation can be time-consuming and could create an efficiency bottleneck in SRS workflow. There is a clinical need for automatic delineation and quantitative evaluation tools. In this study, building on our previous developed deep learning-based segmentation algorithms, we developed a web-based automated BMs segmentation and labeling platform to assist the SRS clinical workflow.This platform was developed based on the Django framework, including a web client and a back-end server. The web client enables interactions as database access, data import, and image viewing. The server performs the segmentation and labeling tasks including: skull stripping; deep learning-based BMs segmentation; and affine registration-based BMs labeling. Additionally, the client can display BMs contours with corresponding atlas labels, and allows further postprocessing tasks including: (a) adjusting window levels; (b) displaying/hiding specific contours; (c) removing false-positive contours; (d) exporting contours as DICOM RTStruct files; etc. RESULTS: We evaluated this platform on 10 clinical cases with BMs number varied from 12-81 per case. The overall operation took about 4-5 min per patient. The segmentation accuracy was evaluated between the manual contour and automatic segmentation with several metrics. The averaged center of mass shift was 1.55 ± 0.36 mm, the Hausdorff distance was 2.98 ± 0.63 mm, the mean of surface-to-surface distance (SSD) was 1.06 ± 0.31 mm, and the standard deviation of SSD was 0.80 ± 0.16 mm. In addition, the initial averaged false-positive over union (FPoU) and false-negative rate (FNR) were 0.43 ± 0.19 and 0.15 ± 0.10 respectively. After case-specific postprocessing, the averaged FPoU and FNR were 0.19 ± 0.10 and 0.15 ± 0.10 respectively.The evaluated web-based BMs segmentation and labeling platform can substantially improve the clinical efficiency compared to manual contouring. This platform can be a useful tool for assisting SRS treatment planning and treatment follow-up.
View details for DOI 10.1002/mp.14201
View details for Web of Science ID 000534819700001
View details for PubMedID 32333797
View details for PubMedCentralID PMC7567132
-
Radiation Therapy for Pediatric Brain Tumors using Robotic Radiation Delivery System and Intensity Modulated Proton Therapy
PRACTICAL RADIATION ONCOLOGY
2020; 10 (3): E173–E182
Abstract
This study recruited 2 centers with expertise in treating pediatric brain tumors with robotic radiation delivery system photon therapy and proton therapy, respectively, to study the plan quality and dose deposition characteristics of robotic radiation delivery system photon therapy and intensity modulated proton therapy (IMPT) plans.A total of 18 patients clinically treated with the robotic radiation delivery system were planned with IMPT. Cases were planned per the standard of care of each institution but respected the same planning objectives. The comparison included 3 aspects: plan quality, dose fall-off characteristics around the target volume, and the volume of the high-, intermediate-, and low-dose baths.All robotic radiation delivery system and IMPT plans met the planning objectives. However, IMPT significantly reduced the maximum dose to organs at risk away from the planning target volume (PTV), such as the cochlea and eye (P < .05), and the mean dose to the normal brain (P < .05). No statistically significant difference was observed in the maximum dose to the optical pathway and brain stem. Robotic radiation delivery system plans demonstrated a sharper dose fall-off within 5 mm around the PTV (P < .05), whereas IMPT significantly lowered the dose to the normal tissue beyond 10 mm from the PTV (P < .05). The robotic radiation delivery system offers a smaller high-dose bath whereas IMPT offers a smaller low-dose bath (P < .05). However, the difference in intermediate dose is not statistically significant.In general, robotic radiation delivery system plans exhibit reduced high-dose exposure to normal tissue, and IMPT plans have considerably smaller volumes of low-dose exposure with differences in medium-range dose baths increasingly favoring protons as tumor size increases.
View details for DOI 10.1016/j.prro.2019.09.008
View details for Web of Science ID 000534515800008
View details for PubMedID 31542454
-
Electron modulated arc therapy (EMAT) using photon MLC for postmastectomy chest wall treatment I: Monte Carlo-based dosimetric characterizations
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS
2019; 67: 1–8
Abstract
To study the dosimetric properties of electron arc beams delivered by photon-beam multi-leaf collimators (pMLC) in electron modulated arc therapy (EMAT) for postmastectomy chest wall treatments.Using the Monte Carlo method, we simulated a 2100EX Varian linear accelerator and verified the beam models in a water tank. Dosimetric characterizations were performed on cylindrical water phantoms of elliptical bases with various field sizes, arc ranges and source-to-surface distances (SSDs) for 6, 9 and 12 MeV beam energy.The arc beam has a higher bremsstrahlung dose than the static beam at the isocenter due to crossfire, but choosing a field size greater than 5 cm effectively reduces the bremsstrahlung dose. The depths of the 90% maximum dose located at 1.7, 2.8 and 4.1 cm for 6, 9 and 12 MeV, respectively, are similar to those of the static beams and independent of the field size and arc range.Based on the study, we recommend using the 5 cm field width for electron arc beams considering both bremsstrahlung dose at the isocenter and the arc profile penumbra. To ensure sufficient PTV edge coverage, we recommend a field length extension of at least 4 cm from PTV's edge for all beam energies and an arc extension of around 7°, 5°, and 5° for beam energies 6, 9, and 12 MeV, respectively. These dosimetric characterizations are the basis of pMLC-delivered EMAT treatment planning for postmastectomy chest wall patients.
View details for DOI 10.1016/j.ejmp.2019.10.018
View details for Web of Science ID 000503163400001
View details for PubMedID 31606657
View details for PubMedCentralID PMC6925626
-
Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy
PHYSICS IN MEDICINE AND BIOLOGY
2019; 64 (12): 125002
Abstract
Throughout the course of delivering a radiation therapy treatment, which may take several weeks, a patient's anatomy may change drastically, and adaptive radiation therapy (ART) may be needed. Cone-beam computed tomography (CBCT), which is often available during the treatment process, can be used for both patient positioning and ART re-planning. However, due to the prominent amount of noise, artifacts, and inaccurate Hounsfield unit (HU) values, the dose calculation based on CBCT images could be inaccurate for treatment planning. One way to solve this problem is to convert CBCT images to more accurate synthesized CT (sCT) images. In this work, we have developed a cycle-consistent generative adversarial network framework (CycleGAN) to synthesize CT images from CBCT images. This model is capable of image-to-image translation using unpaired CT and CBCT images in an unsupervised learning setting. The sCT images generated from CBCT through this CycleGAN model are visually and quantitatively similar to real CT images with decreased mean absolute error (MAE) from 69.29 HU to 29.85 HU for head-and-neck (H&N) cancer patients. The dose distributions calculated on the sCT by CycleGAN demonstrated a higher accuracy than those on CBCT in a 3D gamma index analysis with increased gamma index pass rate from 86.92% to 96.26% under 1 mm/1% criteria, when using the deformed planning CT image (dpCT) as the reference. We also compared the CycleGAN model with other unsupervised learning methods, including deep convolutional generative adversarial networks (DCGAN) and progressive growing of GANs (PGGAN), and demonstrated that CycleGAN outperformed the other two models. A phantom study has been conducted to compare sCT with dpCT, and the increase of structural similarity index from 0.91 to 0.93 shows that CycleGAN performed better than DIR in terms of preserving anatomical accuracy.
View details for DOI 10.1088/1361-6560/ab22f9
View details for Web of Science ID 000471166400002
View details for PubMedID 31108465
-
A feasibility study for predicting optimal radiation therapy dose distributions of prostate cancer patients from patient anatomy using deep learning
SCIENTIFIC REPORTS
2019; 9: 1076
Abstract
With the advancement of treatment modalities in radiation therapy for cancer patients, outcomes have improved, but at the cost of increased treatment plan complexity and planning time. The accurate prediction of dose distributions would alleviate this issue by guiding clinical plan optimization to save time and maintain high quality plans. We have modified a convolutional deep network model, U-net (originally designed for segmentation purposes), for predicting dose from patient image contours of the planning target volume (PTV) and organs at risk (OAR). We show that, as an example, we are able to accurately predict the dose of intensity-modulated radiation therapy (IMRT) for prostate cancer patients, where the average Dice similarity coefficient is 0.91 when comparing the predicted vs. true isodose volumes between 0% and 100% of the prescription dose. The average value of the absolute differences in [max, mean] dose is found to be under 5% of the prescription dose, specifically for each structure is [1.80%, 1.03%](PTV), [1.94%, 4.22%](Bladder), [1.80%, 0.48%](Body), [3.87%, 1.79%](L Femoral Head), [5.07%, 2.55%](R Femoral Head), and [1.26%, 1.62%](Rectum) of the prescription dose. We thus managed to map a desired radiation dose distribution from a patient's PTV and OAR contours. As an additional advantage, relatively little data was used in the techniques and models described in this paper.
View details for DOI 10.1038/s41598-018-37741-x
View details for Web of Science ID 000457287000064
View details for PubMedID 30705354
View details for PubMedCentralID PMC6355802
-
A recursive ensemble organ segmentation (REOS) framework: application in brain radiotherapy
PHYSICS IN MEDICINE AND BIOLOGY
2019; 64 (2): 025015
Abstract
The aim of this work is to develop a novel recursive ensemble OARs segmentation (REOS) framework for accurate organs-at-risk (OARs) automatic segmentation. The REOS recursively segment individual OARs by ensembling images features extracted from an organ localization module and a contour detection module. Both modules are based on a 3D U-Net architecture. The organ localization module is trained for rough segmentation to localize a region of interest (ROI) that encompasses the to-be-delineated OAR, while the contour detection module is trained to segment the OAR within the identified ROI. In this study, the developed REOS framework is applied for brain radiotherapy on segmenting six OARs including the eyes, the brainstem (BS), the optical nerves and the chiasm. Eighty T1-weighted magnetic resonance images (MRI) from 80 brain cancer patients' cases with OARs' gold standard contours were collected for training and testing REOS. On 20 testing cases, the REOS achieve a high segmentation accuracy with Dice similarity coefficient (DSC) mean and standard deviation of 93.9% ± 1.4%, 94.5% ± 2.0%, 90.6% ± 2.7%, on the left and right eyes and the BS, respectively. On small and segmentation-challenging organs, the left and right optical nerves and the chiasm, the REOS achieves DSC of 78.0% ± 10.5%, 82.2% ± 5.9% and 71.1% ± 9.1%. The satisfactory performances demonstrated the effectiveness of the REOS in OARs segmentation.
View details for DOI 10.1088/1361-6560/aaf83c
View details for Web of Science ID 000455823300012
View details for PubMedID 30540975
-
Flattening filter free in intensity-modulated radiotherapy (IMRT) - Theoretical modeling with delivery efficiency analysis
MEDICAL PHYSICS
2019; 46 (1): 34–44
Abstract
The flattening filter (FF) has traditionally been used to flatten beams or create uniform fields in conformal and intensity-modulated radiation therapy (IMRT) but reduces the dose rate. Many studies have confirmed improvement in delivery efficiency by removing the FF, also known as flattening filter free (FFF), especially for small field stereotactic body radiation therapy (SBRT); but it is unclear if large treatment fields still favor the FFF beam. We propose a novel, unified approach to quantify delivery efficiency of the FFF and flattened beams.We modeled the FF effect by inverse conical filters and systematically studied delivery efficiency (beam-on time, BOT) by varying the filter thickness, including the FF and FFF mode. We formulated the BOT of different beams for any arbitrary fluence map in linear programming to solve the optimal inverse conical filter that minimizes the BOT. One-dimensional optimal filters of minimum BOT were also derived in closed form for conical fluence to gain insight for arbitrary clinical fluence maps. We evaluated the BOT of the FFF beam and flattened beam for conformal treatment fields of various dimensions ranging from 5 cm × 5 cm to 25 cm × 25 cm. We also analyzed the BOT for 698 clinical IMRT prostate fluence maps of field size 10 cm × 10 cm, 17 head-and-neck fluence maps of field size 15 cm × 15 cm, and additional realistic test data from 90° rotation and up to 40 cm × 40 cm enlargement of these clinical fluence maps, which were all initially generated with flattened beams.The FFF beam minimized the BOT for A field size less than 20 cm in single leaf pair cases and for conformal fields of dimension less than 20 cm × 20 cm. The FFF beam also minimized the BOT for all tested prostate and head-and-neck cases. The median BOT ratios of the FFF beam to the flattened beam were 0.56 and 0.61 for prostate and head-and-neck cases, respectively. The FFF beam minimized the BOT for field size up to 30 cm × 30 cm and had similar BOTs to those of the flattened beam for field size greater than 30 cm × 30 cm in those clinically realistic test data.The filter modeling and BOT calculation enable us to quantify delivery efficiency of the FFF beam and flattened beam in a unified approach. The FFF beam minimized the BOT both theoretically and in simulations for all clinically relevant field sizes and fluence maps in IMRT. The results for conformal fields imply that the FFF beam requires less BOT than the flattened beam for volumetric modulated arc therapy (VMAT) treatments. The delivery efficiency consideration favors the FFF beam in intensity-modulated treatments and may eventually lead to removal of the FF in all future linear accelerator head designs.
View details for DOI 10.1002/mp.13267
View details for Web of Science ID 000455029900006
View details for PubMedID 30371944
-
Deep-learning based surface region selection for deep inspiration breath hold (DIBH) monitoring in left breast cancer radiotherapy
PHYSICS IN MEDICINE AND BIOLOGY
2018; 63 (24): 245013
Abstract
Deep inspiration breath hold (DIBH) with surface supervising is a common technique for cardiac dose reduction in left breast cancer radiotherapy. Surface supervision accuracy relies on the characteristics of surface region. In this study, a convolutional neural network (CNN) based automatic region-of-interest (ROI) selection method was proposed to select an optimal surface ROI for DIBH surface monitoring. The curvature entropy and the normal of each vertex on the breast cancer patient surface were calculated and formed as representative maps for ROI selection learning. 900 ROIs were randomly extracted from each patient's surface representative map, and the corresponding rigid ROI registration errors (REs) were calculated. The VGG-16 (a 16-layer network structure developed by Visual Geometry Group(VGG) from University of Oxford) pre-trained on a large natural image database ImageNet were fine-tuned using 27 thousand extracted ROIs and the corresponding REs from thirty patients. The RE prediction accuracy of the trained model was validated on additional ten patients. Satisfactory RE predictive accuracies were achieved with the root mean square error (RMSE)/mean absolute error (MAE) smaller than 1 mm/0.7 mm in translations and 0.45°/0.35° in rotations, respectively. The REs of the model selected ROIs on ten testing cases is close to the minimal predicted RE with mean RE differences <1 mm and <0.5° for translation and rotation, respectively. The proposed RE predictive model can be utilized for selecting a quasi-optimal ROI in left breast cancer DIBH radiotherapy (DIBH-RT).
View details for DOI 10.1088/1361-6560/aaf0d6
View details for Web of Science ID 000453061000004
View details for PubMedID 30523967
-
Investigating rectal toxicity associated dosimetric features with deformable accumulated rectal surface dose maps for cervical cancer radiotherapy
RADIATION ONCOLOGY
2018; 13: 125
Abstract
Better knowledge of the dose-toxicity relationship is essential for safe dose escalation to improve local control in cervical cancer radiotherapy. The conventional dose-toxicity model is based on the dose volume histogram, which is the parameter lacking spatial dose information. To overcome this limit, we explore a comprehensive rectal dose-toxicity model based on both dose volume histogram and dose map features for accurate radiation toxicity prediction.Forty-two cervical cancer patients treated with combined external beam radiotherapy (EBRT) and brachytherapy (BT) were retrospectively studied, including 12 with Grade ≥ 2 rectum toxicity and 30 patients with Grade 0-1 toxicity (non-toxicity patients). The cumulative equivalent 2-Gy rectal surface dose was deformably summed using the deformation vector fields obtained through a recent developed local topology preserved non-rigid point matching algorithm. The cumulative three-dimensional (3D) dose was flattened and mapped to a two-dimensional (2D) plane to obtain the rectum surface dose map (RSDM). The dose volume parameters (DVPs) were calculated from the 3D rectum surface, while the texture features and the dose geometric parameters (DGPs) were extracted from the 2D RSDM. Representative features further computed from DVPs, textures and DGPs by principle component analysis (PCA) and statistical analysis were respectively fed into a support vector machine equipped with a sequential feature selection procedure. The predictive powers of the representative features were compared with the GEC-ESTRO dosimetric parameters D0.1/1/2cm3.Satisfactory predictive accuracy of sensitivity 74.75 and 84.75%, specificity 72.67 and 79.87%, and area under the receiver operating characteristic curve (AUC) 0.82 and 0.91 were respectively achieved by the PCA features and statistical significant features, which were superior to the D0.1/1/2cm3 (AUC 0.71). The relative area in dose levels of 64Gy, 67Gy, 68Gy, 87Gy, 88Gy and 89Gy, perimeters in dose levels of 89Gy, as well as two texture features were ranked as the important factors that were closely correlated with rectal toxicity.Our extensive experimental results have demonstrated the feasibility of the proposed scheme. A future large patient cohort study is still needed for model validation.
View details for DOI 10.1186/s13014-018-1068-0
View details for Web of Science ID 000437974400001
View details for PubMedID 29980214
View details for PubMedCentralID PMC6035458
-
Use of 5-alpha-reductase inhibitors as alternatives to luteinizing-hormone releasing hormone (LHRH) analogs or anti-androgens for prostate downsizing before brachytherapy
PRACTICAL RADIATION ONCOLOGY
2018; 8 (3): E167–E174
Abstract
Custom tissue compensators provide dosimetric advantages for treating superficial or complex anatomy, but currently available fabrication technology is expensive or impractical for most clinical operations and yields compensators that are difficult for patients to tolerate. We aimed to develop an inexpensive, clinically feasible workflow for generating patient-specific, soft, custom silicone boluses (SCSBs) for head-and-neck (HN) radiation therapy.We developed a method using 3-dimensional printed parts for generating SCSBs for the treatment of HN cancers. The clinical workflow for generation of SCSBs was characterized inclusive of patient simulation to treatment in terms of resource time and cost. Dosimetric properties such as percentage depth dose and dose profiles were measured for SCSBs using GaF films. Comprehensive measurements were also conducted on an HN phantom. SCSBs were generated and used for electron or photon based radiation treatments of 7 HN patients with lesions at nose, cheek, eye, or ears. In vivo dose measurements with optically simulated luminescence dosimeters were performed.Total design and fabrication time from patient simulation to radiation treatment start required approximately 1 week, with fabrication constituting 1 to 2 working days depending on bolus surface area, volume, and complexity. Computed tomography and dosimetric properties of the soft bolus were similar to water. In vivo dose measurements on 7 treated patients confirmed that the dose deposition conformed to planned doses. Material costs were lower than currently available hard plastic boluses generated with 3-dimensional printing technology. All treated patients tolerated SCSBs for the duration of therapy.Generation and use of SCSBs for clinical use is feasible and effective for the treatment of HN cancers.
View details for DOI 10.1016/j.prro.2017.11.001
View details for Web of Science ID 000432348600011
View details for PubMedID 29452869
-
Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept
PHYSICS IN MEDICINE AND BIOLOGY
2018; 63 (5): 055004
Abstract
Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects' diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.
View details for DOI 10.1088/1361-6560/aaad1f
View details for Web of Science ID 000426580100001
View details for PubMedID 29405123
-
Internal Motion Estimation by Internal-external Motion Modeling for Lung Cancer Radiotherapy
SCIENTIFIC REPORTS
2018; 8: 3677
Abstract
The aim of this study is to develop an internal-external correlation model for internal motion estimation for lung cancer radiotherapy. Deformation vector fields that characterize the internal-external motion are obtained by respectively registering the internal organ meshes and external surface meshes from the 4DCT images via a recently developed local topology preserved non-rigid point matching algorithm. A composite matrix is constructed by combing the estimated internal phasic DVFs with external phasic and directional DVFs. Principle component analysis is then applied to the composite matrix to extract principal motion characteristics, and generate model parameters to correlate the internal-external motion. The proposed model is evaluated on a 4D NURBS-based cardiac-torso (NCAT) synthetic phantom and 4DCT images from five lung cancer patients. For tumor tracking, the center of mass errors of the tracked tumor are 0.8(±0.5)mm/0.8(±0.4)mm for synthetic data, and 1.3(±1.0)mm/1.2(±1.2)mm for patient data in the intra-fraction/inter-fraction tracking, respectively. For lung tracking, the percent errors of the tracked contours are 0.06(±0.02)/0.07(±0.03) for synthetic data, and 0.06(±0.02)/0.06(±0.02) for patient data in the intra-fraction/inter-fraction tracking, respectively. The extensive validations have demonstrated the effectiveness and reliability of the proposed model in motion tracking for both the tumor and the lung in lung cancer radiotherapy.
View details for DOI 10.1038/s41598-018-22023-3
View details for Web of Science ID 000426151800010
View details for PubMedID 29487330
View details for PubMedCentralID PMC5829085
-
Predicting severe hematologic toxicity from extended-field chemoradiation of para-aortic nodal metastases from cervical cancer
PRACTICAL RADIATION ONCOLOGY
2018; 8 (1): 13–19
Abstract
The purpose of this study was to determine factors predictive for severe hematologic toxicity (HT) in cervical cancer patients with para-aortic lymph node metastasis treated with concurrent cisplatin chemoradiation to an extended field (EFCRT).Thirty-eight patients with cervical cancer and para-aortic lymph node metastasis who underwent EFCRT were analyzed. Active bone marrow was defined as the region within irradiated total bone marrow (BMTOT) with a standard uptake value on 18F-fluorodeoxyglucose positron emission tomography/computed tomography greater than the mean standard uptake value for BMTOT. Serial weekly blood counts from the beginning to the end of radiation treatment were evaluated for HT using Common Terminology Criteria for Adverse Events, version 4.0.Nineteen patients had grade 3 or higher hematologic toxicity (HT3+), not including lymphocyte toxicity. Obese patients (n = 12) were less likely to get HT3+ (P = .03) despite getting equivalent doses of chemotherapy. Volumes of BMTOT and active bone marrow receiving doses of 20, 30, and 45 Gy and body mass index significantly predicted HT3+. Patients who had HT3+ had prolonged treatment time (62 vs 53 days, P < .001).For patients receiving EFCRT, bone marrow irradiation parameters and patient body mass index were associated with HT3+. A simplified nomogram has been created to predict HT3+ in these patients, allowing the potential to explore bone marrow-sparing delivery techniques.
View details for DOI 10.1016/j.prro.2017.07.001
View details for Web of Science ID 000419077100006
View details for PubMedID 28865761
-
Deep convolutional neural network with transfer learning for rectum toxicity prediction in cervical cancer radiotherapy: a feasibility study
PHYSICS IN MEDICINE AND BIOLOGY
2017; 62 (21): 8246–63
Abstract
Better understanding of the dose-toxicity relationship is critical for safe dose escalation to improve local control in late-stage cervical cancer radiotherapy. In this study, we introduced a convolutional neural network (CNN) model to analyze rectum dose distribution and predict rectum toxicity. Forty-two cervical cancer patients treated with combined external beam radiotherapy (EBRT) and brachytherapy (BT) were retrospectively collected, including twelve toxicity patients and thirty non-toxicity patients. We adopted a transfer learning strategy to overcome the limited patient data issue. A 16-layers CNN developed by the visual geometry group (VGG-16) of the University of Oxford was pre-trained on a large-scale natural image database, ImageNet, and fine-tuned with patient rectum surface dose maps (RSDMs), which were accumulated EBRT + BT doses on the unfolded rectum surface. We used the adaptive synthetic sampling approach and the data augmentation method to address the two challenges, data imbalance and data scarcity. The gradient-weighted class activation maps (Grad-CAM) were also generated to highlight the discriminative regions on the RSDM along with the prediction model. We compare different CNN coefficients fine-tuning strategies, and compare the predictive performance using the traditional dose volume parameters, e.g. D 0.1/1/2cc, and the texture features extracted from the RSDM. Satisfactory prediction performance was achieved with the proposed scheme, and we found that the mean Grad-CAM over the toxicity patient group has geometric consistence of distribution with the statistical analysis result, which indicates possible rectum toxicity location. The evaluation results have demonstrated the feasibility of building a CNN-based rectum dose-toxicity prediction model with transfer learning for cervical cancer radiotherapy.
View details for DOI 10.1088/1361-6560/aa8d09
View details for Web of Science ID 000413137000004
View details for PubMedID 28914611
-
A deep convolutional neural network-based automatic delineation strategy for multiple brain metastases stereotactic radiosurgery
PLOS ONE
2017; 12 (10): e0185844
Abstract
Accurate and automatic brain metastases target delineation is a key step for efficient and effective stereotactic radiosurgery (SRS) treatment planning. In this work, we developed a deep learning convolutional neural network (CNN) algorithm for segmenting brain metastases on contrast-enhanced T1-weighted magnetic resonance imaging (MRI) datasets. We integrated the CNN-based algorithm into an automatic brain metastases segmentation workflow and validated on both Multimodal Brain Tumor Image Segmentation challenge (BRATS) data and clinical patients' data. Validation on BRATS data yielded average DICE coefficients (DCs) of 0.75±0.07 in the tumor core and 0.81±0.04 in the enhancing tumor, which outperformed most techniques in the 2015 BRATS challenge. Segmentation results of patient cases showed an average of DCs 0.67±0.03 and achieved an area under the receiver operating characteristic curve of 0.98±0.01. The developed automatic segmentation strategy surpasses current benchmark levels and offers a promising tool for SRS treatment planning for multiple brain metastases.
View details for DOI 10.1371/journal.pone.0185844
View details for Web of Science ID 000412493000011
View details for PubMedID 28985229
View details for PubMedCentralID PMC5630188
-
Inversed-Planned Respiratory Phase Gating in Lung Conformal Radiation Therapy
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS
2017; 99 (2): 317–24
Abstract
To assess whether the optimal gating window for each beam during lung radiation therapy with respiratory gating will be dependent on a variety of patient-specific factors, such as tumor size and location and the extent of relative tumor and organ motion.To create optimal gating treatment plans, we started from an optimized clinical plan, created a plan per respiratory phase using the same beam arrangements, and used an inverse planning optimization approach to determine the optimal gating window for each beam and optimal beam weights (ie, monitor units). Two pieces of information were used for optimization: (1) the state of the anatomy at each phase, extracted from 4-dimensional computed tomography scans; and (2) the time spent in each state, estimated from a 2-minute monitoring of the patient's breathing motion. We retrospectively studied 15 lung cancer patients clinically treated by hypofractionated conformal radiation therapy, for whom 45 to 60 Gy was administered over 3 to 15 fractions using 7 to 13 beams. Mean gross tumor volume and respiratory-induced tumor motion were 82.5 cm3 and 1.0 cm, respectively.Although patients spent most of their respiratory cycle in end-exhalation (EE), our optimal gating plans used EE for only 34% of the beams. Using optimal gating, maximum and mean doses to the esophagus, heart, and spinal cord were reduced by an average of 15% to 26%, and the beam-on times were reduced by an average of 23% compared with equivalent single-phase EE gated plans (P<.034, paired 2-tailed t test).We introduce a personalized respiratory-gating technique in which inverse planning optimization is used to determine patient- and beam-specific gating phases toward enhancing dosimetric quality of radiation therapy treatment plans.
View details for DOI 10.1016/j.ijrobp.2017.05.039
View details for Web of Science ID 000408690000019
View details for PubMedID 28871981
View details for PubMedCentralID PMC5656395
-
Comprehensive target geometric errors and margin assessment in stereotactic partial breast irradiation
RADIATION ONCOLOGY
2017; 12: 151
Abstract
Recently developed stereotactic partial breast irradiation (S-PBI) allows delivery of a high biologically potent dose to the target while sparing adjacent critical organs and normal tissue. With S-PBI tumoricidal doses, accurate and precise dose delivery is critical to achieve high treatment quality. This study is to investigate both rigid and non-rigid components of target geometric error and their corresponding margins in S-PBI and identify correlated clinical factors.Forty-three early-stage breast cancer patients with implanted gold fiducial markers were enrolled in the study. Fiducial positions recorded on the orthogonal kV images on a Cyberknife system during treatment were used to estimate intra-fraction errors and composite errors (including intra-fraction errors and residual errors after patient setup). Both rigid and non-rigid components of intra-fraction and composite errors were analyzed and used to estimate rigid and non-rigid margins, respectively. Univariate and multivariate linear regressions were conducted to evaluate correlations between clinical factors and errors.For the study group, the intra-fraction rigid and non-rigid errors are 2.0 ± 0.6 mm and 0.3 ± 0.2 mm, respectively. The composite rigid and non-rigid errors are 2.3 ± 0.5 mm and 1.3 ± 0.8 mm, respectively. The rigid margins in the left-right, anterior-posterior, and superior-inferior directions are estimated as 2.1, 2.4, and 2.3 mm, respectively. The estimated non-rigid margin, assumed to be isotropic, is 1.7 mm. The outer breast quadrants are more susceptible to composite errors occurrence than the inner breast quadrants. The target to chest wall distance is the clinical factor correlated with target geometric errors.This is the first comprehensive analysis of breast target geometric rigid and non-rigid errors in S-PBI. Upon the estimation, the non-rigid margin is comparable to rigid margin, and therefore should be included in planning target volume as it cannot be accounted for by the Cyberknife system. Treatment margins selection also need to consider the impact of relevant clinical factor.
View details for DOI 10.1186/s13014-017-0889-6
View details for Web of Science ID 000410314600001
View details for PubMedID 28893302
View details for PubMedCentralID PMC5594509
-
An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
MEDICAL PHYSICS
2017; 44 (6): 2369–78
Abstract
To design and construct a three-dimensional (3D) anthropomorphic abdominal phantom for geometric accuracy and dose summation accuracy evaluations of deformable image registration (DIR) algorithms for adaptive radiation therapy (ART).Organ molds, including liver, kidney, spleen, stomach, vertebra, and two metastasis tumors, were 3D printed using contours from an ovarian cancer patient. The organ molds were molded with deformable gels made of different mixtures of polyvinyl chloride (PVC) and the softener dioctyl terephthalate. Gels with different densities were obtained by a polynomial fitting curve that described the relation between the Hounsfield unit (HU) and PVC-softener blending ratio. The rigid vertebras were constructed by molding of white cement and cellulose pulp. The final abdominal phantom was assembled by arranging all the fabricated organs inside a hollow dummy according to their anatomies, and sealed by deformable gel with averaged HU of muscle and fat. Fiducial landmarks were embedded inside the phantom for spatial accuracy and dose accumulation accuracy studies. Two channels were excavated to facilitate ionization chamber insertion for dosimetric measurements. Phantom properties such as deformable gel elasticity and HU stability were studied. The dosimetric measurement accuracy in the phantom was performed, and the DIR accuracies of three DIR algorithms available in the open source DIR toolkit-DIRART were also validated.The constructed deformable gel showed elastic behavior and was stable in HU values over times, proving to be a practical material for the deformable phantom. The constructed abdominal phantom consisted of realistic anatomies in terms of both anatomical shapes and densities when compared with its reference patient. The dosimetric measurements showed a good agreement with the calculated doses from the treatment planning system. Fiducial-based accuracy analysis conducted on the constructed phantom demonstrated the feasibility of applying the phantom for organ-wise DIR accuracy assessment.We have designed and constructed an anthropomorphic abdominal deformable phantom with satisfactory elastic property, realistic organ density, and anatomy. This physical phantom can be used for routine validations of DIR geometric accuracy and dose accumulation accuracy in ART.
View details for DOI 10.1002/mp.12229
View details for Web of Science ID 000408033400030
View details for PubMedID 28317122
-
A novel geometry-dosimetry label fusion method in multi-atlas segmentation for radiotherapy: a proof-of-concept study
PHYSICS IN MEDICINE AND BIOLOGY
2017; 62 (9): 3656–67
Abstract
Multi-atlas segmentation (MAS) has been widely used to automate the delineation of organs at risk (OARs) for radiotherapy. Label fusion is a crucial step in MAS to cope with the segmentation variabilities among multiple atlases. However, most existing label fusion methods do not consider the potential dosimetric impact of the segmentation result. In this proof-of-concept study, we propose a novel geometry-dosimetry label fusion method for MAS-based OAR auto-contouring, which evaluates the segmentation performance in terms of both geometric accuracy and the dosimetric impact of the segmentation accuracy on the resulting treatment plan. Differently from the original selective and iterative method for performance level estimation (SIMPLE), we evaluated and rejected the atlases based on both Dice similarity coefficient and the predicted error of the dosimetric endpoints. The dosimetric error was predicted using our previously developed geometry-dosimetry model. We tested our method in MAS-based rectum auto-contouring on 20 prostate cancer patients. The accuracy in the rectum sub-volume close to the planning tumor volume (PTV), which was found to be a dosimetric sensitive region of the rectum, was greatly improved. The mean absolute distance between the obtained contour and the physician-drawn contour in the rectum sub-volume 2 mm away from PTV was reduced from 3.96 mm to 3.36 mm on average for the 20 patients, with the maximum decrease found to be from 9.22 mm to 3.75 mm. We also compared the dosimetric endpoints predicted for the obtained contours with those predicted for the physician-drawn contours. Our method led to smaller dosimetric endpoint errors than the SIMPLE method in 15 patients, comparable errors in 2 patients, and slightly larger errors in 3 patients. These results indicated the efficacy of our method in terms of considering both geometric accuracy and dosimetric impact during label fusion. Our algorithm can be applied to different tumor sites and radiation treatments, given a specifically trained geometry-dosimetry model.
View details for DOI 10.1088/1361-6560/aa5ed9
View details for Web of Science ID 000399212500016
View details for PubMedID 28379850
-
Comprehensive evaluation of ten deformable image registration algorithms for contour propagation between CT and cone-beam CT images in adaptive head & neck radiotherapy
PLOS ONE
2017; 12 (4): e0175906
Abstract
Deformable image registration (DIR) is a critical technic in adaptive radiotherapy (ART) for propagating contours between planning computerized tomography (CT) images and treatment CT/cone-beam CT (CBCT) images to account for organ deformation for treatment re-planning. To validate the ability and accuracy of DIR algorithms in organ at risk (OAR) contour mapping, ten intensity-based DIR strategies, which were classified into four categories-optical flow-based, demons-based, level-set-based and spline-based-were tested on planning CT and fractional CBCT images acquired from twenty-one head & neck (H&N) cancer patients who underwent 6~7-week intensity-modulated radiation therapy (IMRT). Three similarity metrics, i.e., the Dice similarity coefficient (DSC), the percentage error (PE) and the Hausdorff distance (HD), were employed to measure the agreement between the propagated contours and the physician-delineated ground truths of four OARs, including the vertebra (VTB), the vertebral foramen (VF), the parotid gland (PG) and the submandibular gland (SMG). It was found that the evaluated DIRs in this work did not necessarily outperform rigid registration. DIR performed better for bony structures than soft-tissue organs, and the DIR performance tended to vary for different ROIs with different degrees of deformation as the treatment proceeded. Generally, the optical flow-based DIR performed best, while the demons-based DIR usually ranked last except for a modified demons-based DISC used for CT-CBCT DIR. These experimental results suggest that the choice of a specific DIR algorithm depends on the image modality, anatomic site, magnitude of deformation and application. Therefore, careful examinations and modifications are required before accepting the auto-propagated contours, especially for automatic re-planning ART systems.
View details for DOI 10.1371/journal.pone.0175906
View details for Web of Science ID 000399874800076
View details for PubMedID 28414799
View details for PubMedCentralID PMC5393623
-
Automatic metastatic brain tumor segmentation for stereotactic radiosurgery applications
PHYSICS IN MEDICINE AND BIOLOGY
2016; 61 (24): 8440–61
Abstract
The objective of this study is to develop an automatic segmentation strategy for efficient and accurate metastatic brain tumor delineation on contrast-enhanced T1-weighted (T1c) magnetic resonance images (MRI) for stereotactic radiosurgery (SRS) applications. The proposed four-step automatic brain metastases segmentation strategy is comprised of pre-processing, initial contouring, contour evolution, and contour triage. First, T1c brain images are preprocessed to remove the skull. Second, an initial tumor contour is created using a multi-scaled adaptive threshold-based bounding box and a super-voxel clustering technique. Third, the initial contours are evolved to the tumor boundary using a regional active contour technique. Fourth, all detected false-positive contours are removed with geometric characterization. The segmentation process was validated on a realistic virtual phantom containing Gaussian or Rician noise. For each type of noise distribution, five different noise levels were tested. Twenty-one cases from the multimodal brain tumor image segmentation (BRATS) challenge dataset and fifteen clinical metastases cases were also included in validation. Segmentation performance was quantified by the Dice coefficient (DC), normalized mutual information (NMI), structural similarity (SSIM), Hausdorff distance (HD), mean value of surface-to-surface distance (MSSD) and standard deviation of surface-to-surface distance (SDSSD). In the numerical phantom study, the evaluation yielded a DC of 0.98 ± 0.01, an NMI of 0.97 ± 0.01, an SSIM of 0.999 ± 0.001, an HD of 2.2 ± 0.8 mm, an MSSD of 0.1 ± 0.1 mm, and an SDSSD of 0.3 ± 0.1 mm. The validation on the BRATS data resulted in a DC of 0.89 ± 0.08, which outperform the BRATS challenge algorithms. Evaluation on clinical datasets gave a DC of 0.86 ± 0.09, an NMI of 0.80 ± 0.11, an SSIM of 0.999 ± 0.001, an HD of 8.8 ± 12.6 mm, an MSSD of 1.5 ± 3.2 mm, and an SDSSD of 1.8 ± 3.4 mm when comparing to the physician drawn ground truth. The result indicated that the developed automatic segmentation strategy yielded accurate brain tumor delineation and presented as a useful clinical tool for SRS applications.
View details for DOI 10.1088/0031-9155/61/24/8440
View details for Web of Science ID 000388688800003
View details for PubMedID 27845915
-
Cardiac dosimetric evaluation of deep inspiration breath-hold level variances using computed tomography scans generated from deformable image registration displacement vectors
MEDICAL DOSIMETRY
2016; 41 (1): 22–27
Abstract
There is a reduction in cardiac dose for left-sided breast radiotherapy during treatment with deep inspiration breath-hold (DIBH) when compared with treatment with free breathing (FB). Various levels of DIBH may occur for different treatment fractions. Dosimetric effects due to this and other motions are a major component of uncertainty in radiotherapy in this setting. Recent developments in deformable registration techniques allow displacement vectors between various temporal and spatial patient representations to be digitally quantified. We propose a method to evaluate the dosimetric effect to the heart from variable reproducibility of DIBH by using deformable registration to create new anatomical computed tomography (CT) scans. From deformable registration, 3-dimensional deformation vectors are generated with FB and DIBH. The obtained deformation vectors are scaled to 75%, 90%, and 110% and are applied to the reference image to create new CT scans at these inspirational levels. The scans are then imported into the treatment planning system and dose calculations are performed. The average mean dose to the heart was 2.5Gy (0.7 to 9.6Gy) at FB, 1.2Gy (0.6 to 3.8Gy, p < 0.001) at 75% inspiration, 1.1Gy (0.6 to 3.1Gy, p = 0.004) at 90% inspiration, 1.0Gy (0.6 to 3.0Gy) at 100% inspiration or DIBH, and 1.0Gy (0.6 to 2.8Gy, p = 0.019) at 110% inspiration. The average mean dose to the left anterior descending artery (LAD) was 19.9Gy (2.4 to 46.4Gy), 8.6Gy (2.0 to 43.8Gy, p < 0.001), 7.2Gy (1.9 to 40.1Gy, p = 0.035), 6.5Gy (1.8 to 34.7Gy), and 5.3Gy (1.5 to 31.5Gy, p < 0.001), correspondingly. This novel method enables numerous anatomical situations to be mimicked and quantifies the dosimetric effect they have on a treatment plan.
View details for DOI 10.1016/j.meddos.2015.06.004
View details for Web of Science ID 000370206800005
View details for PubMedID 26206154
-
4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling
PHYSICS IN MEDICINE AND BIOLOGY
2016; 61 (3): 996–1020
Abstract
A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.
View details for DOI 10.1088/0031-9155/61/3/996
View details for Web of Science ID 000369517000007
View details for PubMedID 26758496
View details for PubMedCentralID PMC5026392
-
SCORE System for Online Adaptive Radiotherapy
GRAPHICS PROCESSING UNIT-BASED HIGH PERFORMANCE COMPUTING IN RADIATION THERAPY
2016: 351–65
View details for Web of Science ID 000442513400022
-
Patient-specific dosimetric endpoints based treatment plan quality control in radiotherapy
PHYSICS IN MEDICINE AND BIOLOGY
2015; 60 (21): 8213–27
Abstract
In intensity modulated radiotherapy (IMRT), the optimal plan for each patient is specific due to unique patient anatomy. To achieve such a plan, patient-specific dosimetric goals reflecting each patient's unique anatomy should be defined and adopted in the treatment planning procedure for plan quality control. This study is to develop such a personalized treatment plan quality control tool by predicting patient-specific dosimetric endpoints (DEs). The incorporation of patient specific DEs is realized by a multi-OAR geometry-dosimetry model, capable of predicting optimal DEs based on the individual patient's geometry. The overall quality of a treatment plan is then judged with a numerical treatment plan quality indicator and characterized as optimal or suboptimal. Taking advantage of clinically available prostate volumetric modulated arc therapy (VMAT) treatment plans, we built and evaluated our proposed plan quality control tool. Using our developed tool, six of twenty evaluated plans were identified as sub-optimal plans. After plan re-optimization, these suboptimal plans achieved better OAR dose sparing without sacrificing the PTV coverage, and the dosimetric endpoints of the re-optimized plans agreed well with the model predicted values, which validate the predictability of the proposed tool. In conclusion, the developed tool is able to accurately predict optimally achievable DEs of multiple OARs, identify suboptimal plans, and guide plan optimization. It is a useful tool for achieving patient-specific treatment plan quality control.
View details for DOI 10.1088/0031-9155/60/21/8213
View details for Web of Science ID 000366108500004
View details for PubMedID 26447829
-
A Pilot Evaluation of a 4-Dimensional Cone-Beam Computed Tomographic Scheme Based on Simultaneous Motion Estimation and Image Reconstruction
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS
2015; 91 (2): 410–18
Abstract
To evaluate the performance of a 4-dimensional (4-D) cone-beam computed tomographic (CBCT) reconstruction scheme based on simultaneous motion estimation and image reconstruction (SMEIR) through patient studies.The SMEIR algorithm contains 2 alternating steps: (1) motion-compensated CBCT reconstruction using projections from all phases to reconstruct a reference phase 4D-CBCT by explicitly considering the motion models between each different phase and (2) estimation of motion models directly from projections by matching the measured projections to the forward projection of the deformed reference phase 4D-CBCT. Four lung cancer patients were scanned for 4 to 6 minutes to obtain approximately 2000 projections for each patient. To evaluate the performance of the SMEIR algorithm on a conventional 1-minute CBCT scan, the number of projections at each phase was reduced by a factor of 5, 8, or 10 for each patient. Then, 4D-CBCTs were reconstructed from the down-sampled projections using Feldkamp-Davis-Kress, total variation (TV) minimization, prior image constrained compressive sensing (PICCS), and SMEIR. Using the 4D-CBCT reconstructed from the fully sampled projections as a reference, the relative error (RE) of reconstructed images, root mean square error (RMSE), and maximum error (MaxE) of estimated tumor positions were analyzed to quantify the performance of the SMEIR algorithm.The SMEIR algorithm can achieve results consistent with the reference 4D-CBCT reconstructed with many more projections per phase. With an average of 30 to 40 projections per phase, the MaxE in tumor position detection is less than 1 mm in SMEIR for all 4 patients.The results from a limited number of patients show that SMEIR is a promising tool for high-quality 4D-CBCT reconstruction and tumor motion modeling.
View details for DOI 10.1016/j.ijrobp.2014.10.029
View details for Web of Science ID 000348045400023
View details for PubMedID 25636763
-
Automated landmark-guided deformable image registration
PHYSICS IN MEDICINE AND BIOLOGY
2015; 60 (1): 101–16
Abstract
The purpose of this work is to develop an automated landmark-guided deformable image registration (LDIR) algorithm between the planning CT and daily cone-beam CT (CBCT) with low image quality. This method uses an automated landmark generation algorithm in conjunction with a local small volume gradient matching search engine to map corresponding landmarks between the CBCT and the planning CT. The landmarks act as stabilizing control points in the following Demons deformable image registration. LDIR is implemented on graphics processing units (GPUs) for parallel computation to achieve ultra fast calculation. The accuracy of the LDIR algorithm has been evaluated on a synthetic case in the presence of different noise levels and data of six head and neck cancer patients. The results indicate that LDIR performed better than rigid registration, Demons, and intensity corrected Demons for all similarity metrics used. In conclusion, LDIR achieves high accuracy in the presence of multimodality intensity mismatch and CBCT noise contamination, while simultaneously preserving high computational efficiency.
View details for DOI 10.1088/0031-9155/60/1/101
View details for Web of Science ID 000346479700009
View details for PubMedID 25479095
-
Breaking bad IMRT QA practice
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS
2015; 16 (3): 154–65
Abstract
Agreement between planned and delivered dose distributions for patient-specific quality assurance in routine clinical practice is predominantly assessed utilizing the gamma index method. Several reports, however, fundamentally question current IMRT QA practice due to poor sensitivity and specificity of the standard gamma index implementation. An alternative is to employ dose volume histogram (DVH)-based metrics. An analysis based on the AAPM TG 53 and ESTRO booklet No.7 recommendations for QA of treatment planning systems reveals deficiencies in the current "state of the art" IMRT QA, no matter which metric is selected. The set of IMRT benchmark plans were planned, delivered, and analyzed by following guidance of the AAPM TG 119 report. The recommended point dose and planar dose measurements were obtained using a PinPoint ionization chamber, EDR2 radiographic film, and a 2D ionization chamber array. Gamma index criteria {3% (global), 3 mm} and {3% (local), 3 mm} were used to assess the agreement between calculated and delivered planar dose distributions. Next, the AAPM TG 53 and ESTRO booklet No.7 recommendations were followed by dividing dose distributions into four distinct regions: the high-dose (HD) or umbra region, the high-gradient (HG) or penumbra region, the medium-dose (MD) region, and the low-dose (LD) region. A different gamma passing criteria was defined for each region, i.e., a "divide and conquer" (D&C) gamma method was utilized. The D&C gamma analysis was subsequently tested on 50 datasets of previously treated patients. Measured point dose and planar dose distributions compared favorably with TG 119 benchmark data. For all complex tests, the percentage of points passing the conventional {3% (global), 3 mm} gamma criteria was 97.2% ± 3.2% and 95.7% ± 1.2% for film and 2D ionization chamber array, respectively. By dividing 2D ionization chamber array dose measurements into regions and applying 3mm isodose point distance and variable local point dose difference criteria of 7%, 15%, 25%, and 40% for HD, HG, MD, and LD regions, respectively, a 93.4% ± 2.3% gamma passing rate was obtained. Identical criteria applied using the D&C gamma technique on 50 clinical treatment plans resulted in a 97.9% ± 2.3% gamma passing score. Based on the TG 119 standard, meeting or exceeding the benchmark results would indicate an exemplary IMRT QA program. In contrast to TG 119 analysis, a different scrutiny on the same set of data, which follows the AAPM TG 53 and ESTRO booklet No.7 guidelines, reveals a much poorer agreement between calculated and measured dose distributions with large local point dose differences within different dose regions. This observation may challenge the conventional wisdom that an IMRT QA program is producing acceptable results.
View details for DOI 10.1120/jacmp.v16i3.5242
View details for Web of Science ID 000354950100015
View details for PubMedID 26103484
View details for PubMedCentralID PMC5690124
-
Deformation vector fields (DVF)-driven image reconstruction for 4D-CBCT
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY
2015; 23 (1): 11–23
Abstract
High quality 4D-CBCT can be obtained by deforming a planning CT (pCT), where the deformation vector fields (DVF) are estimated by matching the forward projections of pCT and 4D-CBCT projections. The matching metric used in the previous study is the sum of squared intensity differences (SSID). The scatter signal level in CBCT projections is much higher than pCT, the SSID metric may not lead to optimal DVF.To improve the DVF estimation accuracy, we develop a new matching metric that is less sensitive to the intensity level difference caused by the scatter signal.The negative logarithm of correlation coefficient (NLCC) is used as the matching metric. A non-linear conjugate gradient optimization algorithm is used to estimate the DVF. A 4D NCAT phantom and an anthropomorphic thoracic phantom were used to evaluate the NLCC-based algorithm.In the NCAT phantom study, the relative reconstruction error is reduced from 18.0% in SSID to 14.13% in NLCC. In the thoracic phantom study, the root mean square error of the tumor motion is reduced from 1.16 mm in SSID to 0.43 mm in NLCC.NLCC metric can improve the image reconstruction and motion estimation accuracy of DVF-driven image reconstruction for 4D-CBCT.
View details for DOI 10.3233/XST-140466
View details for Web of Science ID 000347450700002
View details for PubMedID 25567403
-
Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
MEDICAL PHYSICS
2013; 40 (10): 101912
Abstract
Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.
View details for DOI 10.1118/1.4821099
View details for Web of Science ID 000325394400028
View details for PubMedID 24089914
-
High-quality four-dimensional cone-beam CT by deforming prior images
PHYSICS IN MEDICINE AND BIOLOGY
2013; 58 (2): 231–46
Abstract
Due to a limited number of projections at each phase, severe view aliasing artifacts are present in four-dimensional cone beam computed tomography (4D-CBCT) when reconstruction is performed using conventional algorithms. In this work, we aim to obtain high-quality 4D-CBCT of lung cancer patients in radiation therapy by deforming the planning CT. The deformation vector fields (DVF) to deform the planning CT are estimated through matching the forward projection of the deformed prior image and measured on-treatment CBCT projection. The estimation of the DVF is formulated as an unconstrained optimization problem, where the objective function to be minimized is the sum of the squared difference between the forward projection of the deformed planning CT and the measured 4D-CBCT projection. A nonlinear conjugate gradient method is used to solve the DVF. As the number of the variables in the DVF is much greater than the number of measurements, the solution to such a highly ill-posed problem is very sensitive to the initials during the optimization process. To improve the estimation accuracy of DVF, we proposed a new strategy to obtain better initials for the optimization. In this strategy, 4D-CBCT is first reconstructed by total variation minimization. Demons deformable registration is performed to register the planning CT and the 4D-CBCT reconstructed by total variation minimization. The resulted DVF from demons registration is then used as the initial parameters in the optimization process. A 4D nonuniform rotational B-spline-based cardiac-torso (NCAT) phantom and a patient 4D-CBCT are used to evaluate the algorithm. Image quality of 4D-CBCT is substantially improved by using the proposed strategy in both NCAT phantom and patient studies. The proposed method has the potential to improve the temporal resolution of 4D-CBCT. Improved 4D-CBCT can better characterize the motion of lung tumors and will be a valuable tool for image-guided adaptive radiation therapy.
View details for DOI 10.1088/0031-9155/58/2/231
View details for Web of Science ID 000312674400005
View details for PubMedID 23257113