Lingyun Xu
Life Science Research Professional 2, Cardiovascular Institute Operations
All Publications
-
Alternative medicine: therapeutic effects on gastric original signet ring carcinoma via ascorbate and combination with sodium alpha lipoate.
BMC complementary medicine and therapies
2022; 22 (1): 58
Abstract
BACKGROUND: Gastric signet ring cell carcinoma (SRCC) is an aggressive gastric adenocarcinoma with a poor prognosis when diagnosed at an advanced stage. As alternative medicine, two natural supplements (ascorbate (AA) and sodium alpha lipoate (LA)) have been shown to inhibit various cancers with mild side effects.METHODS: These two natural supplements and a series of combinations (AA&LA, AA+LA and LA+AA) were incubated with non-SRCC cells (GPM-1), patient-derived gastric origin SRCC (GPM-2), gastric-origin SRCCs (HSC-39 and KATO-3), human pancreatic (MIA PaCa-2) and ovarian (SKOV-3) cells for evaluating their therapeutic effects. Moreover, these treatments were applied in 3D-cultured organoids to reveal the feasibility of these approaches for in vivo study.RESULTS: Analyzing their antioxidant capabilities and dose-response curves, we observed that all four gastric cell lines, including three patient-derived cell lines were sensitive to ascorbate (~10mM). The influence of ascorbate incubation time was studied, with a 16-h incubation found to be optimal for in vitro studies. Moreover, a simultaneous combination of AA and LA (AA&LA) did not significantly inhibit cell proliferation, while prior LA treatment increased the growth inhibition of AA therapy (LA+AA). Anti-cancer efficacy of AA was further confirmed in 3D-cultured SRCC (KATO-3) organoids.CONCLUSIONS: This study highlights the potential of AA and LA+AA in treating gastric origin SRCC, and demonstrates the influence of order in which the drugs are administered.
View details for DOI 10.1186/s12906-022-03541-0
View details for PubMedID 35255889
-
Gold Nanoclusters for NIR-II Fluorescence Imaging of Bones.
Small (Weinheim an der Bergstrasse, Germany)
2020: e2003851
Abstract
Fluorescence imaging in the second near-infrared window (NIR-II, 1000-1700 nm) holds great promise for deep tissue visualization. Development of novel clinical translatable NIR-II probes is crucial for realizing the medical applications of NIR-II fluorescence imaging. Herein, the glutathione-capped gold nanoclusters (AuNCs, specifically Au25 (SG)18 ) demonstrate highly efficient binding capability to hydroxyapatite in vitro for the first time. Further in vivo NIR-II fluorescence imaging of AuNCs indicate that they accumulate in bone tissues with high contrast and signal-background ratio. AuNCs are also mainly and quickly excreted from body through renal system, showing excellent ribs and thoracic vertebra imaging because of no background signal in liver and spleen. The deep tissue penetration capability and high resolution of AuNCs in NIR-II imaging render their great potential for fluorescence-guided surgery like spinal pedicle screw implantation. Overall, AuNCs are highly promising and clinical translatable NIR-II imaging probe for visualizing bone and bone related abnormalities.
View details for DOI 10.1002/smll.202003851
View details for PubMedID 33000882
-
Improved detection of prostate cancer using a magneto-nanosensor assay for serum circulating autoantibodies.
PloS one
2019; 14 (8): e0221051
Abstract
PURPOSE: To develop a magneto-nanosensor (MNS) based multiplex assay to measure protein and autoantibody biomarkers from human serum for prostate cancer (CaP) diagnosis.MATERIALS AND METHODS: A 4-panel MNS autoantibody assay and a MNS protein assay were developed and optimized in our labs. Using these assays, serum concentration of six biomarkers including prostate-specific antigen (PSA) protein, free/total PSA ratio, as well as four autoantibodies against Parkinson disease 7 (PARK7), TAR DNA-binding protein 43 (TARDBP), Talin 1 (TLN1), and Caldesmon 1 (CALD1) and were analyzed. Human serum samples from 99 patients (50 with non-cancer and 49 with clinically localized CaP) were evaluated.RESULTS: The MNS assay showed excellent performance characteristics and no cross-reactivity. All autoantibody assays showed a statistically significant difference between CaP and non-cancer samples except for PARK7. The most significant difference was the combination of the four autoantibodies as a panel in addition to the free/total PSA ratio. This combination had the highest area under the curve (AUC)- 0.916 in ROC analysis.CONCLUSIONS: Our results suggest that this autoantibody panel along with PSA and free PSA have potential to segregate patients without cancer from those with prostate cancer with higher sensitivity and specificity than PSA alone.
View details for DOI 10.1371/journal.pone.0221051
View details for PubMedID 31404106
-
A blood biomarker for monitoring response to anti-EGFR therapy.
Cancer biomarkers : section A of Disease markers
2018
Abstract
BACKGROUND AND OBJECTIVE: To monitor therapies targeted to epidermal growth factor receptors (EGFR) in non-small cell lung cancer (NSCLC), we investigated Peroxiredoxin 6 (PRDX6) as a biomarker of response to anti-EGFR agents.METHODS: We studied cells that are sensitive (H3255, HCC827) or resistant (H1975, H460) to gefitinib. PRDX6 was examined with either gefitinib or vehicle treatment using enzyme-linked immunosorbent assays. We created xenograft models from one sensitive (HCC827) and one resistant cell line (H1975) and monitored serum PRDX6 levels during treatment.RESULTS: PRDX6 levels in cell media from sensitive cell lines increased significantly after gefitinib treatment vs. vehicle, whereas there was no significant difference for resistant lines. PRDX6 accumulation over time correlated positively with gefitinib sensitivity. Serum PRDX6 levels in gefitinib-sensitive xenograft models increased markedly during the first 24 hours of treatment and then decreased dramatically during the following 48 hours. Differences in serum PRDX6 levels between vehicle and gefitinib-treated animals could not be explained by differences in tumor burden.CONCLUSIONS: Our results show that changes in serum PRDX6 during the course of gefitinib treatment of xenograft models provide insight into tumor response and such an approach offers several advantages over imaging-based strategies for monitoring response to anti-EGFR agents.
View details for PubMedID 29689709
-
A Cystine Knot Peptide Targeting Integrin alpha(v)beta(6) for Photoacoustic and Fluorescence Imaging of Tumors in Living Subjects
JOURNAL OF NUCLEAR MEDICINE
2016; 57 (10): 1629-1634
Abstract
Photoacoustic imaging is a nonionizing biomedical imaging modality with higher resolution and imaging depth than fluorescence imaging, which has greater sensitivity. The combination of the 2 imaging modalities could improve the detection of cancer. Integrin αvβ6 is a cell surface marker overexpressed in many different cancers. Here, we report the development and evaluation of a dye-labeled cystine knot peptide, which selectively recognizes integrin αvβ6 with high affinity, for photoacoustic and fluorescence imaging. The new dual-modality probe may find clinical application in cancer diagnosis and intraoperative imaging of integrin αvβ6-positive tumors.An engineered cystine knot peptide, R01, that recognizes integrin αvβ6 was labeled with Atto 740 (A740) and evaluated for its specific cell uptake and its sensitivity threshold. A740-R01 was injected via the tail vein into nude mice xenografted with A431 (integrin αvβ6-positive) or 293T (integrin αvβ6-negative) tumors. Photoacoustic and fluorescence scans of tumors were acquired before and at 0.5, 1, 2, and 4 h after injection of A740-R01. Dynamic photoacoustic scans of various normal organs were also acquired. Ex vivo fluorescence imaging of tissues was performed 1 h after injection.The A740-R01 demonstrated integrin αvβ6-dependent binding to A431 cells in culture. Sensitivity studies indicated that the probe may potentially detect lesions as small as 1 or 6 mm(3) by fluorescence or photoacoustic imaging, respectively. The photoacoustic and fluorescence signals of A431 xenografts at 1 h after injection were 1.87 ± 0.25 arbitrary units (AU) and 8.27 ± 0.87 AU, respectively. Target specificity was confirmed by low tumor uptake in 293T tumors at 1 h after injection (1.07 ± 0.15 AU and 1.10 ± 0.14 AU for photoacoustic and fluorescence signals, respectively). A740-R01 exhibited hepatobiliary clearance marked by high uptake in the liver, spleen, and intestine but low uptake in the kidneys.A740-R01 specifically targeted integrin αvβ6 with low nanomolar affinity. A740-R01 was able to detect integrin αvβ6 both in vitro and in vivo by photoacoustic and fluorescence imaging. A740-R01 is able to detect αvβ6-positive tumors in living subjects and may have clinical application in cancer diagnosis and real-time image-guided surgery.
View details for DOI 10.2967/jnumed.115.169383
View details for Web of Science ID 000384961900031
View details for PubMedID 27230926
-
AshwaMAX and Withaferin A inhibits gliomas in cellular and murine orthotopic models.
Journal of neuro-oncology
2016; 126 (2): 253-64
Abstract
Glioblastoma multiforme (GBM) is an aggressive, malignant cancer Johnson and O'Neill (J Neurooncol 107: 359-364, 2012). An extract from the winter cherry plant (Withania somnifera ), AshwaMAX, is concentrated (4.3 %) for Withaferin A; a steroidal lactone that inhibits cancer cells Vanden Berghe et al. (Cancer Epidemiol Biomark Prev 23: 1985-1996, 2014). We hypothesized that AshwaMAX could treat GBM and that bioluminescence imaging (BLI) could track oral therapy in orthotopic murine models of glioblastoma. Human parietal-cortical glioblastoma cells (GBM2, GBM39) were isolated from primary tumors while U87-MG was obtained commercially. GBM2 was transduced with lentiviral vectors that express Green Fluorescent Protein (GFP)/firefly luciferase fusion proteins. Mutational, expression and proliferative status of GBMs were studied. Intracranial xenografts of glioblastomas were grown in the right frontal regions of female, nude mice (n = 3-5 per experiment). Tumor growth was followed through BLI. Neurosphere cultures (U87-MG, GBM2 and GBM39) were inhibited by AshwaMAX at IC50 of 1.4, 0.19 and 0.22 µM equivalent respectively and by Withaferin A with IC50 of 0.31, 0.28 and 0.25 µM respectively. Oral gavage, every other day, of AshwaMAX (40 mg/kg per day) significantly reduced bioluminescence signal (n = 3 mice, p < 0.02, four parameter non-linear regression analysis) in preclinical models. After 30 days of treatment, bioluminescent signal increased suggesting onset of resistance. BLI signal for control, vehicle-treated mice increased and then plateaued. Bioluminescent imaging revealed diffuse growth of GBM2 xenografts. With AshwaMAX, GBM neurospheres collapsed at nanomolar concentrations. Oral treatment studies on murine models confirmed that AshwaMAX is effective against orthotopic GBM. AshwaMAX is thus a promising candidate for future clinical translation in patients with GBM.
View details for DOI 10.1007/s11060-015-1972-1
View details for PubMedID 26650066
-
AshwaMAX and Withaferin A inhibits gliomas in cellular and murine orthotopic models
JOURNAL OF NEURO-ONCOLOGY
2016; 126 (2): 253-264
Abstract
Glioblastoma multiforme (GBM) is an aggressive, malignant cancer Johnson and O'Neill (J Neurooncol 107: 359-364, 2012). An extract from the winter cherry plant (Withania somnifera ), AshwaMAX, is concentrated (4.3 %) for Withaferin A; a steroidal lactone that inhibits cancer cells Vanden Berghe et al. (Cancer Epidemiol Biomark Prev 23: 1985-1996, 2014). We hypothesized that AshwaMAX could treat GBM and that bioluminescence imaging (BLI) could track oral therapy in orthotopic murine models of glioblastoma. Human parietal-cortical glioblastoma cells (GBM2, GBM39) were isolated from primary tumors while U87-MG was obtained commercially. GBM2 was transduced with lentiviral vectors that express Green Fluorescent Protein (GFP)/firefly luciferase fusion proteins. Mutational, expression and proliferative status of GBMs were studied. Intracranial xenografts of glioblastomas were grown in the right frontal regions of female, nude mice (n = 3-5 per experiment). Tumor growth was followed through BLI. Neurosphere cultures (U87-MG, GBM2 and GBM39) were inhibited by AshwaMAX at IC50 of 1.4, 0.19 and 0.22 µM equivalent respectively and by Withaferin A with IC50 of 0.31, 0.28 and 0.25 µM respectively. Oral gavage, every other day, of AshwaMAX (40 mg/kg per day) significantly reduced bioluminescence signal (n = 3 mice, p < 0.02, four parameter non-linear regression analysis) in preclinical models. After 30 days of treatment, bioluminescent signal increased suggesting onset of resistance. BLI signal for control, vehicle-treated mice increased and then plateaued. Bioluminescent imaging revealed diffuse growth of GBM2 xenografts. With AshwaMAX, GBM neurospheres collapsed at nanomolar concentrations. Oral treatment studies on murine models confirmed that AshwaMAX is effective against orthotopic GBM. AshwaMAX is thus a promising candidate for future clinical translation in patients with GBM.
View details for DOI 10.1007/s11060-015-1972-1
View details for Web of Science ID 000368728300005
-
Novel Radiotracer for ImmunoPET Imaging of PD-1 Checkpoint Expression on Tumor Infiltrating Lymphocytes.
Bioconjugate chemistry
2015; 26 (10): 2062-2069
Abstract
Immune checkpoint signaling through the programmed death 1 (PD-1) axis to its ligand (PD-L1) significantly dampens anti-tumor immune responses. Cancer patients treated with checkpoint inhibitors that block this suppressive signaling have exhibited objective response rates of 20-40% for advanced solid tumors, lymphomas, and malignant melanomas. This represents a tremendous advance in cancer treatment. Unfortunately, all patients do not respond to immune checkpoint blockade. Recent findings suggest that patients with tumor infiltrating lymphocytes (TILs) expressing PD-1 may be most likely to respond to αPD-1/PD-L1 checkpoint inhibitors. There is a compelling need for diagnostic and prognostic imaging tools to assess the PD-1 status of TILs in vivo. Here we have developed a novel immunoPET tracer to image PD-1 expressing TILs in a transgenic mouse model bearing melanoma. A (64)Cu labeled anti-mouse antibody (IgG) PD-1 immuno positron emission tomography (PET) tracer was developed to detect PD-1 expressing murine TILs. Quality control of the tracer showed >95% purity by HPLC and >70% immunoreactivity in an in vitro cell binding assay. ImmunoPET scans were performed over 1-48 h on Foxp3+.LuciDTR4 mice bearing B16-F10 melanoma tumors. Mice receiving anti-PD-1 tracer (200 ± 10 μCi/10-12 μg/200 μL) revealed high tracer uptake in lymphoid organs and tumors. BLI images of FoxP3(+) CD4(+) Tregs known to express PD-1 confirmed lymphocyte infiltration of tumors at the time of PET imaging. Biodistribution measurements performed at 48 h revealed a high (11×) tumor to muscle uptake ratio of the PET tracer (p < 0.05). PD-1 tumors exhibited 7.4 ± 0.7%ID/g tracer uptake and showed a 2× fold signal decrease when binding was blocked by unlabeled antibody. To the best of our knowledge this data is the first report to image PD-1 expression in living subjects with PET. This radiotracer has the potential to assess the prognostic value of PD-1 in preclinical models of immunotherapy and may ultimately aid in predicting response to therapies targeting immune checkpoints.
View details for DOI 10.1021/acs.bioconjchem.5b00318
View details for PubMedID 26307602
-
A Magnetic Bead-Based Sensor for the Quantification of Multiple Prostate Cancer Biomarkers.
PloS one
2015; 10 (9)
Abstract
Novel biomarker assays and upgraded analytical tools are urgently needed to accurately discriminate benign prostatic hypertrophy (BPH) from prostate cancer (CaP). To address this unmet clinical need, we report a piezeoelectric/magnetic bead-based assay to quantitate prostate specific antigen (PSA; free and total), prostatic acid phosphatase, carbonic anhydrase 1 (CA1), osteonectin, IL-6 soluble receptor (IL-6sr), and spondin-2. We used the sensor to measure these seven proteins in serum samples from 120 benign prostate hypertrophy patients and 100 Gleason score 6 and 7 CaP using serum samples previously collected and banked. The results were analyzed with receiver operator characteristic curve analysis. There were significant differences between BPH and CaP patients in the PSA, CA1, and spondin-2 assays. The highest AUC discrimination was achieved with a spondin-2 OR free/total PSA operation-the area under the curve was 0.84 with a p value below 10-6. Some of these data seem to contradict previous reports and highlight the importance of sample selection and proper assay building in the development of biomarker measurement schemes. This bead-based system offers important advantages in assay building including low cost, high throughput, and rapid identification of an optimal matched antibody pair.
View details for DOI 10.1371/journal.pone.0139484
View details for PubMedID 26421725
View details for PubMedCentralID PMC4589536
-
A Magnetic Bead-Based Sensor for the Quantification of Multiple Prostate Cancer Biomarkers.
PloS one
2015; 10 (9): e0139484
Abstract
Novel biomarker assays and upgraded analytical tools are urgently needed to accurately discriminate benign prostatic hypertrophy (BPH) from prostate cancer (CaP). To address this unmet clinical need, we report a piezeoelectric/magnetic bead-based assay to quantitate prostate specific antigen (PSA; free and total), prostatic acid phosphatase, carbonic anhydrase 1 (CA1), osteonectin, IL-6 soluble receptor (IL-6sr), and spondin-2. We used the sensor to measure these seven proteins in serum samples from 120 benign prostate hypertrophy patients and 100 Gleason score 6 and 7 CaP using serum samples previously collected and banked. The results were analyzed with receiver operator characteristic curve analysis. There were significant differences between BPH and CaP patients in the PSA, CA1, and spondin-2 assays. The highest AUC discrimination was achieved with a spondin-2 OR free/total PSA operation-the area under the curve was 0.84 with a p value below 10-6. Some of these data seem to contradict previous reports and highlight the importance of sample selection and proper assay building in the development of biomarker measurement schemes. This bead-based system offers important advantages in assay building including low cost, high throughput, and rapid identification of an optimal matched antibody pair.
View details for DOI 10.1371/journal.pone.0139484
View details for PubMedID 26421725
View details for PubMedCentralID PMC4589536
-
Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips
LAB ON A CHIP
2014; 14 (1): 78-88
View details for DOI 10.1039/c3lc50580d
View details for Web of Science ID 000327669000008
-
Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips.
Lab on a chip
2013; 14 (1): 78-88
Abstract
Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of "liquid biopsies" from cancer patients.
View details for DOI 10.1039/c3lc50580d
View details for PubMedID 23969419