Bio


Piotr Dubrowski is a Canadian trained and board-certified Therapy Medical Physicist. Throughout his career Piotr has had the opportunity to bring several new Cancer Clinics operational from the ground up, where he was able to hone a broad, systems-approach to Radiation Oncology. He was recently promoted to Associate Quality Director of Physics responsible for improving patient safety and workflow/technology improvements across a wide cancer care network. Piotr’s research interests focus mainly on improving the treatment planning process and increasing clinic safety through software development and hardware 3D-print prototyping. Additionally, Piotr has sought out opportunities to give back to the Global community with participation in the Stanford Global Radiation Oncology Outreach efforts expanding education and access to care in Tanzania and Kenya and throughout the developing world via online Radiation Therapy courses.

Academic Appointments


2023-24 Courses


All Publications


  • Shaping success: clinical implementation of a 3D-printed electron cutout program in external beam radiation therapy. Frontiers in oncology Schulz, J. B., Gibson, C., Dubrowski, P., Marquez, C. M., Million, L., Qian, Y., Skinner, L., Yu, A. S. 2023; 13: 1237037

    Abstract

    The integration of 3D-printing technology into radiation therapy (RT) has allowed for a novel method to develop personalized electron field-shaping blocks with improved accuracy. By obviating the need for handling highly toxic Cerrobend molds, the clinical workflow is significantly streamlined. This study aims to expound upon the clinical workflow of 3D-printed electron cutouts in RT and furnish one year of in-vivo dosimetry data.3D-printed electron cutouts for 6x6 cm, 10x10 cm, and 15x15 cm electron applicators were designed and implemented into the clinical workflow after dosimetric commissioning to ensure congruence with the Cerrobend cutouts. The clinical workflow consisted of four parts: i) the cutout aperture was extracted from the treatment planning system (TPS). A 3D printable cutout was then generated automatically through custom scripts; ii) the cutout was 3D-printed with PLA filament, filled with tungsten ball bearings, and underwent quality assurance (QA) to verify density and dosimetry; iii) in-vivo dosimetry was performed with optically stimulated luminescence dosimeters (OSLDs) for a patient's first treatment and compared to the calculated dose in the TPS; iv) after treatment completion, the 3D-printed cutout was recycled.QA and in-vivo OSLD measurements were conducted (n=40). The electron cutouts produced were 6x6 cm (n=3), 10x10 cm (n=30), and 15x15 cm (n=7). The expected weight of the cutouts differed from the measured weight by 0.4 + 1.1%. The skin dose measured with the OSLDs was compared to the skin dose in the TPS on the central axis. The difference between the measured and TPS doses was 4.0 + 5.2%.The successful clinical implementation of 3D-printed cutouts reduced labor, costs, and removed the use of toxic materials in the workplace while meeting clinical dosimetric standards.

    View details for DOI 10.3389/fonc.2023.1237037

    View details for PubMedID 37621682

    View details for PubMedCentralID PMC10445153

  • An affordable platform for virtual reality-based patient education in radiation therapy. Practical radiation oncology Schulz, J. B., Dubrowski, P., Blomain, E., Million, L., Qian, Y., Marquez, C., Yu, A. S. 2023

    Abstract

    The goal of this study is to develop and assess the effectiveness of an affordable smartphone-based Virtual Reality (VR) patient education platform with 360-degree videos produced depicting a first-person patient perspective during the radiation therapy (RT) care path to reduce patient anxiety.and Materials Three disease site-specific (breast, pelvis, head and neck) VR-videos were filmed using a 360-degree camera to portray the first-person perspective of a patient's standard RT appointments: including a Computed Tomography (CT) simulation and the first RT treatment session. Instruction is given for possible clinical implementation. Patient participation was divided into two groups: 1) Group-A (n=28) included patients participating before simulation and later after the first treatment, and 2) Group-B (n=33) included patients participating only while undergoing treatment. Patients viewed their disease site-specific video using an inexpensive cardboard VR-viewer and their smartphone, emulating an expensive VR-headset. Surveys were administered assessing patient anxiety, comfort, satisfaction, and knowledge of RT on a 5-point Likert-type scale.Patients in Group-A and Group-B while undergoing treatment both selected their anxiety "decreased a little" in the survey, after watching the VR-video (Group-A, median on a 5-point Likert-type scale, 4 [interquartile range {IQR}, 4-5]; Group-B, 4 [IQR 4-4]). The VR aspect of the videos was especially liked by patients while undergoing treatment, with 96.4% in Group-A and 90.9% in Group-B reporting that the VR aspect of the videos was helpful. All Group-A participants believed that the VR-videos would be beneficial to new patients.Our affordable VR patient education platform effectively immerses a patient in their care path from simulation through initial treatment delivery, reducing anxiety and increasing familiarity with the treatment process.

    View details for DOI 10.1016/j.prro.2023.06.008

    View details for PubMedID 37482182

  • Learning image representations for content-based image retrieval of radiotherapy treatment plans. Physics in medicine and biology Huang, C., Vasudevan, V., Pastor-Serrano, O., Islam, M. T., Nomura, Y., Dubrowski, P., Wang, J. Y., Schulz, J. B., Yang, Y., Xing, L. 2023

    Abstract

    In this work, we propose a content-based image retrieval (CBIR) method for retrieving dose distributions of previously planned patients based on anatomical similarity. Retrieved dose distributions from this method can be incorporated into automated treatment planning workflows in order to streamline the iterative planning process. As CBIR has not yet been applied to treatment planning, our work seeks to understand which current machine learning models are most viable in this context.Our proposed CBIR method trains a representation model that produces latent space embeddings of a patient's anatomical information. The latent space embeddings of new patients are then compared against those of previous patients in a database for image retrieval of dose distributions. All source code for this project is available on github.The retrieval performance of various CBIR methods is evaluated on a dataset consisting of both publicly available image sets and clinical image sets from our institution. This study compares various encoding methods, ranging from simple autoencoders to more recent Siamese networks like SimSiam, and the best performance was observed for the multitask Siamese network.Our current results demonstrate that excellent image retrieval performance can be obtained through slight changes to previously developed Siamese networks. We hope to integrate CBIR into automated planning workflow in future works.

    View details for DOI 10.1088/1361-6560/accdb0

    View details for PubMedID 37068492

  • Pancreatic Stereotactic Body Radiation Therapy with or without Hypofractionated Elective Nodal Irradiation. International journal of radiation oncology, biology, physics Miller, J. A., Toesca, D. A., Baclay, J. R., Vitzthum, L. K., Dubrowski, P., Pollom, E. L., Chang, D. T. 2021

    Abstract

    PURPOSE/OBJECTIVES: Pancreatic stereotactic body radiation therapy (SBRT) is limited to gross tumor without elective coverage for subclinical disease. Given a better understanding of recurrence patterns, we hypothesized that the addition of elective nodal irradiation (ENI) to pancreatic SBRT would be tolerable and would decrease locoregional progression.MATERIALS/METHODS: We conducted a retrospective 1:2 propensity-matched cohort study to compare toxicity and locoregional progression among patients treated with pancreatic SBRT with or without ENI. In the SBRT+ENI cohort, an elective target volume was delineated per RTOG guidelines and treated to 25 Gy in 5 fractions alongside 40 Gy in 5 fractions to gross disease. The primary outcome was the cumulative incidence of locoregional progression, with death as a competing risk.RESULTS: Among 135 candidate controls treated with SBRT alone, 100 were propensity-matched to 50 patients treated with SBRT+ENI. All patients completed SBRT. Median potential radiographic follow-up was 28 months. The incidence of late and serious acute toxicity were similar between matched cohorts. However, SBRT+ENI was associated with a statistically significant increase in acute grade 1-2 nausea (60% vs. 20%, p<0.001). The 24-month cumulative incidences of locoregional progression with and without ENI were 22.6% (95% confidence interval [CI]: 10.0-35.1%) vs. 44.6% (95% CI: 34.8-54.4%, multivariable-adjusted hazard ratio 0.39, 95% CI 0.18-0.87, p=0.021). This was stable in sensitivity analyses of uniform prescription dose, multiagent chemotherapy, and resectability. There were fewer peripancreatic (0% vs. 7%), porta hepatis (2% vs. 7%), and peri-aortic/aortocaval (5% vs. 12%) recurrences after SBRT+ENI, but no difference in survival.CONCLUSIONS: Pancreatic SBRT+ENI was tolerable and did not increase late or serious acute toxicity relative to a matched cohort undergoing SBRT alone, but did increase acute grade 1-2 nausea. The addition of ENI to SBRT was associated with decreased locoregional progression but not improved survival. Further studies are warranted to determine if ENI offers meaningful benefit.

    View details for DOI 10.1016/j.ijrobp.2021.07.1698

    View details for PubMedID 34348171

  • A Longitudinal Telehealth Curriculum for Radiation Oncology Centers in Low and Middle-Income Countries Transitioning from 2D to 3D External Beam Radiation Therapy Yang, F., Carter, R., Ahmed, S., Plautz, T., Dubrowski, P., Wadi-Ramahi, S., Ashmeg, S., Ascoli, F., Wakefield, D., Adamson, J., Li, B. AMER ASSOC CANCER RESEARCH. 2021
  • CT-less electron radiotherapy simulation and planning with a consumer 3D camera. Journal of applied clinical medical physics Skinner, L., Knopp, R., Wang, Y., Dubrowski, P., Bush, K. K., Limmer, A., Trakul, N., Million, L., Marquez, C. M., Yu, A. S. 2021

    Abstract

    PURPOSE: Electron radiation therapy dose distributions are affected by irregular body surface contours. This study investigates the feasibility of three-dimensional (3D) cameras to substitute for the treatment planning computerized tomography (CT) scan by capturing the body surfaces to be treated for accurate electron beam dosimetry.METHODS: Dosimetry was compared for six electron beam treatments to the nose, toe, eye, and scalp using full CT scan, CT scan with Hounsfield Unit (HU) overridden to water (mimic 3D camera cases), and flat-phantom techniques. Radiation dose was prescribed to a depth on the central axis per physician's order, and the monitor units (MUs) were calculated. The 3D camera spatial accuracy was evaluated by comparing the 3D surface of a head phantom captured by a 3D camera and that generated with the CT scan in the treatment planning system. A clinical case is presented, and MUs were calculated using the 3D camera body contour with HU overridden to water.RESULTS: Across six cases the average change in MUs between the full CT and the 3Dwater (CT scan with HU overridden to water) calculations was 1.3% with a standard deviation of 1.0%. The corresponding hotspots had a mean difference of 0.4% and a standard deviation of 1.9%. The 3D camera captured surface of a head phantom was found to have a 0.59mm standard deviation from the surface derived from the CT scan. In-vivo dose measurements (213±8cGy) agreed with the 3D-camera planned dose of 209±6cGy, compared to 192±6cGy for the flat-phantom calculation (same MUs).CONCLUSIONS: Electron beam dosimetry is affected by irregular body surfaces. 3D cameras can capture irregular body contours which allow accurate dosimetry of electron beam treatment as an alternative to costly CT scans with no extra exposure to radiation. Tools and workflow for clinical implementation are provided.

    View details for DOI 10.1002/acm2.13283

    View details for PubMedID 34042253

  • A robotically assisted 3D printed quality assurance lung phantom for Calypso. Physics in medicine and biology Capaldi, D. P., Skinner, L. B., Dubrowski, P. n., Zhang, H. n., Xing, L. n., Chuang, C. F., Loo, B. W., Bush, K. K., Fahimian, B. P., Yu, A. S. 2021

    Abstract

    Purpose:Radiation dose delivered to targets located near the upper-abdomen or in the thorax are significantly affected by respiratory-motion. Relatively large-margins are commonly added to compensate for this motion, limiting radiation-dose-escalation. Internal-surrogates of target motion, such as a radiofrequency (RF) tracking system, i.e. Calypso® System, are used to overcome this challenge and improve normal-tissue sparing. RF tracking systems consist of implanting transponders in the vicinity of the tumor to be tracked using radiofrequency-waves. Unfortunately, although the manufacture provides a universal quality-assurance (QA) phantom, QA-phantoms specifically for lung-applications are limited, warranting the development of alternative solutions to fulfil the tests mandated by AAPM's TG142. Accordingly, our objective was to design and develop a motion-phantom to evaluate Calypso for lung-applications that allows the Calypso® Beacons to move in different directions to better simulate true lung-motion.Methods and Materials:A Calypso lung QA-phantom was designed, and 3D-printed. The design consists of three independent arms where the transponders were attached. A pinpoint-chamber with a buildup-cap was also incorporated. A 4-axis robotic arm was programmed to drive the motion-phantom to mimic breathing. After acquiring a four-dimensional-computed-tomography (4DCT) scan of the motion-phantom, treatment-plans were generated and delivered on a Varian TrueBeam® with Calypso capabilities. Stationary and gated-treatment plans were generated and delivered to determine the dosimetric difference between gated and non-gated treatments. Portal cine-images were acquired to determine the temporal-accuracy of delivery by calculating the difference between the observed versus expected transponders locations with the known speed of the transponders' motion.Results:Dosimetric accuracy is better than TG142 tolerance of 2%. Temporal accuracy is greater than, TG142 tolerance of 100ms for beam-on, but less than 100ms for beam-hold.Conclusions:The robotic QA-phantom designed and developed in this study provides an independent phantom for performing Calypso lung-QA for commissioning and acceptance testing of Calypso for lung treatments.

    View details for DOI 10.1088/1361-6560/abebaa

    View details for PubMedID 33657537

  • An integrated quality assurance phantom for frameless single-isocenter multitarget stereotactic radiosurgery. Physics in medicine and biology Capaldi, D. P., Skinner, L. B., Dubrowski, P. n., Yu, A. S. 2020

    Abstract

    Purpose:Brain stereotactic-radiosurgery (SRS) treatments require multiple quality-assurance (QA) procedures to ensure accurate and precise treatment delivery. As single-isocenter multitarget SRS treatments become more popular, the quantification of off-axis accuracy of the linear-accelerator is crucial. In this study, a novel brain SRS integrated phantom was developed and validated to enable SRS QA with a single phantom to facilitate implementation of a frameless single-isocenter, multitarget SRS program. This phantom combines the independent verification of each positioning system, the Winston-Lutz, off-axis accuracy evaluation (i.e. off-axis Winston-Lutz), and the dosimetric accuracy utilizing both point-dose-measurements as well as film-measurement, without moving the phantom.Methods and Materials:A novel 3D-printed phantom, coinedOneIso, was designed with a movable insert which can switch between the Winston-Lutz test target and dose measurement without moving the phantom itself. For dose verification, eight brain SRS clinical-treatment-plans with 10MV Flattening-Filter-Free (FFF) beams were delivered on a Varian TrueBeam with a high-definition-multi-leaf-collimator (HD-MLC). Radiochromic film and pinpoint ion chamber comparison measurements were made between the OneIso and solid water (SW) phantom setups. For the off-axis Winston-Lutz measurements, a row of off-axis ball-bearings (BBs) was integrated into the OneIso. To quantify the spatial accuracy versus distance from isocenter, two-dimensional displacements were calculated between the planned and delivered BB locations relative to their respective MLC defined field border.Results:OneIso and the SW phantoms agree within 1%, for both film and point-dose measurements. OneIso identified a reduction in spatial accuracy further away from isocenter. Differences increased as distance from isocenter increased exceeding recommended SRS accuracy tolerances at 3-4cm away from isocenter.Conclusions:OneIso provides a streamlined, single-setup workflow for single-isocenter multitarget frameless linac-based SRS QA. Additionally, with the ability to quantify off-axis spatial-discrepancies, we can determine limitations on the maximum distance between targets to ensure a single-isocenter multitarget SRS program meets recommended guidelines.

    View details for DOI 10.1088/1361-6560/ab8534

    View details for PubMedID 32235050

  • A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems. Medical physics Yu, A. S., Fowler, T. L., Dubrowski, P. 2018

    Abstract

    PURPOSE: Various localization and positioning systems utilizing radiographic or nonradiographic methods have been developed to improve the accuracy of radiation treatment. Each quality assurance (QA) procedure requires its own phantom and is independent from each other, so the deviation between each system is unavailable. The purpose of this work is to develop and evaluate a single-integrated QA phantom for different localization and positioning systems.METHODS: The integrated phantom was designed in three-dimensional (3D) CAD software and 3D printed. The phantom was designed with laser alignment marks, a raised letter "S" on the anterior surface for optical surface monitoring system registration, a core for radiofrequency (RF) tracking system alignment, eight internal fiducials for image alignment, and an isocentric bearing for Winston-Lutz test. Tilt legs and rotational stage were designed for rotational verification of optical surface mapping system and RF tracking system, respectively. The phantom was scanned using a CT scanner and a QA plan was created. This prototype phantom was evaluated against established QA techniques.RESULTS: The QA result between the proposed procedure and established QA technique are 1.12 ± 0.31 and 1.14 ± 0.31 mm, respectively, for RF tracking system and 0.18 ± 0.06 and 0.18 ± 0.05 mm for Winston-Lutz test. There is no significant difference for the QA results between the established QA and proposed procedure (P > 0.05, t test). The accuracy of rotational verification for surface mapping system and RF tracking system are less than 0.5 and 1° compared the predefined value. The isocenter deviation of each location system is around l mm.CONCLUSION: We have designed and evaluated a novel-integrated phantom for radiographic and nonradiographic localization and positioning systems for radiotherapy. With this phantom, we will reduce the variation in measurements and simplify the QA procedures.

    View details for PubMedID 29730884