Shan X. Wang
Leland T. Edwards Professor in the School of Engineering and Professor of Electrical Engineering and, by courtesy, of Radiology (Molecular Imaging Program at Stanford)
Materials Science and Engineering
Web page: http://wanggroup.stanford.edu
Bio
Dr. Wang is the Leland T. Edwards Professor in the School of Engineering and Professor of Materials Science and Engineering, jointly of Electrical Engineering and, by courtesy, of Radiology (Molecular Imaging Program at Stanford). He directs the Center for Magnetic Nanotechnology and is a leading expert in biosensors, information storage and spintronics. His research and inventions span across a variety of areas including magnetic biochips, in vitro diagnostics, cancer biomarkers, magnetic nanoparticles, magnetic sensors, magnetoresistive random access memory, and magnetic integrated inductors. He has over 300 publications, and holds 70 issued or pending patents in these and interdisciplinary areas. He was named an inaugural Fred Terman Fellow, and was elected a Fellow of the Institute of Electrical and Electronics Engineers (IEEE), a Fellow of American Physical Society (APS) and a Fellow of National Academy of Inventors (FNAI) for his seminal contributions to magnetic materials, nanosensors and cancer diagnostics. His team won the Grand Challenge Exploration Award from Gates Foundation (2010), the XCHALLENGE Distinguished Award (2014), and the Bold Epic Innovator Award from the XPRIZE Foundation (2017). He coauthored two textbooks: Magnetic Information Storage Technology (Academic Press) and Biochips and Medical Imaging (Wiley).
Dr. Wang cofounded six high-tech startups in Silicon Valley, including Curve Biosciences, Magic Lifescience, MagArray, and Nvigen.In 2023, Curve Biosciences demonstrated a circulating tumor DNA NGS assay, enabling early detection of liver cancer from cirrhosis with unprecedented sensitivity and specificity (both ≥95%); Magic received a Gates Foundation grant and launched clinical trials to seek FDA clearance for its rapid NAT products at POC. In 2018 MagArray launched a first of its kind lung cancer early diagnostic assay based on protein cancer biomarkers and support vector machine (SVM). Through his participation and leadership in Cancer Nanotechnology Excellence, Semiconductor Research Corp (SRC) and Microelectronics Commons, he is actively engaged in the transformative R&D of healthcare, energy-efficient computing and edge AI.
Academic Appointments
-
Professor, Materials Science and Engineering
-
Professor, Electrical Engineering
-
Professor (By courtesy), Radiology - Rad/Molecular Imaging Program at Stanford
-
Member, Bio-X
-
Member, Cardiovascular Institute
-
Affiliate, Precourt Institute for Energy
-
Member, Stanford Cancer Institute
-
Affiliate, Stanford Woods Institute for the Environment
-
Member, Wu Tsai Neurosciences Institute
Administrative Appointments
-
Associate Chair, Materials Science and Engineering (2014 - 2019)
Honors & Awards
-
Fellow, National Academy of Inventors (2021)
-
Leland T. Edwards Professor, Stanford University (2018)
-
Bold Epic Innovator Award, XPRIZE Foundation (2017)
-
Nokia Sensing XCHALLENGE Distinguished Award, XPRIZE Foundation (2014)
-
Faculty Award, IBM (2013-4)
-
Faculty Fellow, Stanford Center at Peking University (SCPKU) (2013)
-
Fellow, American Physical Society (APS) (2012)
-
Fellow, The Institute of Electrical and Electronics Engineers (IEEE) (2009)
-
Keck Futures Initiative Award, National Academies (2006-7)
-
Distinguished Lecturer, IEEE Magnetics Society (2001)
-
Partnership Award, IBM (1999)
-
Inaugural Frederick Terman Faculty Fellow, Stanford University (1994-97)
-
CUSPEA Scholarship, Organized by Nobel Laureate TD Lee (1986)
Program Affiliations
-
Stanford SystemX Alliance
Professional Education
-
PhD, Carnegie Mellon University, Electrical and Computer Engineering (1993)
Community and International Work
-
Fellow, Center for Innovation in Global Health (CIGH), Asia, Africa, America
Topic
Mobile Health, POCT
Partnering Organization(s)
Stanford University
Location
International
Ongoing Project
Yes
Opportunities for Student Involvement
Yes
Current Research and Scholarly Interests
Dr. Wang is the Leland T. Edwards Professor in the School of Engineering, Stanford University. He is a Professor of Materials Science & Engineering and jointly a Professor of Electrical Engineering, and by courtesy, a Professor of Radiology (Stanford School of Medicine). He directs the Center for Magnetic Nanotechnology and is a leading expert in biosensors, information storage and spintronics. His research and inventions span across a variety of areas including magnetic biochips, in vitro diagnostics, cancer biomarkers, magnetic nanoparticles, magnetic sensors, magnetoresistive random access memory, and magnetic integrated inductors. He has over 300 publications, and holds 70 issued or pending patents in these and interdisciplinary areas. He was named an inaugural Fred Terman Fellow, and was elected a Fellow of the Institute of Electrical and Electronics Engineers (IEEE), a Fellow of American Physical Society (APS) and a Fellow of National Academy of Inventors for his seminal contributions to magnetic materials, nanosensors and cancer diagnostics. His team won the Grand Challenge Exploration Award from Gates Foundation (2010), the XCHALLENGE Distinguished Award (2014), and the Bold Epic Innovator Award from the XPRIZE Foundation (2017). He coauthored two textbooks: Magnetic Information Storage Technology (Academic Press) and Biochips and Medical Imaging (Wiley).
Dr. Wang cofounded six high-tech startups in Silicon Valley, including Curve Biosciences, Magic Lifescience, MagArray, and Flux Biosciences. In 2018 MagArray launched a first of its kind lung cancer early diagnostic assay based on protein cancer biomarkers and support vector machine (SVM). In 2023, Curve Biosciences demonstrated a circulating tumor DNA NGS assay, enabling early detection of liver cancer from cirrhosis with unprecedented sensitivity and specificity (both ≥95%). Through his participation and leadership in Cancer Nanotechnology Excellence and Semiconductor Research Corp (SRC) programs, he is actively engaged in the transformative research of healthcare and is developing emerging memories for energy efficient computing and edge AI.
Dr. Wang obtained his PhD in Electrical and Computer Engineering from Carnegie Mellon University in 1993, MS in Physics from Iowa State University in 1988, and BS in Physics from the University of Science and Technology of China in 1986.
Clinical Trials
-
COMT Activity and Hypnotizability
Not Recruiting
Hypnosis is an effective pain management tool for surgery that can reduce opioid use up to 40%. COMT single nucleotide polymorphisms (SNPs) can predict pain sensitivity and opioid use perioperatively, and may also be associated with hypnotizability or response to hypnotic analgesia. Analyzing COMT haplotypes from DNA extracted from saliva or blood using a giant magnetoresistive (GMR) nanotechnology platform may be faster, less expensive, and at least as accurate as pyrosequencing. This study aims to validate a multi-SNP point-of-care (POC) GMR assay for the rapid genotyping of SNPs predictive of COMT activity, and test the feasibility of using COMT activity as a biomarker for hypnotizability and/or response to hypnotic analgesia.
Stanford is currently not accepting patients for this trial. For more information, please contact Jessie Kittle, MD, 800-000-0000.
-
Identification of Circulating Tumor Cells in the Peripheral Blood of Lung Cancer Patients
Not Recruiting
The primary aim of this study is to determine whether we can identify human lung cancer tumor cells in the peripheral blood of lung cancer patients.
Stanford is currently not accepting patients for this trial. For more information, please contact Lisa Zhou, 650-736-4112.
2024-25 Courses
- Biochips and Medical Imaging
EE 225, MATSCI 225 (Win) - Great Inventions That Matter
MATSCI 83N (Aut) -
Independent Studies (15)
- Directed Investigation
BIOE 392 (Aut, Win, Spr, Sum) - Directed Study
BIOE 391 (Aut, Win, Spr, Sum) - Graduate Independent Study
MATSCI 399 (Aut, Win, Spr, Sum) - Master's Research
MATSCI 200 (Aut, Win, Spr, Sum) - Master's Thesis and Thesis Research
EE 300 (Aut, Win, Spr, Sum) - Participation in Materials Science Teaching
MATSCI 400 (Aut, Win, Spr) - Ph.D. Research
MATSCI 300 (Aut, Win, Spr, Sum) - Practical Training
MATSCI 299 (Aut, Win, Spr, Sum) - Special Studies and Reports in Electrical Engineering
EE 191 (Aut, Win, Spr, Sum) - Special Studies and Reports in Electrical Engineering
EE 391 (Aut, Win, Spr, Sum) - Special Studies and Reports in Electrical Engineering (WIM)
EE 191W (Aut, Win, Spr, Sum) - Special Studies or Projects in Electrical Engineering
EE 190 (Aut, Win, Spr, Sum) - Special Studies or Projects in Electrical Engineering
EE 390 (Aut, Win, Spr, Sum) - Undergraduate Independent Study
MATSCI 100 (Aut, Win, Spr, Sum) - Undergraduate Research
MATSCI 150 (Aut, Win, Spr, Sum)
- Directed Investigation
-
Prior Year Courses
2023-24 Courses
- Biochips and Medical Imaging
EE 225, MATSCI 225 (Win) - Great Inventions That Matter
MATSCI 83N (Aut) - New Methods in Thin Film Synthesis
MATSCI 312 (Spr)
2022-23 Courses
- Biochips and Medical Imaging
EE 225, MATSCI 225, SBIO 225 (Win) - Great Inventions That Matter
MATSCI 83N (Aut) - New Methods in Thin Film Synthesis
MATSCI 312 (Spr)
2021-22 Courses
- Great Inventions That Matter
MATSCI 83N (Aut)
- Biochips and Medical Imaging
Stanford Advisees
-
Doctoral Dissertation Reader (AC)
Ziad Ali, Jason Saunders, Prima Dewi Sinawang, Haotian Su, Steven Yee -
Postdoctoral Faculty Sponsor
Fen Xue -
Doctoral Dissertation Advisor (AC)
Katie Antilla, Jacob Bryan, Christopher Choi, Sydney Fultz-Waters, William Hwang -
Doctoral Dissertation Co-Advisor (AC)
Kenneth Brinson -
Master's Program Advisor
Hiranmai Mohan, Jane Nguyen, Will Salisbury -
Doctoral (Program)
Myungheon(Young) Chin, Vivek Lam, Linkai Li, Itamar Terem -
Postdoctoral Research Mentor
Fen Xue
All Publications
-
On-Device Continual Learning With STT-Assisted-SOT MRAM-Based In-Memory Computing
IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS
2024; 43 (8): 2393-2404
View details for DOI 10.1109/TCAD.2024.3371268
View details for Web of Science ID 001273931700016
-
Thermal optimization of two-terminal SOT-MRAM
JOURNAL OF APPLIED PHYSICS
2024; 136 (1)
View details for DOI 10.1063/5.0211620
View details for Web of Science ID 001260943300007
-
The role of magnetic anisotropy in the magnetoresistance of Cr<sub>2</sub>O<sub>3</sub>/Al<sub>2</sub>O<sub>3</sub> thin film antiferromagnets
AIP ADVANCES
2024; 14 (3)
View details for DOI 10.1063/5.0195641
View details for Web of Science ID 001181003200006
-
Evaluation of restriction and Cas endonuclease kinetics using matrix-insensitive magnetic biosensors.
Biosensors & bioelectronics
2024; 249: 116017
Abstract
The enzymatic actions of endonucleases in vivo can be altered due to bound substrates and differences in local environments, including enzyme concentration, pH, salinity, ionic strength, and temperature. Thus, accurate estimation of enzymatic reactions in vivo using matrix-dependent methods in solution can be challenging. Here, we report a matrix-insensitive magnetic biosensing platform that enables the measurement of endonuclease activity under different conditions with varying pH, salinity, ionic strength, and temperature. Using biosensor arrays and orthogonal pairs of oligonucleotides, we quantitatively characterized the enzymatic activity of EcoRI under different buffer conditions and in the presence of inhibitors. To mimic a more physiological environment, we monitored the sequence-dependent star activity of EcoRI under unconventional conditions. Furthermore, enzymatic activity was measured in cell culture media, saliva, and serum. Last, we estimated the effective cleavage rates of Cas12a on anchored single-strand DNAs using this platform, which more closely resembles in vivo settings. This platform will facilitate precise characterization of restriction and Cas endonucleases under various conditions.
View details for DOI 10.1016/j.bios.2024.116017
View details for PubMedID 38262299
-
Unconventional Spin-Orbit Torques (SOT) in Sputtered Materials for High Density High Speed MRAM
IEEE. 2024
View details for DOI 10.1109/VLSITSA60681.2024.10546440
View details for Web of Science ID 001253001400099
-
Real-time temperature correction for magnetoresistive biosensors integrated with temperature modulator.
Biosensors & bioelectronics: X
2023; 14
Abstract
Magnetoresistance-based biosensors utilize changes in electrical resistance upon varying magnetic fields to measure biological molecules or events involved with magnetic tags. However, electrical resistance fluctuates with temperature. To decouple unwanted temperature-dependent signals from the signal of interest, various methods have been proposed to correct signals from magnetoresistance-based biosensors. Yet, there is still a need for a temperature correction method capable of instantaneously correcting signals from all sensors in an array, as multiple biomarkers need to be detected simultaneously with a group of sensors in a central laboratory or point-of-care setting. Here we report a giant magnetoresistive biosensor system that enables real-time temperature correction for individual sensors using temperature correction coefficients obtained through a temperature sweep generated by an integrated temperature modulator. The algorithm with individual temperature correction coefficients obviously outperformed that using the average temperature correction coefficient. Further, temperature regulation did not eliminate temperature-dependent signals completely. To demonstrate that the method can be used in biomedical applications where large temperature variations are involved, binding kinetics experiments and melting curve analysis were conducted with the temperature correction method. The method successfully removed all temperature-dependent artifacts and thus produced more precise kinetic parameters and melting temperatures of DNA hybrids.
View details for DOI 10.1016/j.biosx.2023.100356
View details for PubMedID 37799506
-
Longitudinal analysis of anti-SARS-CoV-2 neutralizing antibody (NAb) titers in vaccinees using a novel giant magnetoresistive (GMR) assay.
Sensors and actuators. B, Chemical
2023; 387: 133773
Abstract
The COVID-19 pandemic has highlighted the need to monitor important correlates of immunity on a population-wide level. To this end, we have developed a competitive assay to assess neutralizing antibody (NAb) titer on the giant magnetoresistive (GMR) biosensor platform. We compared the clinical performance of our biosensor with established techniques such as Ortho's VITROS Anti-SARS-CoV-2 IgG Quantitative Antibody test. Results obtained between the VITROS test and the GMR assay showed correlation (r=-0.93). We then validated the assay with patient plasma samples that had been tested using focus reduction neutralization testing (FRNT). The results obtained from our GMR assay exhibit a previously identified trend of increased NAb titers 2 weeks post-vaccination. We further evaluated NAb titers 6 months post-vaccination and observed waning neutralizing antibody titers over that time in vaccinated patients. In addition, we calibrated our assay to an arbitrary unit (IU/mL) using World Health Organization (WHO) reference plasma provided by the National Institute of Biological Standards and Control (NIBSC). Our biosensor provides highly specific and sensitive results in serum and plasma with analytical, clinical, and point-of-care (POC) applications due to quick turnaround times on samples and the cost-effectiveness of the platform.
View details for DOI 10.1016/j.snb.2023.133773
View details for PubMedID 37056483
-
Field-free spin-orbit torque switching assisted by in-plane unconventional spin torque in ultrathin [Pt/Co]N.
Nature communications
2023; 14 (1): 3932
Abstract
Electrical manipulation of magnetization without an external magnetic field is critical for the development of advanced non-volatile magnetic-memory technology that can achieve high memory density and low energy consumption. Several recent studies have revealed efficient out-of-plane spin-orbit torques (SOTs) in a variety of materials for field-free type-z SOT switching. Here, we report on the corresponding type-x configuration, showing significant in-plane unconventional spin polarizations from sputtered ultrathin [Pt/Co]N, which are either highly textured on single crystalline MgO substrates or randomly textured on SiO2 coated Si substrates. The unconventional spin currents generated in the low-dimensional Co films result from the strong orbital magnetic moment, which has been observed by X-ray magnetic circular dichroism (XMCD) measurement. The x-polarized spin torque efficiency reaches up to -0.083 and favors complete field-free switching of CoFeB magnetized along the in-plane charge current direction. Micromagnetic simulations additionally demonstrate its lower switching current than type-y switching, especially in narrow current pulses. Our work provides additional pathways for electrical manipulation of spintronic devices in the pursuit of high-speed, high-density, and low-energy non-volatile memory.
View details for DOI 10.1038/s41467-023-39649-1
View details for PubMedID 37402728
-
Rapid, Point-of-Care Host-Based Gene Expression Diagnostics Using Giant Magnetoresistive Biosensors.
ACS sensors
2023
Abstract
Host-based gene expression analysis is a promising tool for a broad range of clinical applications, including rapid infectious disease diagnostics and real-time disease monitoring. However, the complex instrumentation requirements and slow turnaround-times associated with traditional gene expression analysis methods have hampered their widespread adoption at the point-of-care (POC). To overcome these challenges, we have developed an automated and portable platform that utilizes polymerase chain reaction (PCR) and giant magnetoresistive (GMR) biosensors to perform rapid multiplexed, targeted gene expression analysis at the POC. As proof-of-concept, we utilized our platform to amplify and measure the expression of four genes (HERC5, HERC6, IFI27, and IFIH1) that were previously shown to be upregulated in hosts infected with influenza viruses. The compact instrument conducted highly automated PCR amplification and GMR detection to measure the expression of the four genes in multiplex, then utilized Bluetooth communication to relay results to users on a smartphone application. To validate the platform, we tested 20 cDNA samples from symptomatic patients that had been previously diagnosed as either influenza-positive or influenza-negative using a RT-PCR virology panel. A non-parametric Mann-Whitney test revealed that day 0 (day of symptom onset) gene expression was significantly different between the two groups (p < 0.0001, n = 20). Hence, we preliminarily demonstrated that our platform could accurately discriminate between symptomatic influenza and non-influenza populations based on host gene expression in 30 min. This study not only establishes the potential clinical utility of our proposed assay and device for influenza diagnostics but it also paves the way for broadscale and decentralized implementation of host-based gene expression diagnostics at the POC.
View details for DOI 10.1021/acssensors.3c00696
View details for PubMedID 37368357
-
A magnetic hydrogel for the efficient retrieval of kidney stone fragments during ureteroscopy.
Nature communications
2023; 14 (1): 3711
Abstract
Only 60-75% of conventional kidney stone surgeries achieve complete stone-free status. Up to 30% of patients with residual fragments <2 mm in size experience subsequent stone-related complications. Here we demonstrate a stone retrieval technology in which fragments are rendered magnetizable with a magnetic hydrogel so that they can be easily retrieved with a simple magnetic tool. The magnetic hydrogel facilitates robust in vitro capture of stone fragments of clinically relevant sizes and compositions. The hydrogel components exhibit no cytotoxicity in cell culture and only superficial effects on ex vivo human urothelium and in vivo mouse bladders. Furthermore, the hydrogel demonstrates antimicrobial activity against common uropathogens on par with that of common antibiotics. By enabling the efficient retrieval of kidney stone fragments, our method can lead to improved stone-free rates and patient outcomes.
View details for DOI 10.1038/s41467-023-38936-1
View details for PubMedID 37349287
View details for PubMedCentralID 5853829
-
Advances in point-of-care genetic testing for personalized medicine applications
BIOMICROFLUIDICS
2023; 17 (3): 031501
Abstract
Breakthroughs within the fields of genomics and bioinformatics have enabled the identification of numerous genetic biomarkers that reflect an individual's disease susceptibility, disease progression, and therapy responsiveness. The personalized medicine paradigm capitalizes on these breakthroughs by utilizing an individual's genetic profile to guide treatment selection, dosing, and preventative care. However, integration of personalized medicine into routine clinical practice has been limited-in part-by a dearth of widely deployable, timely, and cost-effective genetic analysis tools. Fortunately, the last several decades have been characterized by tremendous progress with respect to the development of molecular point-of-care tests (POCTs). Advances in microfluidic technologies, accompanied by improvements and innovations in amplification methods, have opened new doors to health monitoring at the point-of-care. While many of these technologies were developed with rapid infectious disease diagnostics in mind, they are well-suited for deployment as genetic testing platforms for personalized medicine applications. In the coming years, we expect that these innovations in molecular POCT technology will play a critical role in enabling widespread adoption of personalized medicine methods. In this work, we review the current and emerging generations of point-of-care molecular testing platforms and assess their applicability toward accelerating the personalized medicine paradigm.
View details for DOI 10.1063/5.0143311
View details for Web of Science ID 000981681300001
View details for PubMedID 37159750
View details for PubMedCentralID PMC10163839
-
Observation of anti-damping spin-orbit torques generated by in-plane and out-of-plane spin polarizations in MnPd3.
Nature materials
2023
Abstract
Large spin-orbit torques (SOTs) generated by topological materials and heavy metals interfaced with ferromagnets are promising for next-generation magnetic memory and logic devices. SOTs generated from y spin originating from spin Hall and Edelstein effects can realize field-free magnetization switching only when the magnetization and spin are collinear. Here we circumvent the above limitation by utilizing unconventional spins generated in a MnPd3 thin film grown on an oxidized silicon substrate. We observe conventional SOT due to y spin, and out-of-plane and in-plane anti-damping-like torques originated from z spin and x spin, respectively, in MnPd3/CoFeB heterostructures. Notably, we have demonstrated complete field-free switching of perpendicular cobalt via out-of-plane anti-damping-like SOT. Density functional theory calculations show that the observed unconventional torques are due to the low symmetry of the (114)-oriented MnPd3 films. Altogether our results provide a path toward realization of a practical spin channel in ultrafast magnetic memory and logic devices.
View details for DOI 10.1038/s41563-023-01522-3
View details for PubMedID 37012436
-
EFFICACY AND SAFETY OF A MAGNETIC HYDROGEL FOR STONE FRAGMENT REMOVAL: AN IN VITRO AND IN VIVO STUDY
LIPPINCOTT WILLIAMS & WILKINS. 2023: E819
View details for Web of Science ID 000994549502441
-
Energy Efficient Computing With High-Density, Field-Free STT-Assisted SOT-MRAM (SAS-MRAM)
IEEE TRANSACTIONS ON MAGNETICS
2023; 59 (3)
View details for DOI 10.1109/TMAG.2022.3224729
View details for Web of Science ID 000963514500004
-
Large Spin-Orbit-Torque Efficiency and Room-Temperature Magnetization Switching in SrIrO3/Co-Fe-B Heterostructures
PHYSICAL REVIEW APPLIED
2023; 23 (2)
View details for DOI 10.1103/PhysRevApplied.19.024076
View details for Web of Science ID 000943193100001
-
Point of care testing of enzyme polymorphisms for predicting hypnotizability and postoperative pain.
The Journal of molecular diagnostics : JMD
2023
Abstract
Hypnotizability is a stable trait that moderates the benefit of hypnosis for treating pain, but limited availability of hypnotizability testing deters widespread use of hypnosis. Inexpensive genotyping of 4 single nucleotide polymorphisms in the catechol-o-methyltransferase (COMT) gene was performed using giant magnetoresistive biosensors to determine if hypnotizable individuals can be identified for targeted hypnosis referrals. For individuals with the proposed 'optimal' COMT diplotypes, 89.5% score highly on the Hypnotic Induction Profile (OR = 6.12, 95%CI = 1.26-28.75), which identified 40.5% of the treatable population. Mean hypnotizability scores of the optimal group were significantly higher than the total population (p = 0.015 effect size = 0.60), an effect that was present in females (p = 0.0015, effect size = 0.83), but not in males (p = 0.28). In an exploratory cohort, optimal individuals also reported significantly higher postoperative pain scores (p = 0.00030, effect size = 1.93), indicating a greater need for treatment.
View details for DOI 10.1016/j.jmoldx.2023.01.002
View details for PubMedID 36702396
-
2-Terminal, High Density, and Magnetic Field Free SOT-MRAM
IEEE. 2023
View details for DOI 10.1109/TMRC59626.2023.10264011
View details for Web of Science ID 001090519000002
-
Quantitative and rapid detection of morphine and hydromorphone at the point of care by an automated giant magnetoresistive nanosensor platform.
Analytical and bioanalytical chemistry
2022
Abstract
Opioids, such as morphine and hydromorphone, are common pain management drugs with a high risk for addiction and adverse effects when delivered in large doses or administered too frequently. Point-of-care (POC) tools provide a solution to combat these negative outcomes through active monitoring of opioid concentrations in clinical settings. We demonstrate that giant magnetoresistive (GMR) nanosensors offer a quantitative, sensitive, and rapid solution for low-cost, sample-to-answer opioid detection at the POC. We show the robust nature of GMR nanosensors by developing a competitive morphine assay and characterizing it in saliva, blood, and plasma. We then implemented the assay on a fully automated POC GMR platform and demonstrated its duality to detect either morphine or hydromorphone using only 180muL of direct saliva without the need for pre-processing. In 35min from sample addition to result, the automated platform was controlled via smartphone and had seamless transmission of results via Bluetooth. The fully automated POC assay had a limit of detection of 3.43ng/mL for morphine and 3.49ng/mL for hydromorphone. The low-cost, 80-plex GMR nanosensor array coupled with the automated POC platform enables future development of multiplexed drug screening tools that can be deployed in clinical settings using a wide variety of non-invasive matrices.
View details for DOI 10.1007/s00216-022-04274-2
View details for PubMedID 35986104
-
Giant Orbital Anisotropy with Strong Spin-Orbit Coupling Established at the Pseudomorphic Interface of the Co/Pd Superlattice.
Advanced science (Weinheim, Baden-Wurttemberg, Germany)
2022: e2201749
Abstract
Orbital anisotropy at interfaces in magnetic heterostructures has been key to pioneering spin-orbit-related phenomena. However, modulating the interface's electronic structure to make it abnormally asymmetric has been challenging because of lack of appropriate methods. Here, the authors report that low-energy proton irradiation achieves a strong level of inversion asymmetry and unusual strain at interfaces in [Co/Pd] superlattices through nondestructive, selective removal of oxygen from Co3 O4 /Pd superlattices during irradiation. Structural investigations corroborate that progressive reduction of Co3 O4 into Co establishes pseudomorphic growth with sharp interfaces and atypically large tensile stress. The normal component of orbital to spin magnetic moment at the interface is the largest among those observed in layered Co systems, which is associated with giant orbital anisotropy theoretically confirmed, and resulting very large interfacial magnetic anisotropy is observed. All results attribute not only to giant orbital anisotropy but to enhanced interfacial spin-orbit coupling owing to the pseudomorphic nature at the interface. They are strongly supported by the observation of reversal of polarity of temperature-dependent Anomalous Hall signal, a signature of Berry phase. This work suggests that establishing both giant orbital anisotropy and strong spin-orbit coupling at the interface is key to exploring spintronic devices with new functionalities.
View details for DOI 10.1002/advs.202201749
View details for PubMedID 35748161
-
Magnetic supercluster particles for highly sensitive magnetic biosensing of proteins.
Mikrochimica acta
2022; 189 (7): 256
Abstract
Astrategy is reportedto improvethe detection limits of current giant magnetoresistance (GMR) biosensors by augmenting the effective magnetic moment that the magnetic tags on the biosensors can exert. Magnetic supercluster particles (MSPs), each of which consists of~1000 superparamagnetic cores, are prepared by a wet-chemical technique and are utilized to improve the limit of detection of GMR biosensors down to 17.6 zmol for biotin as a target molecule. This value is more than four orders of magnitude lower than that of the conventional colorimetric assay performed using the same set of reagents except for the signal transducer. The applicability of MSPs in immunoassay is further demonstrated by simultaneously detecting vascular endothelial growth factor (VEGF) and C-reactive protein (CRP) in a duplex assay format. MSPs outperform commercially available magnetic nanoparticles in terms of signal intensity and detection limit.
View details for DOI 10.1007/s00604-022-05354-x
View details for PubMedID 35697882
-
From saliva to SNP: non-invasive, point-of-care genotyping for precision medicine applications using recombinase polymerase amplification and giant magnetoresistive nanosensors.
Lab on a chip
2022
Abstract
Genetic testing is considered a cornerstone of the precision medicine paradigm. Genotyping of single nucleotide polymorphisms (SNPs) has been shown to provide insights into several important issues, including therapy selection and drug responsiveness. However, a scarcity of widely deployable and cost-effective genotyping tools has limited the integration of precision medicine into routine clinical practice. The objective of our work was to develop a portable, cost-effective, and automated platform that performs SNP genotyping at the point-of-care (POC). Using recombinase polymerase amplification (RPA) and giant magnetoresistive (GMR) nanosensors, we present a highly automated and multiplexed point-of-care platform that utilizes direct saliva for the qualitative genotyping of four SNPs (rs4633, rs4680, rs4818, rs6269) along the catechol-O-methyltransferase gene (COMT), which is associated with the modulation of pain sensitivity and perioperative opioid use. Using this approach, we successfully amplify, detect, and genotype all four of the SNPs, demonstrating 100% accordance between the experimental results obtained using the automated RPA and GMR genotyping assay and the results obtained using a COMT PCR genotyping assay that was formerly validated using pyrosequencing. This automated, portable, and multiplexed RPA and GMR assay shows great promise as a solution for SNP genotyping at the POC and reinforces the broad applications of magnetic nanotechnology in biomedicine.
View details for DOI 10.1039/d2lc00233g
View details for PubMedID 35537344
-
A GMR-based assay for quantification of the human response to influenza.
Biosensors & bioelectronics
2022; 205: 114086
Abstract
Detecting and quantifying the host transcriptional response to influenza virus infection can serve as a real-time diagnostic tool for clinical management. We have employed the multiplexing capabilities of GMR sensors to develop a novel assay based on the influenza metasignature (IMS), which can classify influenza infection based on transcript levels. We show that the assay can reliably detect ten IMS transcripts and distinguish subjects with naturally acquired influenza infection from those with other symptomatic viral infections (AUC 0.93, 95% CI: 0.82-1.00). Separately, we validated that the gene IFI27, not included in the IMS panel, has very high single-biomarker accuracy (AUC 0.95, 95% CI: 0.90-0.99) in stratifying patients with influenza. We demonstrate that a portable GMR biosensor can be used as a tool to diagnose influenza infection by measuring the host response, simultaneously highlighting the power of immune system metrics and advancing the field of gene expression-based diagnostics.
View details for DOI 10.1016/j.bios.2022.114086
View details for PubMedID 35192997
-
An automated and mobile magnetoresistive biosensor system for early hepatocellular carcinoma diagnosis.
Biosensors & bioelectronics
1800; 202: 113982
Abstract
Hepatocellular carcinoma (HCC) is one of the leading causes of cancer-related deaths worldwide. Most patients, however, are not diagnosed until advanced stage because early HCC lesions generally cause no overt symptoms, and the presence of cirrhosis adds another layer of complexity. While early diagnosis enables more therapeutic options and greatly improves survival rates, it is difficult to achieve. In order to detect early stage HCC, high-risk patients need to frequently measure serum biomarkers such as alpha-fetoprotein (AFP), and gold standards for detection involve less accessible and costly tests. In this work, we present an automated and mobile magnetoresistive biosensor system that allows quick, easy, and accurate detection of a panel of HCC related biomarkers. We first discuss the underlying principles of the giant magnetoresistive (GMR) biosensor system and its unique advantages in early detection of HCC. We also describe the development of hardware, software, and the bioassay, and demonstrate that it can perform an automated assay in 28min, providing both qualitative and quantitative results. The user only needs to manually add sample into a disposable cartridge and press a button on the smartphone app, without the need for direct interaction with reagent liquids, or lab skills such as pipetting. With its portability, high sensitivity, and ease-of-use, the presented biosensor system has the potential to empower both medical practitioners and patients to achieve early HCC diagnosis. Furthermore, the GMR biosensor platform can be adapted to detect other protein or DNA biomarkers beyond HCC, bringing the goals of accessible mobile health even closer to reality.
View details for DOI 10.1016/j.bios.2022.113982
View details for PubMedID 35033828
-
Performance Benchmarking of Spin-Orbit Torque Magnetic RAM (SOT-MRAM) for Deep Neural Network (DNN) Accelerators
IEEE. 2022: 73-76
View details for DOI 10.1109/IMW52921.2022.9779279
View details for Web of Science ID 000869001800019
-
A Self-Sustained Current Sensor for Smart Grid Application
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2021; 68 (12): 12810-12820
View details for DOI 10.1109/TIE.2020.3045590
View details for Web of Science ID 000692884200113
-
Spin-orbit torques of an in-plane magnetized system modulated by the spin transport in the ferromagnetic Co layer
APL MATERIALS
2021; 9 (10)
View details for DOI 10.1063/5.0048917
View details for Web of Science ID 000754460900001
-
Charge-spin interconversion in epitaxial Pt probed by spin-orbit torques in a magnetic insulator
PHYSICAL REVIEW MATERIALS
2021; 5 (6)
View details for DOI 10.1103/PhysRevMaterials.5.064404
View details for Web of Science ID 000661932200002
-
Large and robust charge-to-spin conversion in sputtered conductive WTex with disorder
MATTER
2021; 4 (5): 1639-1653
View details for DOI 10.1016/j.matt.2021.02.016
View details for Web of Science ID 000647646400003
-
Tunable spin-orbit torque efficiency in in-plane and perpendicular magnetized [Pt/Co](n) multilayer
APPLIED PHYSICS LETTERS
2021; 118 (4)
View details for DOI 10.1063/5.0034917
View details for Web of Science ID 000630477200002
-
Giant Magnetoresistive Nanosensor Analysis of Circulating Tumor DNA Epidermal Growth Factor Receptor Mutations for Diagnosis and Therapy Response Monitoring.
Clinical chemistry
2021
Abstract
Liquid biopsy circulating tumor DNA (ctDNA) mutational analysis holds great promises for precision medicine targeted therapy and more effective cancer management. However, its wide adoption is hampered by high cost and long turnaround time of sequencing assays, or by inadequate analytical sensitivity of existing portable nucleic acid tests to mutant allelic fraction in ctDNA.We developed a ctDNA Epidermal Growth Factor Receptor (EGFR) mutational assay using giant magnetoresistive (GMR) nanosensors. This assay was validated in 36 plasma samples of non-small cell lung cancer patients with known EGFR mutations. We assessed therapy response through follow-up blood draws, determined concordance between the GMR assay and radiographic response, and ascertained progression-free survival of patients.The GMR assay achieved analytical sensitivities of 0.01% mutant allelic fraction. In clinical samples, the assay had 87.5% sensitivity (95% CI = 64.0-97.8%) for Exon19 deletion and 90% sensitivity (95% CI = 69.9-98.2%) for L858R mutation with 100% specificity; our assay detected T790M resistance with 96.3% specificity (95% CI = 81.7-99.8%) with 100% sensitivity. After 2 weeks of therapy, 10 patients showed disappearance of ctDNA by GMR (predicted responders), whereas 3 patients did not (predicted nonresponders). These predictions were 100% concordant with radiographic response. Kaplan-Meier analysis showed responders had significantly (P < 0.0001) longer PFS compared to nonresponders (N/A vs. 12 weeks, respectively).The GMR assay has high diagnostic sensitivity and specificity and is well suited for detecting EGFR mutations at diagnosis and noninvasively monitoring treatment response at the point-of-care.
View details for DOI 10.1093/clinchem/hvaa307
View details for PubMedID 33393992
-
Challenges toward Low-Power SOT-MRAM
IEEE. 2021
View details for DOI 10.1109/IRPS46558.2021.9405127
View details for Web of Science ID 000672563100039
-
Ultrahigh Spin-Orbit Torque Efficiency at Spin Reorientation Transition State in Pt/Co Multilayer
IEEE. 2021
View details for DOI 10.1109/VLSI-TSA51926.2021.9440118
View details for Web of Science ID 000680845500054
-
A Novel Current Reconstruction Method Based on Elastic Net Regularization
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
2020; 69 (10): 7484–93
View details for DOI 10.1109/TIM.2020.2984819
View details for Web of Science ID 000571849100015
-
Diagnostics for SARS-CoV-2 detection: A comprehensive review of the FDA-EUA COVID-19 testing landscape.
Biosensors & bioelectronics
2020; 165: 112454
Abstract
The rapidly spreading outbreak of COVID-19 disease is caused by the SARS-CoV-2 virus, first reported in December 2019 in Wuhan, China. As of June 17, 2020, this virus has infected over 8.2 million people but ranges in symptom severity, making it difficult to assess its overall infection rate. There is a need for rapid and accurate diagnostics to better monitor and prevent the spread of COVID-19. In this review, we present and evaluate two main types of diagnostics with FDA-EUA status for COVID-19: nucleic acid testing for detection of SARS-CoV-2 RNA, and serological assays for detection of SARS-CoV-2 specific IgG and IgM patient antibodies, along with the necessary sample preparation for accurate diagnoses. In particular, we cover and compare tests such as the CDC 2019-nCoV RT-PCR Diagnostic Panel, Cellex's qSARS-CoV-2 IgG/IgM Rapid Test, and point-of-care tests such as Abbott's ID NOW COVID-19 Test. Antibody testing is especially important in understanding the prevalence of the virus in the community and to identify those who have gained immunity. We conclude by highlighting the future of COVID-19 diagnostics, which include the need for quantitative testing and the development of emerging biosensors as point-of-care tests.
View details for DOI 10.1016/j.bios.2020.112454
View details for PubMedID 32729549
-
Parametric Reconstruction of Multiple Line Currents Based on Magnetic Sensor Array
IEEE TRANSACTIONS ON MAGNETICS
2020; 56 (7)
View details for DOI 10.1109/TMAG.2020.2995500
View details for Web of Science ID 000543621800011
-
Flow Homogenization Enables a Massively Parallel Fluidic Design for High-throughput and Multiplexed Cell Isolation.
Advanced materials technologies
2020; 5 (5)
Abstract
Microfluidic devices are widely used for applications such as cell isolation. Currently, the most common method to improve throughput for microfluidic devices involves fabrication of multiple, identical channels in parallel. However, this 'numbering up' only occurs in one dimension, thereby limiting gains in volumetric throughput. In contrast, macro-fluidic devices permit high volumetric flow-rates but lack the finer control of microfluidics. Here, we demonstrate how a micro-pore array design enables flow homogenization across a magnetic cell capture device, thus creating a massively parallel series of micro-scale flow channels with consistent fluidic and magnetic properties, regardless of spatial location. This design enables scaling in 2-dimensions, allowing flow-rates exceeding 100 mL/hr while maintaining >90% capture efficiencies of spiked lung cancer cells from blood in a simulated circulating tumor cell system. Additionally, this design facilitates modularity in operation, which we demonstrate by combining two different devices in tandem for multiplexed cell separation in a single pass with no additional cell losses from processing.
View details for DOI 10.1002/admt.201900960
View details for PubMedID 33072854
View details for PubMedCentralID PMC7567302
-
Drive-Current-Free Switch With Internal Transduction in a Magneto Piezo-Electronic Transistor
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2020; 67 (4): 3257–66
View details for DOI 10.1109/TIE.2019.2910050
View details for Web of Science ID 000507307000072
-
Flow Homogenization Enables a Massively Parallel Fluidic Design for High-Throughput and Multiplexed Cell Isolation
ADVANCED MATERIALS TECHNOLOGIES
2020
View details for DOI 10.1002/admt.201900960
View details for Web of Science ID 000520259400001
-
Carbon-coated FeCo nanoparticles as sensitive magnetic-particle-imaging tracers with photothermal and magnetothermal properties.
Nature biomedical engineering
2020
Abstract
The low magnetic saturation of iron oxide nanoparticles, which are developed primarily as contrast agents for magnetic resonance imaging, limits the sensitivity of their detection using magnetic particle imaging (MPI). Here, we show that FeCo nanoparticles that have a core diameter of 10 nm and bear a graphitic carbon shell decorated with poly(ethylene glycol) provide an MPI signal intensity that is sixfold and fifteenfold higher than the signals from the superparamagnetic iron oxide tracers VivoTrax and Feraheme, respectively, at the same molar concentration of iron. We also show that the nanoparticles have photothermal and magnetothermal properties and can therefore be used for tumour ablation in mice, and that they have high optical absorbance in a broad near-infrared region spectral range (wavelength, 700-1,200 nm), making them suitable as tracers for photoacoustic imaging. As sensitive multifunctional and multimodal imaging tracers, carbon-coated FeCo nanoparticles may confer advantages in cancer imaging and hyperthermia therapy.
View details for DOI 10.1038/s41551-019-0506-0
View details for PubMedID 32015409
-
Spin-Orbit-Torque Material Exploration for Maximum Array-Level Read/Write Performance
IEEE. 2020
View details for DOI 10.1109/IEDM13553.2020.9371979
View details for Web of Science ID 000717011600090
-
A mountable toilet system for personalized health monitoring via the analysis of excreta.
Nature biomedical engineering
2020
Abstract
Technologies for the longitudinal monitoring of a person's health are poorly integrated with clinical workflows, and have rarely produced actionable biometric data for healthcare providers. Here, we describe easily deployable hardware and software for the long-term analysis of a user's excreta through data collection and models of human health. The 'smart' toilet, which is self-contained and operates autonomously by leveraging pressure and motion sensors, analyses the user's urine using a standard-of-care colorimetric assay that traces red-green-blue values from images of urinalysis strips, calculates the flow rate and volume of urine using computer vision as a uroflowmeter, and classifies stool according to the Bristol stool form scale using deep learning, with performance that is comparable to the performance of trained medical personnel. Each user of the toilet is identified through their fingerprint and the distinctive features of their anoderm, and the data are securely stored and analysed in an encrypted cloud server. The toilet may find uses in the screening, diagnosis and longitudinal monitoring of specific patient populations.
View details for DOI 10.1038/s41551-020-0534-9
View details for PubMedID 32251391
-
Piezoelectric-Piezoresistive Coupling MEMS Sensors for Measurement of Electric Fields of Broad Bandwidth and Large Dynamic Range
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2020; 67 (1): 551–59
View details for DOI 10.1109/TIE.2019.2893837
View details for Web of Science ID 000490858500050
-
Early multiplexed detection of cirrhosis by giant magnetoresistive biosensors with protein biomarkers.
ACS sensors
2020
Abstract
Liver cirrhosis is one of the leading causes of death in adults worldwide. It is highly prevalent in developing countries and is growing in prevalence in developed countries mostly due to chronic liver diseases, such as chronic hepatitis B and C, and alcoholic and nonalcoholic fatty liver disease. However, the prevalence of cirrhosis may be highly underestimated because early stages are asymptomatic and current early detection methods are inadequate. Here, we evaluate the potential of a set of novel cirrhotic protein biomarkers, including soluble intercellular adhesion molecule-1 (sICAM-1) and mac-2 binding protein glycosylation isomer (M2BPGi), for early detection of cirrhosis in a multiplexed assay using our giant magnetoresistive (GMR) sensor arrays. We evaluated the diagnostic performance of the biomarkers, individually and in combination, using multivariate logistic regression and random forest in a blinded proof-of-concept retrospective case-controlled study. The biomarkers in combination exhibited high diagnostic performance in both logistic regression and random forest models, with area under the curve (AUC) of 0.98 (0.94 - 1.00). In addition, the combination of biomarkers resulted in high sensitivity of 0.97 (0.95 - 1.00) and high specificity of 1.00. We showed that the diagnostic performance of our novel set of cirrhotic protein biomarkers on our multiplexed GMR sensor arrays is higher than the performance of currently used clinical biomarkers and factors (i.e. age, sex, alanine aminotransferase (ALT), aspartate aminotransferase (AST), etc.). With this combination of novel biomarkers and the GMR technology, we could potentially boost the diagnostic power of early cirrhosis detection.
View details for DOI 10.1021/acssensors.0c00232
View details for PubMedID 32896123
-
Materials Requirements of High-Speed and Low-Power Spin-Orbit-Torque Magnetic Random-Access Memory
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2020: 674–80
View details for DOI 10.1109/JEDS.2020.2984610
View details for Web of Science ID 000549302700005
-
Publisher Correction: A mountable toilet system for personalized health monitoring via the analysis of excreta.
Nature biomedical engineering
2020
Abstract
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
View details for DOI 10.1038/s41551-020-0562-5
View details for PubMedID 32382068
-
Method of inter-turn fault detection for next-generation smart transformers based on deep learning algorithm
HIGH VOLTAGE
2019; 4 (4): 282–91
View details for DOI 10.1049/hve.2019.0067
View details for Web of Science ID 000506150400005
-
Large voltage control of magnetic anisotropy in CoFeB/MgO/OX structures at room temperature
APL MATERIALS
2019; 7 (10)
View details for DOI 10.1063/1.5101002
View details for Web of Science ID 000501309200002
-
Efficient spin current generation in low-damping Mg(Al, Fe)(2)O-4 thin films
APPLIED PHYSICS LETTERS
2019; 115 (12)
View details for DOI 10.1063/1.5119726
View details for Web of Science ID 000487038900007
-
Current sensors based on GMR effect for smart grid applications
SENSORS AND ACTUATORS A-PHYSICAL
2019; 294: 8–16
View details for DOI 10.1016/j.sna.2019.05.002
View details for Web of Science ID 000472988800002
-
Identification of Partial Discharge Defects Based on Deep Learning Method
IEEE TRANSACTIONS ON POWER DELIVERY
2019; 34 (4): 1557–68
View details for DOI 10.1109/TPWRD.2019.2910583
View details for Web of Science ID 000477724800038
-
Overhead Transmission Line Parameter Reconstruction for UAV Inspection Based on Tunneling Magnetoresistive Sensors and Inverse Models
IEEE TRANSACTIONS ON POWER DELIVERY
2019; 34 (3): 819–27
View details for DOI 10.1109/TPWRD.2019.2891119
View details for Web of Science ID 000469337200004
-
Quantification of cDNA on GMR biosensor array towards point-of-care gene expression analysis
BIOSENSORS & BIOELECTRONICS
2019; 130: 338–43
View details for DOI 10.1016/j.bios.2018.09.050
View details for Web of Science ID 000461526200036
-
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
IEEE TRANSACTIONS ON MAGNETICS
2019; 55 (4)
View details for DOI 10.1109/TMAG.2019.2896036
View details for Web of Science ID 000461841100001
-
Self-healing of electrical damage in polymers using superparamagnetic nanoparticles
NATURE NANOTECHNOLOGY
2019; 14 (2): 151-+
View details for DOI 10.1038/s41565-018-0327-4
View details for Web of Science ID 000457765800017
-
Magneto-nanosensor smartphone platform for the detection of HIV and leukocytosis at point-of-care
NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE
2019; 16: 10–19
View details for DOI 10.1016/j.nano.2018.11.007
View details for Web of Science ID 000460167000002
-
Highly sensitive detection of DNA hypermethylation in melanoma cancer cells
BIOSENSORS & BIOELECTRONICS
2019; 124: 136–42
View details for DOI 10.1016/j.bios.2018.10.018
View details for Web of Science ID 000451935500017
-
An electrodynamic energy harvester with a 3D printed magnet and optimized topology
APPLIED PHYSICS LETTERS
2019; 114 (1)
View details for DOI 10.1063/1.5074123
View details for Web of Science ID 000455893000049
-
Improved detection of prostate cancer using a magneto-nanosensor assay for serum circulating autoantibodies.
PloS one
2019; 14 (8): e0221051
Abstract
PURPOSE: To develop a magneto-nanosensor (MNS) based multiplex assay to measure protein and autoantibody biomarkers from human serum for prostate cancer (CaP) diagnosis.MATERIALS AND METHODS: A 4-panel MNS autoantibody assay and a MNS protein assay were developed and optimized in our labs. Using these assays, serum concentration of six biomarkers including prostate-specific antigen (PSA) protein, free/total PSA ratio, as well as four autoantibodies against Parkinson disease 7 (PARK7), TAR DNA-binding protein 43 (TARDBP), Talin 1 (TLN1), and Caldesmon 1 (CALD1) and were analyzed. Human serum samples from 99 patients (50 with non-cancer and 49 with clinically localized CaP) were evaluated.RESULTS: The MNS assay showed excellent performance characteristics and no cross-reactivity. All autoantibody assays showed a statistically significant difference between CaP and non-cancer samples except for PARK7. The most significant difference was the combination of the four autoantibodies as a panel in addition to the free/total PSA ratio. This combination had the highest area under the curve (AUC)- 0.916 in ROC analysis.CONCLUSIONS: Our results suggest that this autoantibody panel along with PSA and free PSA have potential to segregate patients without cancer from those with prostate cancer with higher sensitivity and specificity than PSA alone.
View details for DOI 10.1371/journal.pone.0221051
View details for PubMedID 31404106
-
Interfacial engineering of SOT-MRAM to modulate atomic diffusion and enable PMA stability > 400 degrees C
IEEE. 2019
View details for Web of Science ID 000503374900025
-
An Automated, Quantitative, and Multiplexed Assay Suitable for Point-of-Care Hepatitis B Virus Diagnostics.
Scientific reports
2019; 9 (1): 15615
Abstract
Hepatitis B virus (HBV) infection has a global reach with high prevalence in resource-limited areas like China and Africa. HBV patients in these areas have limited access to the currently used, costly HBV assays, which are performed in centralized clinical laboratories using single-plexed assays with bulky and expensive instruments. We aim to overcome these limitations by developing a simple and affordable HBV diagnostic platform to allow for timelier diagnosis and intervention of HBV infection. Using giant magnetoresistive (GMR) biosensor chips, we developed an automated and multiplexed quantitative platform for the measurement of a panel of HBV serology markers, including HBV "e" antigen (HBeAg), HBV surface antigen (HBsAg), and the antibody against HBsAg (anti-HBs). Our assay platform was able to detect each HBV marker with high specificity and sensitivity (with three orders of magnitude in dynamic range for each marker). Blinded analysis of HBV patient sera showed excellent correlation between our multiplexed quantitative HBsAg results and the qualitative results obtained using FDA-approved immunoassays, as well as those obtained using quantitative, single-plexed, enzyme-linked immunosorbent assays (ELISAs). The portable, automated, multiplexed, quantitative HBV serology assay platform we designed shows great promise as a more accessible alternative for HBV screening, diagnosis, and treatment monitoring.
View details for DOI 10.1038/s41598-019-52147-z
View details for PubMedID 31666635
-
In Vitro Cancer Diagnostics
NANOTHERANOSTICS FOR CANCER APPLICATIONS
2019; 5: 109–32
View details for DOI 10.1007/978-3-030-01775-0_6
View details for Web of Science ID 000576804300006
-
GMR Spin-Valve Biosensors
SPINTRONICS HANDBOOK: SPIN TRANSPORT AND MAGNETISM: NANOSCALE SPINTRONICS AND APPLICATIONS, VOL 3, 2ND EDITION
2019: 471–97
View details for Web of Science ID 000576730200017
-
Self-healing of electrical damage in polymers using superparamagnetic nanoparticles.
Nature nanotechnology
2018
Abstract
High-voltage power transmission in electrical grids requires reliable and durable dielectric polymers for wire insulation1,2. Electrical treeing caused by high, local electric fields is a damaging process that leads to structure degradation and electrical conduction of dielectric materials, and ultimately, to catastrophic failure of the devices3-5. Here, we demonstrate that the addition of less than 0.1 volume per cent of superparamagnetic nanoparticles into a thermoplastic polymer enables the repair of regions damaged by electrical treeing and the restoration of the insulating properties. Under the application of an oscillating magnetic field, the embedded nanoparticles migrate to the electrical trees and generate a higher local temperature, which heals the electrical tree channels in the polymer. Our method allows us to regenerate the dielectric strength and electrical resistivity over multiple cycles of tree formation and healing, which could be used to increase the lifespan and sustainability of power cables for electronics and energy applications.
View details for PubMedID 30598524
-
Magneto-nanosensor Smartphone Platform for the Detection of HIV and Leukocytosis at Point-of-Care.
Nanomedicine : nanotechnology, biology, and medicine
2018
Abstract
The advent of personalized medicine has brought an increased interest in personal health among general consumers. As a result, there is a great need for user-centric point-of-care (POC) health devices. Such devices are equally pertinent in developing countries or resource-limited settings for performing diagnostic tests. However, current POC tests for diseases such as human immunodeficiency virus (HIV) or leukocytosis, do not provide adequate levels of sensitivity or do not exist at all. Here, we extend our mobile magneto-nanosensor platform to point-of-care HIV and leukocytosis detection. The platform can be multiplexed, and the circuitry enables portability and sensitivity in the POC setting. A smartphone application simplifies operation and provides guidance to facilitate self-testing. Commercially available POC test kits typically provide only qualitative or semi-quantitative results of a single analyte. The magneto-nanosensor platform can provide users with pleasant user-experience while demonstrating robust sensitive and specific multiplexed quantification and detection of common diseases.
View details for PubMedID 30502420
-
Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling
SCIENTIFIC REPORTS
2018; 8
View details for DOI 10.1038/s41598-018-34720-0
View details for Web of Science ID 000449367700039
-
Magnetoresistive biosensors with on-chip pulsed excitation and magnetic correlated double sampling.
Scientific reports
2018; 8 (1): 16493
Abstract
Giant magnetoresistive (GMR) sensors have been shown to be among the most sensitive biosensors reported. While high-density and scalable sensor arrays are desirable for achieving multiplex detection, scalability remains challenging because of long data acquisition time using conventional readout methods. In this paper, we present a scalable magnetoresistive biosensor array with an on-chip magnetic field generator and a high-speed data acquisition method. The on-chip field generators enable magnetic correlated double sampling (MCDS) and global chopper stabilization to suppress 1/f noise and offset. A measurement with the proposed system takes only 20ms, approximately 50* faster than conventional frequency domain analysis. A corresponding time domain temperature correction technique is also presented and shown to be able to remove temperature dependence from the measured signal without extra measurements or reference sensors. Measurements demonstrate detection of magnetic nanoparticles (MNPs) at a signal level as low as 6.92ppm. The small form factor enables the proposed platform to be portable as well as having high sensitivity and rapid readout, desirable features for next generation diagnostic systems, especially in point-of-care (POC) settings.
View details for PubMedID 30405155
-
Highly sensitive detection of DNA hypermethylation in melanoma cancer cells.
Biosensors & bioelectronics
2018; 124-125: 136–42
Abstract
Aberrant hypermethylation of CpG islands in the promoter region of tumor suppressor genes is a promising biomarker for early cancer detection. This methylation status is reflected in the methylation pattern of ctDNA shed from the primary tumor; however, to realize the full clinical utility of ctDNA methylation detection via liquid biopsy for early cancer diagnosis, improvements in the sensitivity and multiplexability of existing technologies must be improved. Additionally, the assay must be cheap and easy to perform in a clinical setting. We report the integration of methylation specific PCR (MSP) to melt curve analysis on giant magnetoresistive (GMR) biosensors to greatly enhance the sensitivity of our DNA hybridization assay for methylation detection. Our GMR sensor is functionalized with synthetic DNA probes that target methylated or unmethylated CpG sites in the MSP amplicon, and measures the difference in melting temperature (Tm) between the two probes (DeltaTm), giving an analytical limit of detection down to 0.1% methylated DNA in solution. Additionally, linear regression of DeltaTm's for serial dilutions of methylated:unmethylated mixtures allows for quantification of methylation percentage, which could have diagnostic and prognostic utility. Lastly, we performed multiplexed MSP on two different genes, and show the ability of our GMR assay to resolve this mixture, despite their amplicons' overlapping Tm's in standard EvaGreen melt analysis. The multiplexing ability of our assay and its enhanced sensitivity, without necessitating deep sequencing, represent important steps toward realizing an assay for the detection of methylated ctDNA in plasma for early cancer detection in a clinical setting.
View details for PubMedID 30366258
-
Quantification of cDNA on GMR biosensor array towards point-of-care gene expression analysis.
Biosensors & bioelectronics
2018
Abstract
Gene expression analysis at the point-of-care is important for rapid disease diagnosis, but traditional techniques are limited by multiplexing capabilities, bulky equipment, and cost. We present a gene expression analysis platform using a giant magnetoresistive (GMR) biosensor array, which allows multiplexed transcript detection and quantification through cost-effective magnetic detection. In this work, we have characterized the sensitivity, dynamic range, and quantification accuracy of Polymerase chain reaction (PCR)-amplified complementary DNA (cDNA) on the GMR for the reference gene GAPDH. A synthetic GAPDH single-stranded DNA (ssDNA) standard was used to calibrate the detection, and ssDNA dilutions were qPCR-amplified to obtain a standard curve. We demonstrate that the GMR platform provides a dynamic range of 4 orders of magnitude and a limit of detection of 1 pM and 0.1 pM respectively for 15 and 18-cycle amplified synthetic GAPDH PCR products. The quantitative results of GMR analysis of cell-line RNA were confirmed by qPCR.
View details for PubMedID 30269961
-
An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo
NATURE BIOMEDICAL ENGINEERING
2018; 2 (9): 696–705
View details for DOI 10.1038/s41551-018-0257-3
View details for Web of Science ID 000444282800014
-
Two-terminal spin-orbit torque magnetoresistive random access memory
NATURE ELECTRONICS
2018; 1 (9): 508–11
View details for DOI 10.1038/s41928-018-0131-z
View details for Web of Science ID 000454039700014
-
An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo.
Nature biomedical engineering
2018; 2 (9): 696-705
Abstract
The detection and analysis of rare blood biomarkers is necessary for early diagnosis of cancer and to facilitate the development of tailored therapies. However, current methods for the isolation of circulating tumour cells (CTCs) or nucleic acids present in a standard clinical sample of only 5-10 ml of blood provide inadequate yields for early cancer detection and comprehensive molecular profiling. Here, we report the development of a flexible magnetic wire that can retrieve rare biomarkers from the subject's blood in vivo at a much higher yield. The wire is inserted and removed through a standard intravenous catheter and captures biomarkers that have been previously labelled with injected magnetic particles. In a proof-of-concept experiment in a live porcine model, we demonstrate the in vivo labelling and single-pass capture of viable model CTCs in less than 10 s. The wire achieves capture efficiencies that correspond to enrichments of 10-80 times the amount of CTCs in a 5-ml blood draw, and 500-5,000 times the enrichments achieved using the commercially available Gilupi CellCollector.
View details for DOI 10.1038/s41551-018-0257-3
View details for PubMedID 30505627
View details for PubMedCentralID PMC6261517
-
A blood biomarker for monitoring response to anti-EGFR therapy.
Cancer biomarkers : section A of Disease markers
2018
Abstract
BACKGROUND AND OBJECTIVE: To monitor therapies targeted to epidermal growth factor receptors (EGFR) in non-small cell lung cancer (NSCLC), we investigated Peroxiredoxin 6 (PRDX6) as a biomarker of response to anti-EGFR agents.METHODS: We studied cells that are sensitive (H3255, HCC827) or resistant (H1975, H460) to gefitinib. PRDX6 was examined with either gefitinib or vehicle treatment using enzyme-linked immunosorbent assays. We created xenograft models from one sensitive (HCC827) and one resistant cell line (H1975) and monitored serum PRDX6 levels during treatment.RESULTS: PRDX6 levels in cell media from sensitive cell lines increased significantly after gefitinib treatment vs. vehicle, whereas there was no significant difference for resistant lines. PRDX6 accumulation over time correlated positively with gefitinib sensitivity. Serum PRDX6 levels in gefitinib-sensitive xenograft models increased markedly during the first 24 hours of treatment and then decreased dramatically during the following 48 hours. Differences in serum PRDX6 levels between vehicle and gefitinib-treated animals could not be explained by differences in tumor burden.CONCLUSIONS: Our results show that changes in serum PRDX6 during the course of gefitinib treatment of xenograft models provide insight into tumor response and such an approach offers several advantages over imaging-based strategies for monitoring response to anti-EGFR agents.
View details for PubMedID 29689709
-
Learning-based Data Analytics: Moving Towards Transparent Power Grids
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS
2018; 4 (1): 67–82
View details for DOI 10.17775/CSEEJPES.2017.01070
View details for Web of Science ID 000435855400008
-
Integrated Thin-Film Magnetoelectric Waveguide with Tun-able Resonance Frequency
IEEE. 2018
View details for Web of Science ID 000455204800500
-
An intravascular magnetic wire for the high-throughput retrieval of circulating tumour cells in vivo.
Nature biomedical engineering
2018; 2: 696–705
Abstract
The detection and analysis of rare blood biomarkers is necessary for early cancer diagnosis and to facilitate the development of tailored therapies. However, current methods for the isolation of circulating tumor cells (CTCs) or nucleic acids present in a standard clinical sample of only 5-10 mL of blood provide inadequate yields for early cancer detection and comprehensive molecular profiling. We have developed a flexible magnetic wire that can retrieve rare biomarkers from the subject's blood in vivo at a much higher yield. The wire is inserted and removed through a standard intravenous catheter and captures biomarkers that have been previously labeled with injected magnetic particles. In a proof-of-concept experiment in a live porcine model, we demonstrate the in vivo labeling and single-pass capture of viable model CTCs in less than 10 seconds. The wire achieves capture efficiencies that correspond to enrichments of 10-80 times the amount of CTCs in a 5-mL blood draw, and to 500-5,000 times the enrichments achieved by the commercially available Gilupi CellCollector.
View details for PubMedID 30524876
-
Marrying Nanomagnetics with RNA Sequencing of Single Cancer Cells
IEEE. 2018
View details for Web of Science ID 000455204800194
-
Thin-Film Magnetic Inductors for Gigahertz Integrated Applications
IEEE. 2018
View details for Web of Science ID 000455204800491
-
Validation of Plasma TIMP-1 to Identify Lung Cancer in Smokers
AMER THORACIC SOC. 2018
View details for Web of Science ID 000449980305162
-
A blood biomarker for monitoring response to anti-EGFR therapy
CANCER BIOMARKERS
2018; 22 (2): 333–44
View details for DOI 10.3233/CBM-171149
View details for Web of Science ID 000437251500016
-
Longitudinal Multiplexed Measurement of Quantitative Proteomic Signatures in Mouse Lymphoma Models Using Magneto-Nanosensors.
Theranostics
2018; 8 (5): 1389–98
Abstract
Cancer proteomics is the manifestation of relevant biological processes in cancer development. Thus, it reflects the activities of tumor cells, host-tumor interactions, and systemic responses to cancer therapy. To understand the causal effects of tumorigenesis or therapeutic intervention, longitudinal studies are greatly needed. However, most of the conventional mouse experiments are unlikely to accommodate frequent collection of serum samples with a large enough volume for multiple protein assays towards single-object analysis. Here, we present a technique based on magneto-nanosensors to longitudinally monitor the protein profiles in individual mice of lymphoma models using a small volume of a sample for multiplex assays.Methods:Drug-sensitive and -resistant cancer cell lines were used to develop the mouse models that render different outcomes upon the drug treatment. Two groups of mice were inoculated with each cell line, and treated with either cyclophosphamide or vehicle solution. Serum samples taken longitudinally from each mouse in the groups were measured with 6-plex magneto-nanosensor cytokine assays. To find the origin of IL-6, experiments were performed using IL-6 knock-out mice.Results:The differences in serum IL-6 and GCSF levels between the drug-treated and untreated groups were revealed by the magneto-nanosensor measurement on individual mice. Using the multiplex assays and mouse models, we found that IL-6 is secreted by the host in the presence of tumor cells upon the drug treatment.Conclusion:The multiplex magneto-nanosensor assays enable longitudinal proteomic studies on mouse tumor models to understand tumor development and therapy mechanisms more precisely within a single biological object.
View details for PubMedID 29507628
-
Gigahertz-Band Integrated Magnetic Inductors
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES
2017; 65 (12): 4893–4900
View details for DOI 10.1109/TMTT.2017.2728040
View details for Web of Science ID 000418391300013
-
Current Reconstruction of Bundle Conductors Based on Tunneling Magnetoresistive Sensors
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2017
View details for DOI 10.1109/TMAG.2017.2712699
View details for Web of Science ID 000413981300181
-
Simultaneous Profiling of DNA Mutation and Methylation by Melting Analysis Using Magnetoresistive Biosensor Array.
ACS nano
2017; 11 (9): 8864-8870
Abstract
Epigenetic modifications, in particular DNA methylation, are gaining increasing interest as complementary information to DNA mutations for cancer diagnostics and prognostics. We introduce a method to simultaneously profile DNA mutation and methylation events for an array of sites with single site specificity. Genomic (mutation) or bisulphite-treated (methylation) DNA is amplified using nondiscriminatory primers, and the amplicons are then hybridized to a giant magnetoresistive (GMR) biosensor array followed by melting curve measurements. The GMR biosensor platform offers scalable multiplexed detection of DNA hybridization, which is insensitive to temperature variation. The melting curve approach further enhances the assay specificity and tolerance to variations in probe length. We demonstrate the utility of this method by simultaneously profiling five mutation and four methylation sites in human melanoma cell lines. The method correctly identified all mutation and methylation events and further provided quantitative assessment of methylation density validated by bisulphite pyrosequencing.
View details for DOI 10.1021/acsnano.7b03053
View details for PubMedID 28832112
View details for PubMedCentralID PMC5810360
-
Novel Method for Magnetic Field Vector Measurement Based on Dual-Axial Tunneling Magnetoresistive Sensors
IEEE TRANSACTIONS ON MAGNETICS
2017; 53 (8)
View details for DOI 10.1109/TMAG.2017.2655007
View details for Web of Science ID 000408121900007
-
Denaturation strategies for detection of double stranded PCR products on GMR magnetic biosensor array
BIOSENSORS & BIOELECTRONICS
2017; 93: 155-160
Abstract
Microarrays and other surface-based nucleic acid detection schemes rely on the hybridization of the target to surface-bound detection probes. We present the first comparison of two strategies to detect DNA using a giant magnetoresistive (GMR) biosensor platform starting from an initially double-stranded DNA target. The target strand of interest is biotinylated and detected by the GMR sensor by linking streptavidin magnetic nanoparticles (MNPs) to the sensor surface. The sensor platform has a dynamic detection range from 40pM to 40nM with highly reproducible results and is used to monitor real-time binding signals. The first strategy, using off-chip heat denaturation followed by sequential on-chip incubation of the nucleic acids and MNPs, produces a signal that stabilizes quickly but the signal magnitude is reduced due to competitive rehybridization of the target in solution. The second strategy, using magnetic capture of the double-stranded product followed by denaturing, produces a higher signal but the signal increase is limited by diffusion of the MNPs. Our results show that both strategies give highly reproducible results but that the signal obtained using magnetic capture is higher and insensitive to rehybridization.
View details for DOI 10.1016/j.bios.2016.09.031
View details for Web of Science ID 000399259000022
-
Closed-loop model: An optimization of integrated thin-film magnetic devices
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS
2017; 432: 218-223
View details for DOI 10.1016/j.jmmm.2017.01.089
View details for Web of Science ID 000399601600031
-
Exchange-Biased Anisotropic Magnetoresistive Field Sensor
IEEE SENSORS JOURNAL
2017; 17 (11): 3309-3315
View details for DOI 10.1109/JSEN.2017.2695238
View details for Web of Science ID 000401083200011
-
Magnetic Nanoparticle-Based Upregulation of B-Cell Lymphoma 2 Enhances Bone Regeneration.
Stem cells translational medicine
2017; 6 (1): 151-160
Abstract
Clinical translation of cell-based strategies for tissue regeneration remains challenging because survival of implanted cells within hostile, hypoxic wound environments is uncertain. Overexpression of B-cell lymphoma 2 (Bcl-2) has been shown to inhibit apoptosis in implanted cells. The present study describes an "off the shelf" prefabricated scaffold integrated with magnetic nanoparticles (MNPs) used to upregulate Bcl-2 expression in implanted adipose-derived stromal cells for bone regeneration. Iron oxide cores were sequentially coated with branched polyethyleneimine, minicircle plasmid encoding green fluorescent protein and Bcl-2, and poly-β-amino ester. Through in vitro assays, increased osteogenic potential and biological resilience were demonstrated in the magnetofected group over control and nucleofected groups. Similarly, our in vivo calvarial defect study showed that magnetofection had an efficiency rate of 30%, which in turn resulted in significantly more healing compared with control group and nucleofected group. Our novel, prefabricated MNP-integrated scaffold allows for in situ postimplant temporospatial control of cell transfection to augment bone regeneration. Stem Cells Translational Medicine 2017;6:151-160.
View details for DOI 10.5966/sctm.2016-0051
View details for PubMedID 28170185
-
Multigene Profiling of Single Circulating Tumor Cells
Molecular & Cellular Oncology
2017; 4 (2): e1289295
Abstract
Numerous techniques for isolating circulating tumor cells (CTCs) have been developed. Concurrently, single-cell techniques that can reveal molecular components of CTCs have become widely available. We discuss how the combination of isolation and multigene profiling of single CTCs in our platform can facilitate eventual translation to the clinic.
View details for DOI 10.1080/23723556.2017.1289295
View details for PubMedCentralID PMC5383366
-
Capture and Genetic Analysis of Circulating Tumor Cells Using a Magnetic Separation Device (Magnetic Sifter)
CIRCULATING TUMOR CELLS: METHODS AND PROTOCOLS
2017; 1634: 153–62
View details for DOI 10.1007/978-1-4939-7144-2_12
View details for Web of Science ID 000449398600014
-
Hierarchical complexity and the size limits of life
Proceedings of the Royal Society B: Biological Sciences
2017; 284
Abstract
Over the past 3.8 billion years, the maximum size of life has increased by approximately 18 orders of magnitude. Much of this increase is associated with two major evolutionary innovations: the evolution of eukaryotes from prokaryotic cells approximately 1.9 billion years ago (Ga), and multicellular life diversifying from unicellular ancestors approximately 0.6 Ga. However, the quantitative relationship between organismal size and structural complexity remains poorly documented. We assessed this relationship using a comprehensive dataset that includes organismal size and level of biological complexity for 11 172 extant genera. We find that the distributions of sizes within complexity levels are unimodal, whereas the aggregate distribution is multimodal. Moreover, both the mean size and the range of size occupied increases with each additional level of complexity. Increases in size range are non-symmetric: the maximum organismal size increases more than the minimum. The majority of the observed increase in organismal size over the history of life on the Earth is accounted for by two discrete jumps in complexity rather than evolutionary trends within levels of complexity. Our results provide quantitative support for an evolutionary expansion away from a minimal size constraint and suggest a fundamental rescaling of the constraints on minimal and maximal size as biological complexity increases.
View details for DOI 10.1098/rspb.2017.1039
View details for PubMedCentralID PMC5489738
-
Capture and Genetic Analysis of Circulating Tumor Cells Using a Magnetic Separation Device (Magnetic Sifter).
Methods in molecular biology (Clifton, N.J.)
2017; 1634: 153–62
Abstract
Circulating tumor cells (CTCs) are currently widely studied for their potential application as part of a liquid biopsy. These cells are shed from the primary tumor into the circulation, and are postulated to provide insight into the molecular makeup of the actual tumor in a minimally invasive manner. However, they are extremely rare in blood, with typical concentrations of 1-100 in a milliliter of blood; hence, a need exists for a rapid and high-purity method for isolating CTCs from whole blood. Here, we describe the application of a microfabricated magnetic sifter toward isolation of CTCs from whole blood at volumetric flow rates of 10 mL/h, along with the use of a PDMS-based nanowell system for single-cell gene expression profiling. This method allows rapid isolation of CTCs and subsequent integration with downstream genetic profiling methods for clinical applications such as targeted therapy, therapy monitoring, or further biological studies.
View details for PubMedID 28819848
-
High-throughput full-length single-cell mRNA-seq of rare cells.
PloS one
2017; 12 (11): e0188510
Abstract
Single-cell characterization techniques, such as mRNA-seq, have been applied to a diverse range of applications in cancer biology, yielding great insight into mechanisms leading to therapy resistance and tumor clonality. While single-cell techniques can yield a wealth of information, a common bottleneck is the lack of throughput, with many current processing methods being limited to the analysis of small volumes of single cell suspensions with cell densities on the order of 107 per mL. In this work, we present a high-throughput full-length mRNA-seq protocol incorporating a magnetic sifter and magnetic nanoparticle-antibody conjugates for rare cell enrichment, and Smart-seq2 chemistry for sequencing. We evaluate the efficiency and quality of this protocol with a simulated circulating tumor cell system, whereby non-small-cell lung cancer cell lines (NCI-H1650 and NCI-H1975) are spiked into whole blood, before being enriched for single-cell mRNA-seq by EpCAM-functionalized magnetic nanoparticles and the magnetic sifter. We obtain high efficiency (> 90%) capture and release of these simulated rare cells via the magnetic sifter, with reproducible transcriptome data. In addition, while mRNA-seq data is typically only used for gene expression analysis of transcriptomic data, we demonstrate the use of full-length mRNA-seq chemistries like Smart-seq2 to facilitate variant analysis of expressed genes. This enables the use of mRNA-seq data for differentiating cells in a heterogeneous population by both their phenotypic and variant profile. In a simulated heterogeneous mixture of circulating tumor cells in whole blood, we utilize this high-throughput protocol to differentiate these heterogeneous cells by both their phenotype (lung cancer versus white blood cells), and mutational profile (H1650 versus H1975 cells), in a single sequencing run. This high-throughput method can help facilitate single-cell analysis of rare cell populations, such as circulating tumor or endothelial cells, with demonstrably high-quality transcriptomic data.
View details for PubMedID 29186152
View details for PubMedCentralID PMC5706670
-
Multilayer anisotropic magnetoresistive angle sensor
Sensors and Actuators A: Physical
2017; 263: 159-165
View details for DOI 10.1016/j.sna.2017.06.001
-
A Novel High-Performance Energy Harvester Based on Nonlinear Resonance for Scavenging Power-Frequency Magnetic Energy
IEEE Transactions on Industrial Electronics
2017; 64 (8): 6556-6564
View details for DOI 10.1109/TIE.2017.2682040
-
Stand-Alone Stretchable Absolute Pressure Sensing System for Industrial Applications
IEEE Transactions on Industrial Electronics
2017; 64 (11): 8739-8746
View details for DOI 10.1109/TIE.2017.2701763
-
Electrically Tunable Integrated Thin‐Film Magnetoelectric Resonators
Advanced Materials Technologies
2017; 2 (8)
View details for DOI 10.1002/admt.201700062
-
Simultaneous Profiling of DNA Mutation and Methylation by Melting Analysis Using Magnetoresistive Biosensor Array
ACS Nano
2017; 11 (9): 8864–8870
Abstract
Epigenetic modifications, in particular DNA methylation, are gaining increasing interest as complementary information to DNA mutations for cancer diagnostics and prognostics. We introduce a method to simultaneously profile DNA mutation and methylation events for an array of sites with single site specificity. Genomic (mutation) or bisulphite-treated (methylation) DNA is amplified using nondiscriminatory primers, and the amplicons are then hybridized to a giant magnetoresistive (GMR) biosensor array followed by melting curve measurements. The GMR biosensor platform offers scalable multiplexed detection of DNA hybridization, which is insensitive to temperature variation. The melting curve approach further enhances the assay specificity and tolerance to variations in probe length. We demonstrate the utility of this method by simultaneously profiling five mutation and four methylation sites in human melanoma cell lines. The method correctly identified all mutation and methylation events and further provided quantitative assessment of methylation density validated by bisulphite pyrosequencing.
View details for DOI 10.1021/acsnano.7b03053
View details for PubMedCentralID PMC5810360
-
Multigene profiling of single circulating tumor cells.
Molecular & cellular oncology
2017; 4 (2)
Abstract
Numerous techniques for isolating circulating tumor cells (CTCs) have been developed. Concurrently, single-cell techniques that can reveal molecular components of CTCs have become widely available. We discuss how the combination of isolation and multigene profiling of single CTCs in our platform can facilitate eventual translation to the clinic.
View details for DOI 10.1080/23723556.2017.1289295
View details for PubMedID 28401190
View details for PubMedCentralID PMC5383366
-
Longitudinal Monitoring of Antibody Responses against Tumor Cells Using Magneto-nanosensors with a Nanoliter of Blood.
Nano letters
2017; 17 (11): 6644–52
Abstract
Each immunoglobulin isotype has unique immune effector functions. The contribution of these functions in the elimination of pathogens and tumors can be determined by monitoring quantitative temporal changes in isotype levels. Here, we developed a novel technique using magneto-nanosensors based on the effect of giant magnetoresistance (GMR) for longitudinal monitoring of total and antigen-specific isotype levels with high precision, using as little as 1 nL of serum. Combining in vitro serologic measurements with in vivo imaging techniques, we investigated the role of the antibody response in the regression of firefly luciferase (FL)-labeled lymphoma cells in spleen, kidney, and lymph nodes in a syngeneic Burkitt's lymphoma mouse model. Regression status was determined by whole body bioluminescent imaging (BLI). The magneto-nanosensors revealed that anti-FL IgG2a and total IgG2a were elevated and sustained in regression mice compared to non-regression mice (p < 0.05). This platform shows promise for monitoring immunotherapy, vaccination, and autoimmunity.
View details for PubMedID 28990786
-
Molecular profiling of single circulating tumor cells from lung cancer patients
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA
2016; 113 (52): E8379-E8386
Abstract
Circulating tumor cells (CTCs) are established cancer biomarkers for the "liquid biopsy" of tumors. Molecular analysis of single CTCs, which recapitulate primary and metastatic tumor biology, remains challenging because current platforms have limited throughput, are expensive, and are not easily translatable to the clinic. Here, we report a massively parallel, multigene-profiling nanoplatform to compartmentalize and analyze hundreds of single CTCs. After high-efficiency magnetic collection of CTC from blood, a single-cell nanowell array performs CTC mutation profiling using modular gene panels. Using this approach, we demonstrated multigene expression profiling of individual CTCs from non-small-cell lung cancer (NSCLC) patients with remarkable sensitivity. Thus, we report a high-throughput, multiplexed strategy for single-cell mutation profiling of individual lung cancer CTCs toward minimally invasive cancer therapy prediction and disease monitoring.
View details for DOI 10.1073/pnas.1608461113
View details for PubMedID 27956614
-
High-Resolution Analysis of Antibodies to Post-Translational Modifications Using Peptide Nanosensor Microarrays
ACS NANO
2016; 10 (12): 10652-10660
Abstract
Autoantibodies are a hallmark of autoimmune diseases such as lupus and have the potential to be used as biomarkers for diverse diseases, including immunodeficiency, infectious disease, and cancer. More precise detection of antibodies to specific targets is needed to improve diagnosis of such diseases. Here, we report the development of reusable peptide microarrays, based on giant magnetoresistive (GMR) nanosensors optimized for sensitively detecting magnetic nanoparticle labels, for the detection of antibodies with a resolution of a single post-translationally modified amino acid. We have also developed a chemical regeneration scheme to perform multiplex assays with a high level of reproducibility, resulting in greatly reduced experimental costs. In addition, we show that peptides synthesized directly on the nanosensors are approximately two times more sensitive than directly spotted peptides. Reusable peptide nanosensor microarrays enable precise detection of autoantibodies with high resolution and sensitivity and show promise for investigating antibody-mediated immune responses to autoantigens, vaccines, and pathogen-derived antigens as well as other fundamental peptide-protein interactions.
View details for DOI 10.1021/acsnano.6b03786
View details for PubMedID 27636738
-
Portable, one-step, and rapid GMR biosensor platform with smartphone interface.
Biosensors & bioelectronics
2016; 85: 1-7
Abstract
Quantitative immunoassay tests in clinical laboratories require trained technicians, take hours to complete with multiple steps, and the instruments used are generally immobile-patient samples have to be sent in to the labs for analysis. This prevents quantitative immunoassay tests to be performed outside laboratory settings. A portable, quantitative immunoassay device will be valuable in rural and resource-limited areas, where access to healthcare is scarce or far away. We have invented Eigen Diagnosis Platform (EDP), a portable quantitative immunoassay platform based on Giant Magnetoresistance (GMR) biosensor technology. The platform does not require a trained technician to operate, and only requires one-step user involvement. It displays quantitative results in less than 15min after sample insertion, and each test costs less than US$4. The GMR biosensor employed in EDP is capable of detecting multiple biomarkers in one test, enabling a wide array of immune diagnostics to be performed simultaneously. In this paper, we describe the design of EDP, and demonstrate its capability. Multiplexed assay of human immunoglobulin G and M (IgG and IgM) antibodies with EDP achieves sensitivities down to 0.07 and 0.33 nanomolar, respectively. The platform will allow lab testing to be performed in remote areas, and open up applications of immunoassay testing in other non-clinical settings, such as home, school, and office.
View details for DOI 10.1016/j.bios.2016.04.046
View details for PubMedID 27148826
-
Denaturation strategies for detection of double stranded PCR products on GMR magnetic biosensor array.
Biosensors & bioelectronics
2016
Abstract
Microarrays and other surface-based nucleic acid detection schemes rely on the hybridization of the target to surface-bound detection probes. We present the first comparison of two strategies to detect DNA using a giant magnetoresistive (GMR) biosensor platform starting from an initially double-stranded DNA target. The target strand of interest is biotinylated and detected by the GMR sensor by linking streptavidin magnetic nanoparticles (MNPs) to the sensor surface. The sensor platform has a dynamic detection range from 40pM to 40nM with highly reproducible results and is used to monitor real-time binding signals. The first strategy, using off-chip heat denaturation followed by sequential on-chip incubation of the nucleic acids and MNPs, produces a signal that stabilizes quickly but the signal magnitude is reduced due to competitive rehybridization of the target in solution. The second strategy, using magnetic capture of the double-stranded product followed by denaturing, produces a higher signal but the signal increase is limited by diffusion of the MNPs. Our results show that both strategies give highly reproducible results but that the signal obtained using magnetic capture is higher and insensitive to rehybridization.
View details for DOI 10.1016/j.bios.2016.09.031
View details for PubMedID 27650710
-
Small Molecule Detection in Saliva Facilitates Portable Tests of Marijuana Abuse.
Analytical chemistry
2016; 88 (15): 7457-7461
Abstract
As medical and recreational use of cannabis, or marijuana, becomes more prevalent, law enforcement needs a tool to evaluate whether drivers are operating vehicles under the influence of cannabis, specifically the psychoactive substance, tetrahydrocannabinol (THC). However, the cutoff concentration of THC that causes impairment is still controversial, and current on-site screening tools are not sensitive enough to detect trace amounts of THC in oral fluids. Here we present a novel sensing platform that employs giant magnetoresistive (GMR) biosensors integrated with a portable reader system and smartphone to detect THC in saliva using competitive assays. With a simple saliva collection scheme, we have optimized the assay to measure THC in the range from 0 to 50 ng/mL, covering most cutoff values proposed in previous studies. This work facilitates on-site screening for THC and shows potential for testing of other small molecule drugs and analytes in point-of-care (POC) settings.
View details for DOI 10.1021/acs.analchem.6b01688
View details for PubMedID 27434697
-
Effect of Mg Oxidation Degree on Rashba-Effect-Induced Torques in Ta/CoFeB/Mg(MgO) Multilayer
IEEE TRANSACTIONS ON MAGNETICS
2016; 52 (7)
View details for DOI 10.1109/TMAG.2016.2515025
View details for Web of Science ID 000379924800013
-
Tunneling Magnetoresistive Sensors for High-Frequency Corona Discharge Location
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2016
View details for DOI 10.1109/TMAG.2016.2527926
View details for Web of Science ID 000379924800096
-
A Novel Magnetic Energy Harvester Using Spinning Magnetoelectric Transducer
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2016
View details for DOI 10.1109/TMAG.2016.2540656
View details for Web of Science ID 000379924800234
-
Giant magnetoresistive sensor array for sensitive and specific multiplexed food allergen detection
BIOSENSORS & BIOELECTRONICS
2016; 80: 359-365
Abstract
Current common allergen detection methods, including enzyme-linked immunosorbent assays (ELISAs) and dip-stick methods, do not provide adequate levels of sensitivity and specificity for at-risk allergic patients. A method for performing highly sensitive and specific detection of multiple food allergens is thus imperative as food allergies are becoming increasingly recognized as a major healthcare concern, affecting an estimated 4% of the total population. We demonstrate first instance of sensitive and specific multiplexed detection of major peanut allergens Ara h 1 and Ara h 2, and wheat allergen Gliadin using giant magnetoresistive (GMR) sensor arrays. Commercialized ELISA kits for Ara h 1 and Ara h 2 report limits of detection (LODs) at 31.5 ng/mL and 0.2 ng/mL, respectively. In addition, the 96-well-based ELISA developed in-house for Gliadin was found to have a LOD of 40 ng/mL. Our multiplexed GMR-based assay demonstrates the ability to perform all three assays on the same chip specifically and with sensitivities at LODs about an order of magnitude lower than those of 96-well-based ELISAs. LODs of GMR-based assays developed for Ara h 1, Ara h 2, and Gliadin were 7.0 ng/mL, 0.2 ng/mL, and 1.5 ng/mL, respectively, with little to no cross-reactivity. These LODs are clinically important as some patients could react strongly against such low allergen levels. Given the limitations of current industrial detection technology, multiplexed GMR-based assays provide a method for highly sensitive and specific simultaneous detection of any combination of food-product allergens, thus protecting allergic patients from life-threatening events, including anaphylaxis, by unintentional consumption.
View details for DOI 10.1016/j.bios.2016.02.002
View details for Web of Science ID 000372558500051
-
Giant magnetoresistive sensor array for sensitive and specific multiplexed food allergen detection.
Biosensors & bioelectronics
2016; 80: 359-365
Abstract
Current common allergen detection methods, including enzyme-linked immunosorbent assays (ELISAs) and dip-stick methods, do not provide adequate levels of sensitivity and specificity for at-risk allergic patients. A method for performing highly sensitive and specific detection of multiple food allergens is thus imperative as food allergies are becoming increasingly recognized as a major healthcare concern, affecting an estimated 4% of the total population. We demonstrate first instance of sensitive and specific multiplexed detection of major peanut allergens Ara h 1 and Ara h 2, and wheat allergen Gliadin using giant magnetoresistive (GMR) sensor arrays. Commercialized ELISA kits for Ara h 1 and Ara h 2 report limits of detection (LODs) at 31.5 ng/mL and 0.2 ng/mL, respectively. In addition, the 96-well-based ELISA developed in-house for Gliadin was found to have a LOD of 40 ng/mL. Our multiplexed GMR-based assay demonstrates the ability to perform all three assays on the same chip specifically and with sensitivities at LODs about an order of magnitude lower than those of 96-well-based ELISAs. LODs of GMR-based assays developed for Ara h 1, Ara h 2, and Gliadin were 7.0 ng/mL, 0.2 ng/mL, and 1.5 ng/mL, respectively, with little to no cross-reactivity. These LODs are clinically important as some patients could react strongly against such low allergen levels. Given the limitations of current industrial detection technology, multiplexed GMR-based assays provide a method for highly sensitive and specific simultaneous detection of any combination of food-product allergens, thus protecting allergic patients from life-threatening events, including anaphylaxis, by unintentional consumption.
View details for DOI 10.1016/j.bios.2016.02.002
View details for PubMedID 26859787
-
Multiplex giant magnetoresistive biosensor microarrays identify interferon-associated autoantibodies in systemic lupus erythematosus
SCIENTIFIC REPORTS
2016; 6
Abstract
High titer, class-switched autoantibodies are a hallmark of systemic lupus erythematosus (SLE). Dysregulation of the interferon (IFN) pathway is observed in individuals with active SLE, although the association of specific autoantibodies with chemokine score, a combined measurement of three IFN-regulated chemokines, is not known. To identify autoantibodies associated with chemokine score, we developed giant magnetoresistive (GMR) biosensor microarrays, which allow the parallel measurement of multiple serum antibodies to autoantigens and peptides. We used the microarrays to analyze serum samples from SLE patients and found individuals with high chemokine scores had significantly greater reactivity to 13 autoantigens than individuals with low chemokine scores. Our findings demonstrate that multiple autoantibodies, including antibodies to U1-70K and modified histone H2B tails, are associated with IFN dysregulation in SLE. Further, they show the microarrays are capable of identifying autoantibodies associated with relevant clinical manifestations of SLE, with potential for use as biomarkers in clinical practice.
View details for DOI 10.1038/srep27623
View details for Web of Science ID 000377358700002
View details for PubMedID 27279139
-
Effect of annealing on exchange stiffness of ultrathin CoFeB film with perpendicular magnetic anisotropy
APPLIED PHYSICS LETTERS
2016; 108 (15)
View details for DOI 10.1063/1.4945039
View details for Web of Science ID 000374314000032
-
Experimental and theoretical investigation of the precise transduction mechanism in giant magnetoresistive biosensors
SCIENTIFIC REPORTS
2016; 6
Abstract
Giant magnetoresistive (GMR) biosensors consisting of many rectangular stripes are being developed for high sensitivity medical diagnostics of diseases at early stages, but many aspects of the sensing mechanism remain to be clarified. Using e-beam patterned masks on the sensors, we showed that the magnetic nanoparticles with a diameter of 50 nm located between the stripes predominantly determine the sensor signals over those located on the sensor stripes. Based on computational analysis, it was confirmed that the particles in the trench, particularly those near the edges of the stripes, mainly affect the sensor signals due to additional field from the stripe under an applied field. We also demonstrated that the direction of the average magnetic field from the particles that contributes to the signal is indeed the same as that of the applied field, indicating that the particles in the trench are pivotal to produce sensor signal. Importantly, the same detection principle was validated with a duplex protein assay. Also, 8 different types of sensor stripes were fabricated and design parameters were explored. According to the detection principle uncovered, GMR biosensors can be further optimized to improve their sensitivity, which is highly desirable for early diagnosis of diseases.
View details for DOI 10.1038/srep18692
View details for Web of Science ID 000368275200001
View details for PubMedCentralID PMC4700494
-
Experimental and theoretical investigation of the precise transduction mechanism in giant magnetoresistive biosensors.
Scientific reports
2016; 6: 18692
Abstract
Giant magnetoresistive (GMR) biosensors consisting of many rectangular stripes are being developed for high sensitivity medical diagnostics of diseases at early stages, but many aspects of the sensing mechanism remain to be clarified. Using e-beam patterned masks on the sensors, we showed that the magnetic nanoparticles with a diameter of 50 nm located between the stripes predominantly determine the sensor signals over those located on the sensor stripes. Based on computational analysis, it was confirmed that the particles in the trench, particularly those near the edges of the stripes, mainly affect the sensor signals due to additional field from the stripe under an applied field. We also demonstrated that the direction of the average magnetic field from the particles that contributes to the signal is indeed the same as that of the applied field, indicating that the particles in the trench are pivotal to produce sensor signal. Importantly, the same detection principle was validated with a duplex protein assay. Also, 8 different types of sensor stripes were fabricated and design parameters were explored. According to the detection principle uncovered, GMR biosensors can be further optimized to improve their sensitivity, which is highly desirable for early diagnosis of diseases.
View details for DOI 10.1038/srep18692
View details for PubMedID 26728870
View details for PubMedCentralID PMC4700494
-
Bio-Inspired Stretchable Absolute Pressure Sensor Network.
Sensors
2016; 16 (1)
Abstract
A bio-inspired absolute pressure sensor network has been developed. Absolute pressure sensors, distributed on multiple silicon islands, are connected as a network by stretchable polyimide wires. This sensor network, made on a 4'' wafer, has 77 nodes and can be mounted on various curved surfaces to cover an area up to 0.64 m × 0.64 m, which is 100 times larger than its original size. Due to Micro Electro-Mechanical system (MEMS) surface micromachining technology, ultrathin sensing nodes can be realized with thicknesses of less than 100 µm. Additionally, good linearity and high sensitivity (~14 mV/V/bar) have been achieved. Since the MEMS sensor process has also been well integrated with a flexible polymer substrate process, the entire sensor network can be fabricated in a time-efficient and cost-effective manner. Moreover, an accurate pressure contour can be obtained from the sensor network. Therefore, this absolute pressure sensor network holds significant promise for smart vehicle applications, especially for unmanned aerial vehicles.
View details for DOI 10.3390/s16010055
View details for PubMedID 26729134
View details for PubMedCentralID PMC4732088
-
Linear Control of Magneto-Electric Effect With Small Electric Fields
IEEE MAGNETICS LETTERS
2016; 7
View details for DOI 10.1109/LMAG.2016.2551694
View details for Web of Science ID 000399976300001
-
Magneto-nanosensor platform for probing low-affinity protein-protein interactions and identification of a low-affinity PD-L1/PD-L2 interaction.
Nature communications
2016; 7: 12220-?
Abstract
Substantial efforts have been made to understand the interactions between immune checkpoint receptors and their ligands targeted in immunotherapies against cancer. To carefully characterize the complete network of interactions involved and the binding affinities between their extracellular domains, an improved kinetic assay is needed to overcome limitations with surface plasmon resonance (SPR). Here, we present a magneto-nanosensor platform integrated with a microfluidic chip that allows measurement of dissociation constants in the micromolar-range. High-density conjugation of magnetic nanoparticles with prey proteins allows multivalent receptor interactions with sensor-immobilized bait proteins, more closely mimicking natural-receptor clustering on cells. The platform has advantages over traditional SPR in terms of insensitivity of signal responses to pH and salinity, less consumption of proteins and better sensitivities. Using this platform, we characterized the binding affinities of the PD-1-PD-L1/PD-L2 co-inhibitory receptor system, and discovered an unexpected interaction between the two known PD-1 ligands, PD-L1 and PD-L2.
View details for DOI 10.1038/ncomms12220
View details for PubMedID 27447090
-
Microfluidic multiplexed partitioning enables flexible and effective utilization of magnetic sensor arrays.
Lab on a chip
2015; 15 (22): 4273-4276
Abstract
We demonstrate microfluidic partitioning of a giant magnetoresistive sensor array into individually addressable compartments that enhances its effective use. Using different samples and reagents in each compartment enables measuring of cross-reactive species and wide dynamic ranges on a single chip. This compartmentalization technique motivates the employment of high density sensor arrays for highly parallelized measurements in lab-on-a-chip devices.
View details for DOI 10.1039/c5lc00953g
View details for PubMedID 26395039
-
Achieving Isotropic Permeability for Integrated Inductors
IEEE TRANSACTIONS ON MAGNETICS
2015; 51 (11)
View details for DOI 10.1109/TMAG.2015.2441091
View details for Web of Science ID 000364770500227
-
Contactless Current Sensors Based on Magnetic Tunnel Junction for Smart Grid Applications
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2015
View details for DOI 10.1109/TMAG.2015.2446332
View details for Web of Science ID 000364770500322
-
Prediction and Optimization of Linearity of MTJ Magnetic Sensors Based on Single-Domain Model
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2015
View details for DOI 10.1109/TMAG.2015.2439152
View details for Web of Science ID 000364770500315
-
45 degrees Induced Magnetic Anisotropy for Isotropic High-Frequency Permeability
IEEE TRANSACTIONS ON MAGNETICS
2015; 51 (11)
View details for DOI 10.1109/TMAG.2015.2440292
View details for Web of Science ID 000364770500225
-
Electric Field Sensor Based on Piezoelectric Bending Effect for Wide Range Measurement
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2015; 62 (9): 5730-5737
View details for DOI 10.1109/TIE.2015.2414397
View details for Web of Science ID 000359560800038
-
High-Density 2D Homo- and Hetero- Plasmonic Dimers with Universal Sub-10-nm Gaps
ACS NANO
2015; 9 (9): 9331-9339
Abstract
Fabrication of high-density plasmonic dimers on a large (wafer) scale is crucial for applications in surface-enhanced spectroscopy, bio- and molecular sensing, and optoelectronics. Here, we present an experimental approach based on nanoimprint lithography and shadow evaporation that allows for the fabrication of high-density, large-scale homo- (Au-Au and Ag-Ag) and hetero- (Au-Ag) dimer substrates with precise and consistent sub-10-nm gaps. We performed scanning electron, scanning transmission electron, and atomic force microscopy studies along with a complete electron energy-loss spectroscopy (EELS) characterization. We observed distinct plasmonic modes on these dimers, which are well interpreted by finite-difference time-domain (FDTD) and plasmon hybridization calculations.
View details for DOI 10.1021/acsnano.5b03090
View details for Web of Science ID 000361935800073
View details for PubMedID 26202803
-
Gene expression profiling of individual circulating tumor cells from non-small cell lung cancer (NSCLC) patients via integrated nanotechnologies
AMER ASSOC CANCER RESEARCH. 2015
View details for DOI 10.1158/1538-7445.AM2015-LB-280
View details for Web of Science ID 000371597100372
-
On the importance of sensor height variation for detection of magnetic labels by magnetoresistive sensors
SCIENTIFIC REPORTS
2015; 5: 12282
Abstract
Magnetoresistive sensors are widely used for biosensing by detecting the signal from magnetic labels bound to a functionalized area that usually covers the entire sensor structure. Magnetic labels magnetized by a homogeneous applied magnetic field weaken and strengthen the applied field when they are over and outside the sensor area, respectively, and the detailed origin of the sensor signal in experimental studies has not been clarified. We systematically analyze the signal from both a single sensor stripe and an array of sensor stripes as function of the geometrical parameters of the sensor stripes as well as the distribution of magnetic labels over the stripes. We show that the signal from sensor stripes with a uniform protective coating, contrary to conventional wisdom in the field, is usually dominated by the contribution from magnetic labels between the sensor stripes rather than by the labels on top of the sensor stripes because these are at a lower height. We therefore propose a shift of paradigm to maximize the signal due to magnetic labels between sensor stripes. Guidelines for this optimization are provided and illustrated for an experimental case from the literature.
View details for PubMedID 26195089
-
A Nonintrusive Power Supply Design for Self-Powered Sensor Networks in the Smart Grid by Scavenging Energy From AC Power Line
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2015; 62 (7): 4398-4407
View details for DOI 10.1109/TIE.2014.2383992
View details for Web of Science ID 000354945400041
-
Optimum direct current magnetic bias in ferromagnetic phase for improvement of magnetoelectric effect
APPLIED PHYSICS LETTERS
2015; 106 (26)
View details for DOI 10.1063/1.4923417
View details for Web of Science ID 000357693200031
-
Reduction of magnetic 1/f noise in miniature anisotropic magnetoresistive sensors
APPLIED PHYSICS LETTERS
2015; 106 (21)
View details for DOI 10.1063/1.4921764
View details for Web of Science ID 000355631400021
-
Increasing ferromagnetic resonance frequency using lamination and shape
JOURNAL OF APPLIED PHYSICS
2015; 117 (17)
View details for DOI 10.1063/1.4913509
View details for Web of Science ID 000354984100508
-
Great enhancement of energy harvesting properties of piezoelectric/magnet composites by the employment of magnetic concentrator
JOURNAL OF APPLIED PHYSICS
2015; 117 (17)
View details for DOI 10.1063/1.4906964
View details for Web of Science ID 000354984100005
-
Mobile ions generated by external direct current electric field influence direct current measurement of giant magnetoresistance current sensors
JOURNAL OF APPLIED PHYSICS
2015; 117 (17)
View details for DOI 10.1063/1.4907698
View details for Web of Science ID 000354984100008
-
Magnetoelectric effect in shear-mode Pb(Zr, Ti)O-3/NdFeB composite cantilever
APPLIED PHYSICS LETTERS
2015; 106 (18)
View details for DOI 10.1063/1.4919738
View details for Web of Science ID 000354259200032
-
Enhanced performance of magnetoelectric energy harvester based on compound magnetic coupling effect
JOURNAL OF APPLIED PHYSICS
2015; 117 (14)
View details for DOI 10.1063/1.4917214
View details for Web of Science ID 000352967400020
-
In-plane longitudinal converse magnetoelectric effect in laminated composites: Aiming at sensing wide range electric field
APPLIED PHYSICS LETTERS
2015; 106 (8)
View details for DOI 10.1063/1.4913619
View details for Web of Science ID 000350546600053
-
A novel cylindrical torsional magnetoelectric composite based on d(15) shear-mode response
JOURNAL OF PHYSICS D-APPLIED PHYSICS
2015; 48 (4)
View details for DOI 10.1088/0022-3727/48/4/045001
View details for Web of Science ID 000348300900001
-
Hysteretic Modeling of Output Characteristics of Giant Magnetoresistive Current Sensors
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
2015; 62 (1): 516-524
View details for DOI 10.1109/TIE.2014.2326989
View details for Web of Science ID 000346767400053
-
Pilot Application of Magnetic Nanoparticle-Based Biosensor for Necrotizing Enterocolitis.
Journal of proteomics & bioinformatics
2015
Abstract
Necrotizing Enterocolitis (NEC) is a major source of neonatal morbidity and mortality. There is an ongoing need for a sensitive diagnostic instrument to discriminate NEC from neonatal sepsis. We hypothesized that magnetic nanopartile-based biosensor analysis of gut injury-associated biomarkers would provide such an instrument.We designed a magnetic multiplexed biosensor platform, allowing the parallel plasma analysis of C-reactive protein (CRP), matrix metalloproteinase-7 (MMp7), and epithelial cell adhesion molecule (EpCAM). Neonatal subjects with sepsis (n=5) or NEC (n=10) were compared to control (n=5) subjects to perform a proof of concept pilot study for the diagnosis of NEC using our ultra-sensitive biosensor platform.Our multiplexed NEC magnetic nanoparticle-based biosensor platform was robust, ultrasensitive (Limit of detection LOD: CRP 0.6 pg/ml; MMp7 20 pg/ml; and EpCAM 20 pg/ml), and displayed no cross-reactivity among analyte reporting regents. To gauge the diagnostic performance, bootstrapping procedure (500 runs) was applied: MMp7 and EpCAM collectively differentiated infants with NEC from control infants with ROC AUC of 0.96, and infants with NEC from those with sepsis with ROC AUC of 1.00. The 3-marker panel comprising of EpCAM, MMp7 and CRP had a corresponding ROC AUC of 0.956 and 0.975, respectively.The exploration of the multiplexed nano-biosensor platform shows promise to deliver an ultrasensitive instrument for the diagnosis of NEC in the clinical setting.
View details for PubMedID 26798207
-
Microfluidic multiplexed partitioning enables flexible and effective utilization of magnetic sensor arrays
LAB ON A CHIP
2015; 15 (22): 4273-4276
Abstract
We demonstrate microfluidic partitioning of a giant magnetoresistive sensor array into individually addressable compartments that enhances its effective use. Using different samples and reagents in each compartment enables measuring of cross-reactive species and wide dynamic ranges on a single chip. This compartmentalization technique motivates the employment of high density sensor arrays for highly parallelized measurements in lab-on-a-chip devices.
View details for DOI 10.1039/c5lc00953g
View details for Web of Science ID 000364072300003
View details for PubMedID 26395039
-
High performance wash-free magnetic bioassays through microfluidically enhanced particle specificity.
Scientific reports
2015; 5: 11693-?
Abstract
Magnetic biosensors have emerged as a sensitive and versatile platform for high performance medical diagnostics. These magnetic biosensors require well-tailored magnetic particles as detection probes, which need to give rise to a large and specific biological signal while showing very low nonspecific binding. This is especially important in wash-free bioassay protocols, which do not require removal of particles before measurement, often a necessity in point of care diagnostics. Here we show that magnetic interactions between magnetic particles and magnetized sensors dramatically impact particle transport and magnetic adhesion to the sensor surfaces. We investigate the dynamics of magnetic particles' biomolecular binding and magnetic adhesion to the sensor surface using microfluidic experiments. We elucidate how flow forces can inhibit magnetic adhesion, greatly diminishing or even eliminating nonspecific signals in wash-free magnetic bioassays, and enhancing signal to noise ratios by several orders of magnitude. Our method is useful for selecting and optimizing magnetic particles for a wide range of magnetic sensor platforms.
View details for DOI 10.1038/srep11693
View details for PubMedID 26123868
-
Modeling the Frequency Dependence of Packaged Linear Magnetoresisitive Sensors Based on MTJ
IEEE TRANSACTIONS ON MAGNETICS
2014; 50 (11)
View details for DOI 10.1109/TMAG.2014.2331369
View details for Web of Science ID 000349465900256
-
Spin-wave resonances in the presence of a Bloch wall
PHYSICAL REVIEW B
2014; 89 (22)
View details for DOI 10.1103/PhysRevB.89.224406
View details for Web of Science ID 000338016900002
-
Magnetic energy harvesting properties of piezofiber bimorph/NdFeB composites
APPLIED PHYSICS LETTERS
2014; 104 (9)
View details for DOI 10.1063/1.4867889
View details for Web of Science ID 000332729200115
-
Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips
LAB ON A CHIP
2014; 14 (1): 78-88
View details for DOI 10.1039/c3lc50580d
View details for Web of Science ID 000327669000008
-
Pilot Application of Magnetic Nanoparticle-Based Biosensor for Necrotizing Enterocolitis
Journal of Proteomics and Bioinformatics
2014
View details for DOI 10.4172/jpb.S5-002
-
Wafer-Scale Synthesis of Monodisperse Synthetic Magnetic Multilayer Nanorods
NANO LETTERS
2014; 14 (1): 333-338
Abstract
A double exposure technique has been used to fabricate nanoimprint stamps for making monodisperse nanorods with controllable lengths. The nanorod length is defined by a normal photolithography projection process whereas the nanorod width is defined by an edge-lithography process using a soft polydimethylsiloxane (PDMS) contact mask. Taking advantage of edge-lithography, the nanorod width can be less than the diffraction limit of the exposure light. Using these nanorod stamps, synthetic magnetic multilayer (SMM) nanorods have been fabricated using nanoimprint lithography, resulting in a length variation of ∼3%. Nanorod magnetic properties have been characterized in both longitudinal and in-plane transverse directions of the nanorods. A theoretical model has been established to explain the magnetic responses and has revealed that both shape anisotropy and interlayer interactions are important in determining the properties of SMM nanorods.
View details for DOI 10.1021/nl404089t
View details for Web of Science ID 000329586700053
View details for PubMedID 24329003
View details for PubMedCentralID PMC3931460
-
Isolation and mutational analysis of circulating tumor cells from lung cancer patients with magnetic sifters and biochips.
Lab on a chip
2013; 14 (1): 78-88
Abstract
Detection and characterization of circulating tumor cells (CTCs) may reveal insights into the diagnosis and treatment of malignant disease. Technologies for isolating CTCs developed thus far suffer from one or more limitations, such as low throughput, inability to release captured cells, and reliance on expensive instrumentation for enrichment or subsequent characterization. We report a continuing development of a magnetic separation device, the magnetic sifter, which is a miniature microfluidic chip with a dense array of magnetic pores. It offers high efficiency capture of tumor cells, labeled with magnetic nanoparticles, from whole blood with high throughput and efficient release of captured cells. For subsequent characterization of CTCs, an assay, using a protein chip with giant magnetoresistive nanosensors, has been implemented for mutational analysis of CTCs enriched with the magnetic sifter. The use of these magnetic technologies, which are separate devices, may lead the way to routine preparation and characterization of "liquid biopsies" from cancer patients.
View details for DOI 10.1039/c3lc50580d
View details for PubMedID 23969419
-
Functionalization of high-moment magnetic nanodisks for cell manipulation and separation
NANO RESEARCH
2013; 6 (10): 745-751
View details for DOI 10.1007/s12274-013-0352-4
View details for Web of Science ID 000325819000006
-
Monte Carlo simulation on magnetic nanoscavenger-based water disinfection system
AMER CHEMICAL SOC. 2013
View details for Web of Science ID 000329618403685
-
Modeling and experiments of magneto-nanosensors for diagnostics of radiation exposure and cancer.
Biomedical microdevices
2013; 15 (4): 665-671
Abstract
We present a resistive network model, protein assay data, and outlook of the giant magnetoresistive (GMR) spin-valve magneto-nanosensor platform ideal for multiplexed detection of protein biomarkers in solutions. The magneto-nanosensors are designed to have optimal performance considering several factors such as sensor dimension, shape anisotropy, and magnetic nanoparticle tags. The resistive network model indicates that thinner spin-valve sensors with narrower width lead to higher signals from magnetic nanoparticle tags. Standard curves and real-time measurements showed a sensitivity of ~10 pM for phosphorylated-structural maintenance of chromosome 1 (phosphor-SMC1), ~53 fM for granulocyte colony stimulation factor (GCSF), and ~460 fM for interleukin-6 (IL6), which are among the representative biomarkers for radiation exposure and cancer.
View details for DOI 10.1007/s10544-012-9678-z
View details for PubMedID 22763391
View details for PubMedCentralID PMC3674217
-
Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation
SCIENTIFIC REPORTS
2013; 3
Abstract
Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations showed excellent dose discrimination at ≥ 1 Gy in the time window of 1 to 7 days after exposure except 1 Gy at day 7. Saa1 dose response was limited to the first two days after exposure. A multiplex assay with both proteins showed improved dose classification accuracy. Our magneto-nanosensor assay demonstrates the dose and time responses, low-dose sensitivity, small volume requirements, and rapid speed that have important advantages in radiation triage biodosimetry.
View details for DOI 10.1038/srep02234
View details for Web of Science ID 000322001200002
View details for PubMedID 23868657
View details for PubMedCentralID PMC3715761
-
Integrated Transformers With Sputtered Laminated Magnetic Core
IEEE TRANSACTIONS ON MAGNETICS
2013; 49 (7): 4021-4027
View details for DOI 10.1109/TMAG.2013.2242865
View details for Web of Science ID 000322483200241
-
Rapid Characterization of Magnetic Moment of Cells for Magnetic Separation.
IEEE transactions on magnetics
2013; 49 (7): 3434-3437
Abstract
NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen were previously shown to be captured at high efficiencies by a microfabricated magnetic sifter. If fine control and optimization of the magnetic separation process is to be achieved, it is vital to be able to characterize the labeled cells' magnetic moment rapidly. We have thus adapted a rapid prototyping method to obtain the saturation magnetic moment of these cells. This method utilizes a cross-correlation algorithm to analyze the cells' motion in a simple fluidic channel to obtain their magnetophoretic velocity, and is effective even when the magnetic moments of cells are small. This rapid characterization is proven useful in optimizing our microfabricated magnetic sifter procedures for magnetic cell capture.
View details for DOI 10.1109/TMAG.2013.2245310
View details for PubMedID 24771946
View details for PubMedCentralID PMC3996843
-
Kerr-Imaged Edge-Curling Wall Effects of Narrow Magnetic Cores
IEEE TRANSACTIONS ON MAGNETICS
2013; 49 (7): 4017-4020
View details for DOI 10.1109/TMAG.2013.2237759
View details for Web of Science ID 000322483200240
-
Rapid Characterization of Magnetic Moment of Cells for Magnetic Separation
IEEE TRANSACTIONS ON MAGNETICS
2013; 49 (7): 3434-3437
Abstract
NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen were previously shown to be captured at high efficiencies by a microfabricated magnetic sifter. If fine control and optimization of the magnetic separation process is to be achieved, it is vital to be able to characterize the labeled cells' magnetic moment rapidly. We have thus adapted a rapid prototyping method to obtain the saturation magnetic moment of these cells. This method utilizes a cross-correlation algorithm to analyze the cells' motion in a simple fluidic channel to obtain their magnetophoretic velocity, and is effective even when the magnetic moments of cells are small. This rapid characterization is proven useful in optimizing our microfabricated magnetic sifter procedures for magnetic cell capture.
View details for DOI 10.1109/TMAG.2013.2245310
View details for Web of Science ID 000322483200092
View details for PubMedCentralID PMC3996843
-
A 256 Pixel Magnetoresistive Biosensor Microarray in 0.18 mu m CMOS
IEEE Radio Frequency Integrated Circuits (RFIC) Symposium in Conjunction with the IEEE MTT-S International Microwave Symposium (IMS) / Microwave Week
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2013: 1290–1301
Abstract
Magnetic nanotechnologies have shown significant potential in several areas of nanomedicine such as imaging, therapeutics, and early disease detection. Giant magnetoresistive spin-valve (GMR SV) sensors coupled with magnetic nanotags (MNTs) possess great promise as ultra-sensitive biosensors for diagnostics. We report an integrated sensor interface for an array of 256 GMR SV biosensors designed in 0.18 μm CMOS. Arranged like an imager, each of the 16 column level readout channels contains an analog front- end and a compact ΣΔ modulator (0.054 mm2) with 84 dB of dynamic range and an input referred noise of 49 nT/√Hz. Performance is demonstrated through detection of an ovarian cancer biomarker, secretory leukocyte peptidase inhibitor (SLPI), spiked at concentrations as low as 10 fM. This system is designed as a replacement for optical protein microarrays while also providing real-time kinetics monitoring.
View details for DOI 10.1109/JSSC.2013.2245058
View details for Web of Science ID 000320936300016
View details for PubMedCentralID PMC3993911
-
A 256 pixel magnetoresistive biosensor microarray in 0.18μm CMOS.
IEEE journal of solid-state circuits
2013; 48 (5): 1290-1301
Abstract
Magnetic nanotechnologies have shown significant potential in several areas of nanomedicine such as imaging, therapeutics, and early disease detection. Giant magnetoresistive spin-valve (GMR SV) sensors coupled with magnetic nanotags (MNTs) possess great promise as ultra-sensitive biosensors for diagnostics. We report an integrated sensor interface for an array of 256 GMR SV biosensors designed in 0.18 μm CMOS. Arranged like an imager, each of the 16 column level readout channels contains an analog front- end and a compact ΣΔ modulator (0.054 mm2) with 84 dB of dynamic range and an input referred noise of 49 nT/√Hz. Performance is demonstrated through detection of an ovarian cancer biomarker, secretory leukocyte peptidase inhibitor (SLPI), spiked at concentrations as low as 10 fM. This system is designed as a replacement for optical protein microarrays while also providing real-time kinetics monitoring.
View details for DOI 10.1109/JSSC.2013.2245058
View details for PubMedID 24761029
View details for PubMedCentralID PMC3993911
-
Emerging protein array technologies for proteomics
EXPERT REVIEW OF PROTEOMICS
2013; 10 (1): 65-75
Abstract
Numerous efforts have been made to understand fundamental biology of diseases based on gene expression. However, the relationship between gene expression and onset of disease often remains obscure. The great advances in protein microarrays allow us to investigate this unclear question through protein profiles, which are regarded as more reliable than gene expressions to serve as the harbinger of disease onset or as the biomarker of disease treatment monitoring. The authors review two relatively new platforms of protein arrays, along with an introduction to the common basis of protein array technologies. Immobilization of proteins on the surface of arrays and neutralizing reactive areas after the immobilization are key practical issues in the field of protein array. One of the emerging protein array technologies is the magneto-nanosensor array, where giant magnetoresistive sensors are used to quantitatively measure the analytes of interest, which are labeled with magnetic nanoparticles. Similar to giant magnetoresistive sensors, several different ways of utilizing magnetic properties for biomolecular detection have been developed and are reviewed here. Another emerging protein array technology is nucleic acid programmable protein arrays, which have thousands of protein features directly expressed by nucleic acids on the array surface. The authors anticipate that these two emerging protein array platforms can be combined to produce synergistic benefits and open new applications in proteomics and clinical diagnostics.
View details for DOI 10.1586/EPR.12.67
View details for PubMedID 23414360
-
Magnetically ultraresponsive nanoscavengers for next-generation water purification systems.
Nature communications
2013; 4: 1866-?
Abstract
The development of sustainable, robust and energy efficient water purification technology is still challenging. Although use of nanoparticles is promising, methods are needed for their efficient recovery post treatment. Here we address this issue by fabrication of magnetically ultraresponsive 'nanoscavengers', nanoparticles containing synthetic antiferromagnetic core layers and functional capping layers. When dispersed in water, the nanoscavengers efficiently interact with contaminants to remove them from the water. They are then quickly collected (<5 min) with a permanent magnet, owing to their magnetically ultraresponsive core layers. Specifically, we demonstrate fabrication and deployment of Ag-capped nanoscavengers for disinfection followed by application of an external magnetic field for separation. We also develop and validate a collision-based model for pathogen inactivation, and propose a cyclical water purification scheme in which nanoscavengers are recovered and recycled for contaminant removal.
View details for DOI 10.1038/ncomms2892
View details for PubMedID 23673651
-
Effect of Magnetic Field Gradient on Effectiveness of the Magnetic Sifter for Cell Purification.
IEEE transactions on magnetics
2013; 49 (1): 316-320
Abstract
In our experiments with NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen, we demonstrate capture efficiencies above 90% even at sample flow rates of 5 ml/h through our microfabricated magnetic sifter. We also improve the elution efficiencies from between 50% and 60% to close to 90% via optimization of the permanent magnet size and position used to magnetize the sifter. We then explain our observations via the use of finite element software for magnetic field and field gradient distributions, and a particle tracing algorithm, illustrating the impact of magnetic field gradients on the performance of the magnetic sifter. The high capture and elution efficiencies observed here is especially significant for magnetic separation of biologically interesting but rare moieties such as cancer stem cells for downstream analysis.
View details for DOI 10.1109/TMAG.2012.2224851
View details for PubMedID 23515873
View details for PubMedCentralID PMC3600415
-
Effect of Magnetic Field Gradient on Effectiveness of the Magnetic Sifter for Cell Purification
IEEE TRANSACTIONS ON MAGNETICS
2013; 49 (1): 316-320
Abstract
In our experiments with NCI-H1650 lung cancer cell lines labeled with magnetic nanoparticles via the Epithelial Cell Adhesion Molecule (EpCAM) antigen, we demonstrate capture efficiencies above 90% even at sample flow rates of 5 ml/h through our microfabricated magnetic sifter. We also improve the elution efficiencies from between 50% and 60% to close to 90% via optimization of the permanent magnet size and position used to magnetize the sifter. We then explain our observations via the use of finite element software for magnetic field and field gradient distributions, and a particle tracing algorithm, illustrating the impact of magnetic field gradients on the performance of the magnetic sifter. The high capture and elution efficiencies observed here is especially significant for magnetic separation of biologically interesting but rare moieties such as cancer stem cells for downstream analysis.
View details for DOI 10.1109/TMAG.2012.2224851
View details for Web of Science ID 000312831500027
View details for PubMedCentralID PMC3600415
-
Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation.
Scientific reports
2013; 3: 2234-?
Abstract
Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations showed excellent dose discrimination at ≥ 1 Gy in the time window of 1 to 7 days after exposure except 1 Gy at day 7. Saa1 dose response was limited to the first two days after exposure. A multiplex assay with both proteins showed improved dose classification accuracy. Our magneto-nanosensor assay demonstrates the dose and time responses, low-dose sensitivity, small volume requirements, and rapid speed that have important advantages in radiation triage biodosimetry.
View details for DOI 10.1038/srep02234
View details for PubMedID 23868657
-
DNA Repair and Cell Cycle Biomarkers of Radiation Exposure and Inflammation Stress in Human Blood
PLOS ONE
2012; 7 (11)
Abstract
DNA damage and repair are hallmarks of cellular responses to ionizing radiation. We hypothesized that monitoring the expression of DNA repair-associated genes would enhance the detection of individuals exposed to radiation versus other forms of physiological stress. We employed the human blood ex vivo radiation model to investigate the expression responses of DNA repair genes in repeated blood samples from healthy, non-smoking men and women exposed to 2 Gy of X-rays in the context of inflammation stress mimicked by the bacterial endotoxin lipopolysaccharide (LPS). Radiation exposure significantly modulated the transcript expression of 12 genes of 40 tested (2.2E-06
View details for DOI 10.1371/journal.pone.0048619
View details for Web of Science ID 000311935800084
View details for PubMedID 23144912
View details for PubMedCentralID PMC3492462
-
A Magneto-Nanosensor Immunoassay for Sensitive Detection of Aspergillus Fumigatus Allergen Asp f 1
International Magnetics Conference (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2012: 3266–68
Abstract
We report a magneto-nanosensor biochip for fungal detection. The chip is made of arrays of giant magnetoresistive (GMR) spin-valve sensors, and is able to detect protein biomarkers at low concentrations in solutions. As a demonstration, a standard curve for fungal pathogen Asp f 1 was obtained by measuring signals from various concentrations of Asp f 1 spiked in PBS solutions, indicating a detection limit of ~100 pg/ml. Five positive and negative Asp f 1 solution samples were discriminated correctly in blind experiments. Our data suggest that the magneto-nanosensor biochips are very promising as sensitive diagnostic devices for fungal pathogens. Given the generality of the detection scheme used in the magneto-nanosensor, we anticipate that the platform will be very useful for the detection of many types of biomarkers.
View details for DOI 10.1109/TMAG.2012.2195163
View details for Web of Science ID 000310194400137
View details for PubMedCentralID PMC3594507
-
A Magneto-Nanosensor Immunoassay for Sensitive Detection of Aspergillus Fumigatus Allergen Asp f 1.
IEEE transactions on magnetics
2012; 48 (11): 3266-3268
Abstract
We report a magneto-nanosensor biochip for fungal detection. The chip is made of arrays of giant magnetoresistive (GMR) spin-valve sensors, and is able to detect protein biomarkers at low concentrations in solutions. As a demonstration, a standard curve for fungal pathogen Asp f 1 was obtained by measuring signals from various concentrations of Asp f 1 spiked in PBS solutions, indicating a detection limit of ~100 pg/ml. Five positive and negative Asp f 1 solution samples were discriminated correctly in blind experiments. Our data suggest that the magneto-nanosensor biochips are very promising as sensitive diagnostic devices for fungal pathogens. Given the generality of the detection scheme used in the magneto-nanosensor, we anticipate that the platform will be very useful for the detection of many types of biomarkers.
View details for DOI 10.1109/TMAG.2012.2195163
View details for PubMedID 23494403
View details for PubMedCentralID PMC3594507
-
A Current Sensor Based on the Giant Magnetoresistance Effect: Design and Potential Smart Grid Applications
SENSORS
2012; 12 (11): 15520-15541
Abstract
Advanced sensing and measurement techniques are key technologies to realize a smart grid. The giant magnetoresistance (GMR) effect has revolutionized the fields of data storage and magnetic measurement. In this work, a design of a GMR current sensor based on a commercial analog GMR chip for applications in a smart grid is presented and discussed. Static, dynamic and thermal properties of the sensor were characterized. The characterizations showed that in the operation range from 0 to ±5 A, the sensor had a sensitivity of 28 mV·A(-1), linearity of 99.97%, maximum deviation of 2.717%, frequency response of −1.5 dB at 10 kHz current measurement, and maximum change of the amplitude response of 0.0335%·°C(-1) with thermal compensation. In the distributed real-time measurement and monitoring of a smart grid system, the GMR current sensor shows excellent performance and is cost effective, making it suitable for applications such as steady-state and transient-state monitoring. With the advantages of having a high sensitivity, high linearity, small volume, low cost, and simple structure, the GMR current sensor is promising for the measurement and monitoring of smart grids.
View details for DOI 10.3390/s121115520
View details for Web of Science ID 000311429500064
View details for PubMedID 23202221
View details for PubMedCentralID PMC3522974
-
Fluorescent Magnetic Nanoparticles for Magnetically Enhanced Cancer Imaging and Targeting in Living Subjects
ACS NANO
2012; 6 (8): 6862-6869
Abstract
Early detection and targeted therapy are two major challenges in the battle against cancer. Novel imaging contrast agents and targeting approaches are greatly needed to improve the sensitivity and specificity of cancer theranostic agents. Here, we implemented a novel approach using a magnetic micromesh and biocompatible fluorescent magnetic nanoparticles (FMN) to magnetically enhance cancer targeting in living subjects. This approach enables magnetic targeting of systemically administered individual FMN, containing a single 8 nm superparamagnetic iron oxide core. Using a human glioblastoma mouse model, we show that nanoparticles can be magnetically retained in both the tumor neovasculature and surrounding tumor tissues. Magnetic accumulation of nanoparticles within the neovasculature was observable by fluorescence intravital microscopy in real time. Finally, we demonstrate that such magnetically enhanced cancer targeting augments the biological functions of molecules linked to the nanoparticle surface.
View details for DOI 10.1021/nn301670a
View details for Web of Science ID 000307988900039
View details for PubMedID 22857784
View details for PubMedCentralID PMC3601027
-
Axonal Traffic Control in Live Neurons by Tailor-Designed Magnetic Forces
CELL PRESS. 2012: 379A
View details for DOI 10.1016/j.bpj.2011.11.2074
View details for Web of Science ID 000321561202507
-
Spin wave modes in ferromagnetic tubes
JOURNAL OF APPLIED PHYSICS
2012; 111 (1)
View details for DOI 10.1063/1.3672835
View details for Web of Science ID 000299127200058
-
Nano-tools to battle cancer: magnetic nanotags, protein chips and cell sorters
IEEE. 2012
View details for Web of Science ID 000322438500090
-
GMR Spin-Valve Biosensors
HANDBOOK OF SPIN TRANSPORT AND MAGNETISM
2012: 715–29
View details for Web of Science ID 000356247000038
-
Raman-Active Two-Tiered Ag Nanoparticles with a Concentric Cavity
SMALL
2011; 7 (23): 3276-3280
Abstract
A two-tiered Ag nanoparticle containing a cavity at the center of each nanoparticle is generated by two simple steps of nano-imprinting and metal vacuum deposition. It enables sub-zeptomole detection of organic molecules and five orders of the dynamic sensing range.
View details for DOI 10.1002/smll.201101523
View details for Web of Science ID 000298288100004
View details for PubMedID 21990231
View details for PubMedCentralID PMC3595186
-
Sombrero-Shaped Plasmonic Nanoparticles with Molecular-Level Sensitivity and Multifunctionality
ACS NANO
2011; 5 (8): 6449-6457
Abstract
We demonstrate top-down synthesis of monodisperse plasmonic nanoparticles designed to contain internal Raman hot spots. Our Raman-active nanoparticles are fabricated using nanoimprint lithography and thin-film deposition and are composed of novel internal structures with sublithographic dimensions: a disk-shaped Ag core, a Petri-dish-shaped SiO(2) base whose inner surface is coated with Ag film, and a sub-10 nm scale circular gap between the core and the base. Confocal Raman measurements and electromagnetic simulations show that Raman hot spots appear at the inside perimeter of individual nanoparticles and serve as the source of a 1000-fold improvement of minimum molecular detection level that enables detection of signals from a few molecules near hot spots. A multimodality version of these nanoparticles, which includes the functionality offered by magnetic multilayers, is also demonstrated. These results illustrate the potential of direct fabrication for creating exotic monodisperse nanoparticles, which combine engineered internal nanostructures and multilayer composite materials, for use in nanoparticle-based molecular imaging and detection.
View details for DOI 10.1021/nn201649n
View details for Web of Science ID 000294085400044
View details for PubMedID 21732686
View details for PubMedCentralID PMC3160147
-
Silicon nano-well arrays for reliable pattern transfer and locally confined high temperature reactions
NANOTECHNOLOGY
2011; 22 (30)
Abstract
Si nano-well arrays, with precisely controlled undercut Si sidewall profiles and flat bottomed pockets, enable uniform nanoscale pattern transfer from resists to metal deposits without degradation of the initial lithographic resolution, as verified by the formation of arrays of Au nano-dots with 10 nm diameter. An additional functionality of the Si nano-wells as local nano-reactors, where the patterned material is enclosed in a Si pocket during high temperature reaction, is demonstrated by thermally inducing a phase transformation of the as-deposited A1 phase of FePt nano-dots to the high coercivity, chemically ordered L1(0) phase.
View details for DOI 10.1088/0957-4484/22/30/305304
View details for Web of Science ID 000292455300006
View details for PubMedID 21709347
View details for PubMedCentralID PMC3167870
-
Autoassembly Protein Arrays for Analyzing Antibody Cross-Reactivity
NANO LETTERS
2011; 11 (7): 2579-2583
Abstract
We report an autoassembly protein array capable of rapidly screening for aberrant antibody-antigen binding events. Our technique combines magnetic nanoparticle technology with proximity-based, magnetically responsive nanosensors for rapid (under 15 min) and high-density screening of antibody cross-reactivity at sensitivities down to 50 fM in a homogeneous assay. This method will enable the identification of the precise cause of aberrant or cross-reactive binding events in an easy-to-use, rapid, and high-throughput manner.
View details for DOI 10.1021/nl1026056
View details for Web of Science ID 000292849400001
View details for PubMedID 20804215
View details for PubMedCentralID PMC3136110
-
Fabrication of planar, layered nanoparticles using tri-layer resist templates
NANOTECHNOLOGY
2011; 22 (18)
Abstract
A simple and universal pathway to produce free multilayer synthetic nanoparticles is developed based on lithography, vapor phase deposition and a tri-layer resist lift-off and release process. The fabrication method presented in this work is ideal for production of a broad range of nanoparticles, either free in solution or still attached to an intact release layer, with unique magnetic, optical, radioactive, electronic and catalytic properties. Multi-modal capabilities are implicit in the layered architecture. As an example, directly fabricated magnetic nanoparticles are evaluated to illustrate the structural integrity of thin internal multilayers and the nanoparticle stability in aggressive biological environments, which is highly desired for biomedical applications.
View details for DOI 10.1088/0957-4484/22/18/185302
View details for Web of Science ID 000288653300005
View details for PubMedID 21415483
View details for PubMedCentralID PMC3143003
-
Gradual pressure release for reliable nanoimprint lithography
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B
2011; 29 (3)
View details for DOI 10.1116/1.3574390
View details for Web of Science ID 000291111300036
-
Quantification of protein interactions and solution transport using high-density GMR sensor arrays
NATURE NANOTECHNOLOGY
2011; 6 (5): 314-320
Abstract
Monitoring the kinetics of protein interactions on a high-density sensor array is vital to drug development and proteomic analysis. Label-free kinetic assays based on surface plasmon resonance are the current gold standard, but they have poor detection limits, suffer from non-specific binding, and are not amenable to high-throughput analyses. Here, we show that magnetically responsive nanosensors that have been scaled to over 100,000 sensors per cm² can be used to measure the binding kinetics of various proteins with high spatial and temporal resolution. We present an analytical model that describes the binding of magnetically labelled antibodies to proteins that are immobilized on the sensor surface. This model is able to quantify the kinetics of antibody-antigen binding at sensitivities as low as 20 zeptomoles of solute.
View details for DOI 10.1038/NNANO.2011.45
View details for Web of Science ID 000290301300013
View details for PubMedID 21478869
View details for PubMedCentralID PMC3089684
-
Micro-structured ferromagnetic tubes for spin wave excitation
JOURNAL OF APPLIED PHYSICS
2011; 109 (7)
View details for DOI 10.1063/1.3559475
View details for Web of Science ID 000289952100198
-
Magnetic, Mechanical, and Optical Characterization of a Magnetic Nanoparticle-Embedded Polymer for Microactuation
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS
2011; 20 (1): 65-72
View details for DOI 10.1109/JMEMS.2010.2093560
View details for Web of Science ID 000286934900012
-
nanoLAB: An ultraportable, handheld diagnostic laboratory for global health
LAB ON A CHIP
2011; 11 (5): 950-956
Abstract
Driven by scientific progress and economic stimulus, medical diagnostics will move to a stage in which straightforward medical diagnoses are independent of physician visits and large centralized laboratories. The future of basic diagnostic medicine will lie in the hands of private individuals. We have taken significant strides towards achieving this goal by developing an autoassembly assay for disease biomarker detection which obviates the need for washing steps and is run on a handheld sensing platform. By coupling magnetic nanotechnology with an array of magnetically responsive nanosensors, we demonstrate a rapid, multiplex immunoassay that eliminates the need for trained technicians to run molecular diagnostic tests. Furthermore, the platform is battery-powered and ultraportable, allowing the assay to be run anywhere in the world by any individual.
View details for DOI 10.1039/c0lc00534g
View details for Web of Science ID 000287409600024
View details for PubMedID 21264375
-
Portable Biomarker Detection with Magnetic Nanotags.
The ... Midwest Symposium on Circuits and Systems conference proceedings : MWSCAS. Midwest Symposium on Circuits and Systems
2010: 1779-1782
Abstract
This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications.
View details for DOI 10.1109/ISCAS.2010.5537639
View details for PubMedID 22495252
View details for PubMedCentralID PMC3321410
-
Magneto-Nano Chips for Ultrasensitive and Multiplex Detection of Biomarkers of Tumor and Exposure
41st Annual Meeting of Environmental-Mutagen-Society
WILEY-BLACKWELL. 2010: 699–99
View details for Web of Science ID 000281009600059
-
Effects of Ionizing Radiation on Self-Renewal and Pluripotency of Human Embryonic Stem Cells
CANCER RESEARCH
2010; 70 (13): 5539-5548
Abstract
Human embryonic stem cells (hESC) present a novel platform for in vitro investigation of the early embryonic cellular response to ionizing radiation. Thus far, no study has analyzed the genome-wide transcriptional response to ionizing radiation in hESCs, nor has any study assessed their ability to form teratomas, the definitive test of pluripotency. In this study, we use microarrays to analyze the global gene expression changes in hESCs after low-dose (0.4 Gy), medium-dose (2 Gy), and high-dose (4 Gy) irradiation. We identify genes and pathways at each radiation dose that are involved in cell death, p53 signaling, cell cycling, cancer, embryonic and organ development, and others. Using Gene Set Enrichment Analysis, we also show that the expression of a comprehensive set of core embryonic transcription factors is not altered by radiation at any dose. Transplantation of irradiated hESCs to immune-deficient mice results in teratoma formation from hESCs irradiated at all doses, definitive proof of pluripotency. Further, using a bioluminescence imaging technique, we have found that irradiation causes hESCs to initially die after transplantation, but the surviving cells quickly recover by 2 weeks to levels similar to control. To conclude, we show that similar to somatic cells, irradiated hESCs suffer significant death and apoptosis after irradiation. However, they continue to remain pluripotent and are able to form all three embryonic germ layers. Studies such as this will help define the limits for radiation exposure for pregnant women and also radiotracer reporter probes for tracking cellular regenerative therapies.
View details for DOI 10.1158/0008-5472.CAN-09-4238
View details for PubMedID 20530673
-
Analysis of Integrated Solenoid Inductor With Closed Magnetic Core
IEEE TRANSACTIONS ON MAGNETICS
2010; 46 (6): 2387-2390
View details for DOI 10.1109/TMAG.2010.2044982
View details for Web of Science ID 000278037800288
-
GMR biosensor arrays: Correction techniques for reproducibility and enhanced sensitivity
BIOSENSORS & BIOELECTRONICS
2010; 25 (9): 2177-2181
Abstract
Giant magnetoresistive biosensors possess great potential in biomedical applications for quantitatively detecting magnetically tagged biomolecules. Magnetic sensing does not suffer from the high background levels found in optical sensing modalities such as the enzyme linked immunosorbent assay translating into a technology with higher sensitivity. However, to reveal the full potential of these sensors and compensate for non-idealities such as temperature dependence, digital correction and calibration techniques are not only useful but imperative. Using these calibration techniques to correct for process variations and dynamic changes in the sensing environment (such as temperature and magnetic field), we are able to obtain extremely sensitive and, more importantly, reproducible results for quantifiable biomolecular reorganization. The reproducibility of the system was improved by over 3 x using digital correction techniques and the sensors are made temperature independent by using a novel background correction technique.
View details for DOI 10.1016/j.bios.2010.01.039
View details for Web of Science ID 000277930000029
View details for PubMedID 20219342
View details for PubMedCentralID PMC2881564
-
GMR biosensor arrays: A system perspective
BIOSENSORS & BIOELECTRONICS
2010; 25 (9): 2051-2057
Abstract
Giant magnetoresistive biosensors are becoming more prevalent for sensitive, quantifiable biomolecular detection. However, in order for magnetic biosensing to become competitive with current optical protein microarray technology, there is a need to increase the number of sensors while maintaining the high sensitivity and fast readout time characteristic of smaller arrays (1-8 sensors). In this paper, we present a circuit architecture scalable for larger sensor arrays (64 individually addressable sensors) while maintaining a high readout rate (scanning the entire array in less than 4s). The system utilizes both time domain multiplexing and frequency domain multiplexing in order to achieve this scan rate. For the implementation, we propose a new circuit architecture that does not use a classical Wheatstone bridge to measure the small change in resistance of the sensor. Instead, an architecture designed around a transimpedance amplifier is employed. A detailed analysis of this architecture including the noise, distortion, and potential sources of errors is presented, followed by a global optimization strategy for the entire system comprising the magnetic tags, sensors, and interface electronics. To demonstrate the sensitivity, quantifiable detection of two blindly spiked samples of unknown concentrations has been performed at concentrations below the limit of detection for the enzyme-linked immunosorbent assay. Lastly, the multiplexing capability and reproducibility of the system was demonstrated by simultaneously monitoring sensors functionalized with three unique proteins at different concentrations in real-time.
View details for DOI 10.1016/j.bios.2010.01.038
View details for Web of Science ID 000277930000009
View details for PubMedID 20207130
View details for PubMedCentralID PMC2855856
-
Silane-based functionalization of synthetic antiferromagnetic nanoparticles for biomedical applications
11th Joint MMM-Intermag Conference
AMER INST PHYSICS. 2010
Abstract
Synthetic antiferromagnetic nanoparticles (SAFNPs) have been successfully coated with two different kinds of silanes, 3-aminopropyltrimethoxysilane and 2-[methoxy(polyethyleneoxy)propyl]trimethoxysilane. The morphology of SAF particles is characterized by scanning electron microscopy and magnetic properties by alternating gradient magnetometry. The attachment of silane molecules is verified by Fourier-transform infrared spectroscopy and colloidal stability is studied using dynamic light scattering. These two silanes change the surface chemical properties of SAFNPs dramatically in different ways, which in turn affects the stability of these particles.
View details for DOI 10.1063/1.3355906
View details for Web of Science ID 000277834300201
View details for PubMedCentralID PMC2884041
-
Structural and magnetic characterizations of high moment synthetic antiferromagnetic nanoparticles fabricated using self-assembled stamps
11th Joint MMM-Intermag Conference
AMER INST PHYSICS. 2010
View details for DOI 10.1063/1.3358067
View details for Web of Science ID 000277834300225
-
Magnetic Nanotechnology for Biodetection
JALA
2010; 15 (2): 93-98
View details for DOI 10.1016/j.jala.2009.10.008
View details for Web of Science ID 000285163500004
-
Sensitive giant magnetoresistive-based immunoassay for multiplex mycotoxin detection
BIOSENSORS & BIOELECTRONICS
2010; 25 (7): 1635-1639
Abstract
Rapid and multiplexed measurement is vital in the detection of food-borne pathogens. While highly specific and sensitive, traditional immunochemical assays such as enzyme-linked immunosorbent assays (ELISAs) often require expensive read-out equipment (e.g. fluorescent labels) and lack the capability of multiplex detection. By combining the superior specificity of immunoassays with the sensitivity and simplicity of magnetic detection, we have developed a novel multiplex magnetic nanotag-based detection platform for mycotoxins that functions on a sub-picomolar concentration level. Unlike fluorescent labels, magnetic nanotags (MNTs) can be detected with inexpensive giant magnetoresistive (GMR) sensors such as spin-valve sensors. In the system presented here, each spin-valve sensor has an active area of 90 microm x 90 microm, arranged in an 8 x 8 array. Sample is added to the antibody-immobilized sensor array prior to the addition of the biotinylated detection antibody. The sensor response is recorded in real time upon the addition of streptavidin-linked MNTs on the chip. Here we demonstrate the simultaneous detection of multiple mycotoxins (aflatoxins B(1), zearalenone and HT-2) and show that a detection limit of 50 pg/mL can be achieved.
View details for DOI 10.1016/j.bios.2009.11.028
View details for Web of Science ID 000275978700013
View details for PubMedID 20047828
View details for PubMedCentralID PMC2947153
-
The influence of Fermi level pinning/depinning on the Schottky barrier height and contact resistance in Ge/CoFeB and Ge/MgO/CoFeB structures
APPLIED PHYSICS LETTERS
2010; 96 (5)
View details for DOI 10.1063/1.3285163
View details for Web of Science ID 000274319500073
-
Detection of a single synthetic antiferromagnetic nanoparticle with an AMR nanostructure: comparison between simulations and experiments
International Conference on Magnetism (ICM 2009)
IOP PUBLISHING LTD. 2010
View details for DOI 10.1088/1742-6596/200/12/122001
View details for Web of Science ID 000291321303100
-
Portable Biomarker Detection with Magnetic Nanotags
International Symposium on Circuits and Systems Nano-Bio Circuit Fabrics and Systems (ISCAS 2010)
IEEE. 2010: 1779–82
Abstract
This paper presents a hand-held, portable biosensor platform for quantitative biomarker measurement. By combining magnetic nanoparticle (MNP) tags with giant magnetoresistive (GMR) spin-valve sensors, the hand-held platform achieves highly sensitive (picomolar) and specific biomarker detection in less than 20 minutes. The rapid analysis and potential low cost make this technology ideal for point-of-care (POC) diagnostics. Furthermore, this platform is able to detect multiple biomarkers simultaneously in a single assay, creating a promising diagnostic tool for a vast number of applications.
View details for Web of Science ID 000287216002001
View details for PubMedCentralID PMC3321410
-
Matrix-insensitive protein assays push the limits of biosensors in medicine
NATURE MEDICINE
2009; 15 (11): 1327-U130
Abstract
Advances in biosensor technologies for in vitro diagnostics have the potential to transform the practice of medicine. Despite considerable work in the biosensor field, there is still no general sensing platform that can be ubiquitously applied to detect the constellation of biomolecules in diverse clinical samples (for example, serum, urine, cell lysates or saliva) with high sensitivity and large linear dynamic range. A major limitation confounding other technologies is signal distortion that occurs in various matrices due to heterogeneity in ionic strength, pH, temperature and autofluorescence. Here we present a magnetic nanosensor technology that is matrix insensitive yet still capable of rapid, multiplex protein detection with resolution down to attomolar concentrations and extensive linear dynamic range. The matrix insensitivity of our platform to various media demonstrates that our magnetic nanosensor technology can be directly applied to a variety of settings such as molecular biology, clinical diagnostics and biodefense.
View details for DOI 10.1038/nm.2032
View details for Web of Science ID 000271543700023
View details for PubMedID 19820717
-
Small-Resistance and High-Quality-Factor Magnetic Integrated Inductors on PCB
IEEE TRANSACTIONS ON ADVANCED PACKAGING
2009; 32 (4): 780-787
View details for DOI 10.1109/TADVP.2009.2019845
View details for Web of Science ID 000271435900010
-
Designs for a Microfabricated Magnetic Sifter
International Magnetics Conference 2009 (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2009: 4884–87
View details for DOI 10.1109/TMAG.2009.2026486
View details for Web of Science ID 000270149700376
-
Magnetostatic Spin-Wave Modes in Ferromagnetic Tube
International Magnetics Conference 2009 (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2009: 4223–25
View details for DOI 10.1109/TMAG.2009.2023919
View details for Web of Science ID 000270149700209
-
Nonreciprocal Spin Waves in Co-Ta-Zr Films and Multilayers
International Magnetics Conference 2009 (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2009: 4215–18
View details for DOI 10.1109/TMAG.2009.2022491
View details for Web of Science ID 000270149700207
-
Nanosized corners for trapping and detecting magnetic nanoparticles
NANOTECHNOLOGY
2009; 20 (38)
Abstract
We present a device concept based on controlled micromagnetic configurations in a corner-shaped permalloy nanostructure terminated with two circular disks, specifically designed for the capture and detection of a small number of magnetic beads in suspension. A transverse head-to-head domain wall (TDW) placed at the corner of the structure plays the role of an attracting pole for magnetic beads. The TDW is annihilated in the terminating disks by applying an appropriate magnetic field, whose value is affected by the presence of beads chemically bound to the surface. In the case where the beads are not chemically bound to the surface, the annihilation of the TDW causes their release into the suspension. The variation of the voltage drop across the corner, due to the anisotropic magnetoresistance (AMR) while sweeping the magnetic field, is used to detect the presence of a chemically bound bead. The device response has been characterized by using both synthetic antiferromagnetic nanoparticles (disks of 70 nm diameter and 20 nm height) and magnetic nanobeads, for different thicknesses of the protective capping layer. We demonstrate the detection down to a single nanoparticle, therefore the device holds the potential for the localization and detection of small numbers of molecules immobilized on the particle's functionalized surface.
View details for DOI 10.1088/0957-4484/20/38/385501
View details for Web of Science ID 000269356900009
View details for PubMedID 19713593
-
Visualizing Implanted Tumors in Mice with Magnetic Resonance Imaging Using Magnetotactic Bacteria
CLINICAL CANCER RESEARCH
2009; 15 (16): 5170-5177
Abstract
To determine if magnetotactic bacteria can target tumors in mice and provide positive contrast for visualization using magnetic resonance imaging.The ability of the magnetotactic bacterium, Magnetospirillum magneticum AMB-1 (referred to from here as AMB-1), to confer positive magnetic resonance imaging contrast was determined in vitro and in vivo. For the latter studies, AMB-1 were injected either i.t. or i.v. Bacterial growth conditions were manipulated to produce small (approximately 25-nm diameter) magnetite particles, which were observed using transmission electron microscopy. Tumor targeting was confirmed using 64Cu-labeled bacteria and positron emission tomography and by determination of viable cell counts recovered from different organs and the tumor.We show that AMB-1 bacteria with small magnetite particles generate T1-weighted positive contrast, enhancing in vivo visualization by magnetic resonance imaging. Following i.v. injection of 64Cu-labeled AMB-1, positron emission tomography imaging revealed increasing colonization of tumors and decreasing infection of organs after 4 hours. Viable cell counts showed that, by day 6, the bacteria had colonized tumors but were cleared completely from other organs. Magnetic resonance imaging showed a 1.22-fold (P = 0.003) increased positive contrast in tumors on day 2 and a 1.39-fold increase (P = 0.0007) on day 6.Magnetotactic bacteria can produce positive magnetic resonance imaging contrast and colonize mouse tumor xenografts, providing a potential tool for improved magnetic resonance imaging visualization in preclinical and translational studies to track cancer.
View details for DOI 10.1158/1078-0432.CCR-08-3206
View details for Web of Science ID 000269024900019
View details for PubMedID 19671860
View details for PubMedCentralID PMC3409839
-
High Resolution Crystal Structure of the Methylcobalamin Analogues Ethylcobalamin and Butylcobalamin by X-ray Synchrotron Diffraction
INORGANIC CHEMISTRY
2009; 48 (14): 6615-6622
Abstract
The X-ray crystal structures of the methylcobalamin (MeCbl) analogues ethylcobalamin (EtCbl) and butylcobalamin (BuCbl) are reported. The X-ray crystal structures of EtCbl and BuCbl were obtained with some of the lowest crystallographic residuals ever achieved for cobalamins (R = 0.0468 and 0.0438, respectively). The Co-C bond distances for EtCbl and BuCbl are 2.023(2) and 2.028(4) A, whereas the Co-alpha-5,6-dimethylbenzimidazole (Co-N3B) bond distances were 2.232(1) and 2.244(1) A, respectively. Although EtCbl and BuCbl displayed a longer Co-N3B bond than that observed in the naturally occurring methylcobalamin, the orientation of the alpha-5,6-dimethylbenzimidazole moiety with respect to the corrin ring did not vary substantially among the structures. The lengthening of both Co-C and Co-N3B bonds in EtCbl and BuCbl can be attributed to the "inverse" trans influence exerted by the sigma-donating alkyl groups, typically observed in alkylcobalamins. Analysis of the molecular surface maps showed that the alkyl ligands in EtCbl and BuCbl are directed toward the hydrophobic side of the corrin ring. The corrin fold angles in EtCbl and BuCbl were determined to be 14.7 degrees and 13.1 degrees, respectively. A rough correlation exists between the corrin fold angle and the length of the Co-N3B bond, and both alkylcobalamins follow the same trend.
View details for DOI 10.1021/ic900590p
View details for Web of Science ID 000268137900042
View details for PubMedID 19545130
View details for PubMedCentralID PMC2878369
-
Cryogenic tilt table
INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING
2009; 10 (3): 37-42
View details for DOI 10.1007/s12541-009-0045-9
View details for Web of Science ID 000268009600006
-
Formation and properties of magnetic chains for 100nm nanoparticles used in separations of molecules and cells
7th International Conference on Scientific and Clinical Applications of Magnetic Carriers
ELSEVIER SCIENCE BV. 2009: 1452–58
Abstract
Optical observations of 100 nm metallic magnetic nanoparticles are used to study their magnetic field induced self assembly. Chains with lengths of tens of microns are observed to form within minutes at nanoparticle concentrations of 10(10) per mL. Chain rotation and magnetophoresis are readily observed, and SEM reveals that long chains are not simple single particle filaments. Similar chains are detected for several 100 nm commercial bio-separation nanoparticles. We demonstrate the staged magnetic condensation of different types of nanoparticles into composite structures and show that magnetic chains bind to immunomagnetically labeled cells, serving as temporary handles which allow novel magnetic cell manipulations.
View details for DOI 10.1016/j.jmmm.2009.02.066
View details for Web of Science ID 000265278000028
View details for PubMedCentralID PMC2757286
-
Formation and properties of magnetic chains for 100 nm nanoparticles used in separations of molecules and cells.
Journal of magnetism and magnetic materials
2009; 321 (10): 1452-1458
Abstract
Optical observations of 100 nm metallic magnetic nanoparticles are used to study their magnetic field induced self assembly. Chains with lengths of tens of microns are observed to form within minutes at nanoparticle concentrations of 10(10) per mL. Chain rotation and magnetophoresis are readily observed, and SEM reveals that long chains are not simple single particle filaments. Similar chains are detected for several 100 nm commercial bio-separation nanoparticles. We demonstrate the staged magnetic condensation of different types of nanoparticles into composite structures and show that magnetic chains bind to immunomagnetically labeled cells, serving as temporary handles which allow novel magnetic cell manipulations.
View details for DOI 10.1016/j.jmmm.2009.02.066
View details for PubMedID 20161001
View details for PubMedCentralID PMC2757286
-
Microfabricated magnetic sifter for high-throughput and high-gradient magnetic separation.
Journal of magnetism and magnetic materials
2009; 321 (10): 1436-1439
Abstract
A microfabricated magnetic sifter has been designed and fabricated for applications in biological sample preparation. The device enables high-throughput, high-gradient magnetic separation of magnetic nanoparticles by utilizing columnar fluid flow through a dense array (~5000/mm(2)) of micropatterned slots in a magnetically soft membrane. The potential of the sifter for separation of magnetic nanoparticles conjugated with capture antibodies is demonstrated through quantitative separation experiments with CD138-labelled MACS nanoparticles. Capture efficiencies ranging from 28-37% and elution efficiencies greater than 73% were measured for a single pass through the sifter.
View details for DOI 10.1016/j.jmmm.2009.02.062
View details for PubMedID 20161248
View details for PubMedCentralID PMC2707938
-
Microfabricated magnetic sifter for high-throughput and high-gradient magnetic separation
7th International Conference on Scientific and Clinical Applications of Magnetic Carriers
ELSEVIER SCIENCE BV. 2009: 1436–39
Abstract
A microfabricated magnetic sifter has been designed and fabricated for applications in biological sample preparation. The device enables high-throughput, high-gradient magnetic separation of magnetic nanoparticles by utilizing columnar fluid flow through a dense array (~5000/mm(2)) of micropatterned slots in a magnetically soft membrane. The potential of the sifter for separation of magnetic nanoparticles conjugated with capture antibodies is demonstrated through quantitative separation experiments with CD138-labelled MACS nanoparticles. Capture efficiencies ranging from 28-37% and elution efficiencies greater than 73% were measured for a single pass through the sifter.
View details for DOI 10.1016/j.jmmm.2009.02.062
View details for Web of Science ID 000265278000025
View details for PubMedCentralID PMC2707938
-
Synthetic antiferromagnetic nanoparticles with tunable susceptibilities
53rd Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2009
Abstract
High-moment monodisperse disk-shaped Co-Fe magnetic nanoparticles, stable in aqueous solution, were physically fabricated by using nanoimprinted templates and vacuum deposition techniques. These multilayer synthetic antiferromagnetic nanoparticles exhibit nearly zero magnetic remanence and coercivity, and susceptibilities which can be tuned by exploiting interlayer magnetic interactions. In addition, a low cost method of scaling up the production of sub-100 nm synthetic antiferromagnetic nanoparticles is demonstrated.
View details for DOI 10.1063/1.3072028
View details for Web of Science ID 000266633500313
View details for PubMedCentralID PMC2685219
-
Dispersion and spin wave "tunneling" in nanostructured magnetostatic spin waveguides
53rd Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2009
View details for DOI 10.1063/1.3079767
View details for Web of Science ID 000266633500535
-
Effects of polyhydroxy compounds on beetle antifreeze protein activity
BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS
2009; 1794 (2): 341-346
Abstract
Antifreeze proteins (AFPs) noncolligatively depress the nonequilibrium freezing point of a solution and produce a difference between the melting and freezing points termed thermal hysteresis (TH). Some low-molecular-mass solutes can affect the TH values. The TH enhancement effects of selected polyhydroxy compounds including polyols and carbohydrates on an AFP from the beetle Dendroides canadensis were systematically investigated using differential scanning calorimetry (DSC). The number of hydroxyl groups dominates the molar enhancement effectiveness of polyhydroxy compounds having one to five hydroxyl groups. However, the above rule does not apply for polyhydroxy compounds having more than five hydroxyl groups. The most efficient polyhydroxy enhancer identified is trehalose. In a combination of enhancers the strongest enhancer plays the major role in determining the TH enhancement. Mechanistic insights into identification of highly efficient AFP enhancers are discussed.
View details for DOI 10.1016/j.bbapap.2008.10.011
View details for Web of Science ID 000262952600022
View details for PubMedID 19038370
-
Dispersion in magnetostatic CoTaZr spin waveguides
APPLIED PHYSICS LETTERS
2009; 94 (1)
View details for DOI 10.1063/1.3063124
View details for Web of Science ID 000262357800053
-
Gravity Probe B(*)
RIVISTA DEL NUOVO CIMENTO
2009; 32 (11): 555-589
View details for DOI 10.1393/ncr/i2009-10049-y
View details for Web of Science ID 000273677400001
-
MagArray Biochips for Protein and DNA Detection with Magnetic Nanotags: Design, Experiment, and Signal-to-Noise Ratio
MICROARRAYS: PREPARATION, MICROFLUIDICS, DETECTION METHODS, AND BIOLOGICAL APPLICATIONS
2009: 299–314
View details for DOI 10.1007/978-0-387-72719-6_15
View details for Web of Science ID 000267419200015
-
On-Package Magnetic Materials for Embedded Inductor Applications
IEEE. 2009: 395-+
View details for Web of Science ID 000289501700083
-
Biological Variations in Depression and Anxiety Between East and West
CNS NEUROSCIENCE & THERAPEUTICS
2009; 15 (3): 283-294
Abstract
Ethnicity and culture represent important factors in shaping psychopathology as well as pharmacotherapeutic responses in psychiatric patients. A large body of literature, accumulated over the past several decades, demonstrates that these factors not only determine the metabolism and disposition of medications (pharmacokinetics), but also their interactions with therapeutic targets (pharmacodynamics). This article focuses on the impact of such variations on the diagnosis and treatment of depression and anxiety disorders between East and West. Genes controlling the expression of drug metabolizing enzymes as well as the function of the brain are highly polymorphic, and the patterns and distribution of these polymorphisms are typically divergent across ethnic groups. To the extent that these genetic patterns determine drug response, ethnic variations in these genetic dispositions will lead to differential responses in clinical settings. In addition, the expression of these genes is significantly influenced by environmental factors including diet as well as exposure to other natural products. Superimposed on these biological influences, culturally determined beliefs and behavioral patterns also profoundly influence patients' expectations of treatment response, adherence, and interactions with clinicians. In addition to pharmacotherapeutic responses, emerging data also indicate that significant ethnic variations exist in genetic polymorphisms and neurobiologic correlates (biomarkers) that may be associated with the vulnerability to psychiatric disorders. These considerations argue for the importance of examining biological variations across ethnic groups, especially in the clinical context, in terms of the assessment and treatment of psychiatric patients, and in our understanding of psychiatric phenomenology and nosology.
View details for DOI 10.1111/j.1755-5949.2009.00093.x
View details for Web of Science ID 000268790700010
View details for PubMedID 19691548
-
Genome-wide transcriptome analysis of 150 cell samples
INTEGRATIVE BIOLOGY
2009; 1 (1): 99-107
Abstract
A major challenge in molecular biology is interrogating the human transcriptome on a genome wide scale when only a limited amount of biological sample is available for analysis. Current methodologies using microarray technologies for simultaneously monitoring mRNA transcription levels require nanogram amounts of total RNA. To overcome the sample size limitation of current technologies, we have developed a method to probe the global gene expression in biological samples as small as 150 cells, or the equivalent of approximately 300 pg total RNA. The new method employs microfluidic devices for the purification of total RNA from mammalian cells and ultra-sensitive whole transcriptome amplification techniques. We verified that the RNA integrity is preserved through the isolation process, accomplished highly reproducible whole transcriptome analysis, and established high correlation between repeated isolations of 150 cells and the same cell culture sample. We validated the technology by demonstrating that the combined microfluidic and amplification protocol is capable of identifying biological pathways perturbed by stimulation, which are consistent with the information recognized in bulk-isolated samples.
View details for DOI 10.1039/b814329c
View details for Web of Science ID 000266978200011
View details for PubMedID 20023796
-
Protein-Functionalized Synthetic Antiferromagnetic Nanoparticles for Biomolecule Detection and Magnetic Manipulation
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION
2009; 48 (9): 1620-1624
Abstract
Direct protein functionalization provides synthetic antiferromagnetic nanoparticles with high chemical specificity and multifunctionality. These nanoparticle-protein conjugates function as improved magnetic labels for biological detection experiments, and exhibit tunable responses to a small external magnetic field gradient, thus allowing the observation of distinctive single nanoparticle motion.
View details for DOI 10.1002/anie.200803994
View details for Web of Science ID 000263642300018
View details for PubMedID 19156803
View details for PubMedCentralID PMC2665302
-
A Prospective Randomized Pilot Study of Site-specific Atlas Incorporation into Target Volume Delineation Instructions in the Cooperative Group Setting: Preliminary Results from a Southwest Oncology Group Pilot using Big Brother
51st Annual Meeting of the American-Society-for-Radiation-Oncology (ASTRO)
ELSEVIER SCIENCE INC. 2009: S136–S137
View details for Web of Science ID 000270573600292
-
Multiplex protein assays based on real-time magnetic nanotag sensing
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA
2008; 105 (52): 20637-20640
Abstract
Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.
View details for DOI 10.1073/pnas.0810822105
View details for Web of Science ID 000262092800015
View details for PubMedID 19074273
View details for PubMedCentralID PMC2602607
-
Inhibition of Drosophila Wg Signaling Involves Competition between Mad and Armadillo/beta-Catenin for dTcf Binding
PLOS ONE
2008; 3 (12)
Abstract
Precisely regulated signal transduction pathways are crucial for the regulation of developmental events and prevention of tumorigenesis. Both the Transforming Growth Factor beta (TGFbeta)/Bone morphogenetic protein (BMP) and Wnt/Wingless (Wg) pathways play essential roles in organismal patterning and growth, and their deregulation can lead to cancers. We describe a mechanism of interaction between Drosophila Wg and BMP signaling in which Wg target gene expression is antagonized by BMP signaling. In vivo, high levels of both an activated BMP receptor and the BMP effector Mad can inhibit the expression of Wg target genes. Conversely, loss of mad can induce Wg target gene expression. In addition, we find that ectopic expression in vivo of the Wg transcription factor dTcf is able to suppress the inhibitory effect caused by ectopic Mad. In vitro binding studies revealed competition for dTcf binding between Mad and the Wnt effector beta-catenin/Armadillo (Arm). Our in vivo genetic analyses and target gene studies support a mechanism consistent with the in vitro binding and competition studies, namely that BMP pathway components can repress Wg target gene expression by influencing the binding of Arm and dTcf.
View details for DOI 10.1371/journal.pone.0003893
View details for Web of Science ID 000265455200008
View details for PubMedID 19065265
View details for PubMedCentralID PMC2587708
-
Incidence of lymphoid neoplasms by subtype among six Asian ethnic groups in the United States, 1996-2004
CANCER CAUSES & CONTROL
2008; 19 (10): 1171-1181
Abstract
To establish baseline data for lymphoid neoplasm incidence by subtype for six Asian-American ethnic groups.Incident rates were estimated by age and sex for six Asian ethnic groups--Asian Indian/Pakistani, Chinese, Filipino, Japanese, Korean, Vietnamese--in five United States cancer registry areas during 1996-2004. For comparison, rates for non-Hispanic Whites were also estimated.During 1996-2004, Filipinos had the highest (24.0) and Koreans had the lowest incidence (12.7) of total lymphoid neoplasms. By subtype, Vietnamese and Filipinos had the highest incidence for diffuse large B-cell lymphoma (DLBCL) (8.0 and 7.2); Japanese had the highest incidence of follicular lymphoma (2.3). Although a general male predominance of lymphoid neoplasms was observed, this pattern varied by lymphoid neoplasm subtype. Whites generally had higher rates than all Asian ethnic groups for all lymphoid neoplasms and most lymphoma subtypes, although the magnitude of the difference varied by both ethnicity and lymphoma subtype.The observed variations in incidence patterns among Asian ethnic groups in the United States suggest that it may be fruitful to pursue studies that compare Asian populations for postulated environmental and genetic risk factors.
View details for DOI 10.1007/s10552-008-9184-z
View details for Web of Science ID 000260766300017
View details for PubMedID 18543071
View details for PubMedCentralID PMC2581633
-
Polycarboxylates enhance beetle antifreeze protein activity
BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS
2008; 1784 (12): 1942-1948
Abstract
Antifreeze proteins (AFPs) lower the noncolligative freezing point of water in the presence of ice below the ice melting point. The temperature difference between the melting point and the noncolligative freezing point is termed thermal hysteresis (TH). The magnitude of the TH depends on the specific activity and the concentration of AFP, and the concentration of enhancers in the solution. Known enhancers are certain low molecular mass molecules and proteins. Here, we investigated a series of polycarboxylates that enhance the TH activity of an AFP from the beetle Dendroides canadensis (DAFP) using differential scanning calorimetry (DSC). Triethylenetetramine-N,N,N',N'',N''',N'''-hexaacetate, the most efficient enhancer identified in this work, can increase the TH of DAFP by nearly 1.5 fold over than that of the published best enhancer, citrate. The Zn(2+) coordinated carboxylate results in loss of the enhancement ability of the carboxylate on antifreeze activity. There is not an additional increase in TH when a weaker enhancer is added to a stronger enhancer solution. These observations suggest that the more carboxylate groups per enhancer molecule the better the efficiency of the enhancer and that the freedom of motion of these molecules is necessary for them to serve as enhancers for AFP. The hydroxyl groups in the enhancer molecules can also positively affect their TH enhancement efficiency, though not as strongly as carboxylate groups. Mechanisms are discussed.
View details for DOI 10.1016/j.bbapap.2008.06.003
View details for Web of Science ID 000261673300007
View details for PubMedID 18620083
View details for PubMedCentralID PMC2632549
-
Integrated Microstrip Lines With Co-Ta-Zr Magnetic Films
IEEE International Magnetics Conference (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2008: 3103–6
View details for DOI 10.1109/TMAG.2008.2002432
View details for Web of Science ID 000262221200168
-
Giant Magnetoresistive Sensors for DNA Microarray.
IEEE transactions on magnetics
2008; 44 (11): 3989-3991
Abstract
Giant magnetoresistive (GMR) sensors are developed for a DNA microarray. Compared with the conventional fluorescent sensors, GMR sensors are cheaper, more sensitive, can generate fully electronic signals, and can be easily integrated with electronics and microfluidics. The GMR sensor used in this work has a bottom spin valve structure with an MR ratio of 12%. The single-strand target DNA detected has a length of 20 bases. Assays with DNA concentrations down to 10 pM were performed, with a dynamic range of 3 logs. A double modulation technique was used in signal detection to reduce the 1/f noise in the sensor while circumventing electromagnetic interference. The logarithmic relationship between the magnetic signal and the target DNA concentration can be described by the Temkin isotherm. Furthermore, GMR sensors integrated with microfluidics has great potential of improving the sensitivity to 1 pM or below, and the total assay time can be reduced to less than 1 hour.
View details for DOI 10.1109/TMAG.2008.2002795
View details for PubMedID 20824116
View details for PubMedCentralID PMC2933090
-
Giant Magnetoresistive Sensors for DNA Microarray
IEEE International Magnetics Conference (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2008: 3989–91
Abstract
Giant magnetoresistive (GMR) sensors are developed for a DNA microarray. Compared with the conventional fluorescent sensors, GMR sensors are cheaper, more sensitive, can generate fully electronic signals, and can be easily integrated with electronics and microfluidics. The GMR sensor used in this work has a bottom spin valve structure with an MR ratio of 12%. The single-strand target DNA detected has a length of 20 bases. Assays with DNA concentrations down to 10 pM were performed, with a dynamic range of 3 logs. A double modulation technique was used in signal detection to reduce the 1/f noise in the sensor while circumventing electromagnetic interference. The logarithmic relationship between the magnetic signal and the target DNA concentration can be described by the Temkin isotherm. Furthermore, GMR sensors integrated with microfluidics has great potential of improving the sensitivity to 1 pM or below, and the total assay time can be reduced to less than 1 hour.
View details for DOI 10.1109/TMAG.2008.2002795
View details for Web of Science ID 000262221300159
View details for PubMedCentralID PMC2933090
-
Fabrication and Analysis of High-Performance Integrated Solenoid Inductor With Magnetic Core
IEEE International Magnetics Conference (INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2008: 4089–95
View details for DOI 10.1109/TMAG.2008.2003398
View details for Web of Science ID 000262221300184
-
Determining wave vector and material property from the phase-shift of spin-wave propagation
EPL
2008; 84 (2)
View details for DOI 10.1209/0295-5075/84/27009
View details for Web of Science ID 000263598500034
-
TEM analyses of synthetic anti-ferromagnetic (SAF) nanoparticles fabricated using different release layers
11th Conference on Frontiers of Electron Microscopy in Materials Science
ELSEVIER SCIENCE BV. 2008: 1490–94
Abstract
This paper investigates the structural characteristics of templated synthetic anti-ferromagnetic (SAF) magnetic nanoparticles fabricated on two different release layers. When copper was used as the latter, the layered structure of the SAFs was found to be disrupted with wavy multi-layers due to the formation of copper grains from the release layer. By introducing oxygen into the copper release layer before the deposition of the film, the topography of the oxidized copper grains was effectively controlled. This led to the fabrication of SAF nanoparticles with flat multi-layers.
View details for DOI 10.1016/j.ultramic.2008.03.012
View details for Web of Science ID 000260518200014
View details for PubMedID 18672328
View details for PubMedCentralID PMC2582063
-
Giant magnetoresistive biochip for DNA detection and HPV genotyping
BIOSENSORS & BIOELECTRONICS
2008; 24 (1): 99-103
Abstract
A giant magnetoresistive (GMR) biochip based on spin valve sensor array and magnetic nanoparticle labels was developed for inexpensive, sensitive and reliable DNA detection. The DNA targets detected in this experiment were PCR products amplified from Human Papillomavirus (HPV) plasmids. The concentrations of the target DNA after PCR were around 10 nM in most cases, but concentrations of 10 pM were also detectable, which is demonstrated by experiments with synthetic DNA samples. A mild but highly specific surface chemistry was used for probe oligonucleotide immobilization. Double modulation technique was used for signal detection in order to reduce the 1/f noise in the sensor. Twelve assays were performed with an accuracy of approximately 90%. Magnetic signals were consistent with particle coverage data measured with Scanning Electron Microscopy (SEM). More recent research on microfluidics showed the potential of reducing the assay time below one hour. This is the first demonstration of magnetic DNA detection using plasmid-derived samples. This study provides a direct proof that GMR sensors can be used for biomedical applications.
View details for DOI 10.1016/j.bios.2008.03.030
View details for Web of Science ID 000259425300015
View details for PubMedID 18457945
View details for PubMedCentralID PMC2573902
-
Advances in giant magnetoresistance biosensors with magnetic nanoparticle tags: Review and outlook
IEEE TRANSACTIONS ON MAGNETICS
2008; 44 (7): 1687-1702
View details for DOI 10.1109/TMAG.2008.920962
View details for Web of Science ID 000257238200001
-
Nanoscale control of exchange bias with BiFeO3 thin films
NANO LETTERS
2008; 8 (7): 2050-2055
Abstract
We demonstrate a direct correlation between the domain structure of multiferroic BiFeO3 thin films and exchange bias of Co 0.9Fe 0.1/BiFeO3 heterostructures. Two distinct types of interactions - an enhancement of the coercive field ( exchange enhancement) and an enhancement of the coercive field combined with large shifts of the hysteresis loop ( exchange bias) - have been observed in these heterostructures, which depend directly on the type and crystallography of the nanoscale ( approximately 2 nm) domain walls in the BiFeO3 film. We show that the magnitude of the exchange bias interaction scales with the length of 109 degrees ferroelectric domain walls in the BiFeO 3 thin films which have been probed via piezoresponse force microscopy and X-ray magnetic circular dichroism.
View details for DOI 10.1021/nl801391m
View details for Web of Science ID 000257504500046
View details for PubMedID 18547121
-
Electric-field control of local ferromagnetism using a magnetoelectric multiferroic
NATURE MATERIALS
2008; 7 (6): 478-482
Abstract
Multiferroics are of interest for memory and logic device applications, as the coupling between ferroelectric and magnetic properties enables the dynamic interaction between these order parameters. Here, we report an approach to control and switch local ferromagnetism with an electric field using multiferroics. We use two types of electromagnetic coupling phenomenon that are manifested in heterostructures consisting of a ferromagnet in intimate contact with the multiferroic BiFeO(3). The first is an internal, magnetoelectric coupling between antiferromagnetism and ferroelectricity in the BiFeO(3) film that leads to electric-field control of the antiferromagnetic order. The second is based on exchange interactions at the interface between a ferromagnet (Co(0.9)Fe(0.1)) and the antiferromagnet. We have discovered a one-to-one mapping of the ferroelectric and ferromagnetic domains, mediated by the colinear coupling between the magnetization in the ferromagnet and the projection of the antiferromagnetic order in the multiferroic. Our preliminary experiments reveal the possibility to locally control ferromagnetism with an electric field.
View details for DOI 10.1038/nmat2184
View details for Web of Science ID 000256110200022
View details for PubMedID 18438412
-
High-moment antiferromagnetic nanoparticles with tunable magnetic properties
ADVANCED MATERIALS
2008; 20 (8): 1479-?
View details for DOI 10.1002/adma.200703077
View details for Web of Science ID 000255694200015
-
Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent.
Nanotechnology
2008; 19 (16): 165101
Abstract
The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI) contrast agent. The PVP-IO nanoparticles were synthesized by a thermal decomposition method and characterized by x-ray diffraction (XRD), transmission electron microscopy (TEM), dynamic light scattering (DLS), and a superconducting quantum interface device (SQUID). The core size of the particles is about 8-10 nm and the overall size is around 20-30 nm. The measured r(2) (reciprocal of T(2) relaxation time) and r2∗ (reciprocal of T2∗ relaxation time) are 141.2 and 338.1 (s mM)(-1), respectively. The particles are highly soluble and stable in various buffers and in serum. The macrophage uptake of PVP-IO is comparable to that of Feridex as measured by a Prussian blue iron stain and phantom study. The signal intensity of a rabbit liver was effectively reduced after intravenous administration of PVP-IO. Therefore PVP-IO nanoparticles are potentially useful for T(2)-weighted MR imaging.
View details for DOI 10.1088/0957-4484/19/16/165101
View details for PubMedID 21394237
View details for PubMedCentralID PMC3050625
-
Effects of geometries on permeability spectra of CoTaZr magnetic cores for high frequency applications
52nd Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2008
View details for DOI 10.1063/1.2832663
View details for Web of Science ID 000255043200644
-
Inductively coupled circuits with spin wave bus for information processing
JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS
2008; 3 (1): 24-34
View details for DOI 10.1166/jno.2008.003
View details for Web of Science ID 000255548200005
-
Preparation, structural and magnetic characterization of synthetic anti-ferromagnetic (SAF) nanoparticles
PHILOSOPHICAL MAGAZINE
2008; 88 (36): 4225-4241
View details for DOI 10.1080/14786430802585133
View details for Web of Science ID 000261804200002
-
Giant magneto resistive biochips for biomarker detection and genotyping: An overview
AMER INST PHYSICS. 2008: 101–10
View details for Web of Science ID 000257624000010
-
Design and fabrication of integrated solenoid inductors with magnetic cores
IEEE. 2008: 701-+
View details for Web of Science ID 000257141200109
-
Giant Magnetoresistive Biosensors for Molecular Diagnosis: Surface Chemistry and Assay Development
Conference on Biosensing
SPIE-INT SOC OPTICAL ENGINEERING. 2008
View details for DOI 10.1117/12.794434
View details for Web of Science ID 000263133300008
-
The Bacillus subtilis RNA helicase YxiN is distended in solution
BIOPHYSICAL JOURNAL
2008; 94 (1): L1-L3
Abstract
The Bacillus subtilis YxiN protein is a modular three-domain RNA helicase of the DEx(D/H)-box protein family. The first two domains form the highly conserved helicase core, and the third domain confers RNA target binding specificity. Small angle x-ray scattering on YxiN and two-domain fragments thereof shows that the protein has a distended structure in solution, in contrast to helicases involved in replication processes. These data are consistent with a chaperone activity in which the carboxy-terminal domain of YxiN tethers the protein to the vicinity of its targets and the helicase core is free to transiently interact with RNA duplexes, possibly to melt out misfolded elements of secondary structure.
View details for DOI 10.1529/biophysj.107.120709
View details for Web of Science ID 000251615800001
View details for PubMedCentralID PMC2134858
-
Strength of coronal mass ejection-driven shocks near the sun and their importance in predicting solar energetic particle events
ASTROPHYSICAL JOURNAL
2007; 670 (1): 849-856
View details for Web of Science ID 000250965400066
-
Genetic variation and population structure in Native Americans
PLOS GENETICS
2007; 3 (11): 2049-2067
Abstract
We examined genetic diversity and population structure in the American landmass using 678 autosomal microsatellite markers genotyped in 422 individuals representing 24 Native American populations sampled from North, Central, and South America. These data were analyzed jointly with similar data available in 54 other indigenous populations worldwide, including an additional five Native American groups. The Native American populations have lower genetic diversity and greater differentiation than populations from other continental regions. We observe gradients both of decreasing genetic diversity as a function of geographic distance from the Bering Strait and of decreasing genetic similarity to Siberians--signals of the southward dispersal of human populations from the northwestern tip of the Americas. We also observe evidence of: (1) a higher level of diversity and lower level of population structure in western South America compared to eastern South America, (2) a relative lack of differentiation between Mesoamerican and Andean populations, (3) a scenario in which coastal routes were easier for migrating peoples to traverse in comparison with inland routes, and (4) a partial agreement on a local scale between genetic similarity and the linguistic classification of populations. These findings offer new insights into the process of population dispersal and differentiation during the peopling of the Americas.
View details for DOI 10.1371/journal.pgen.0030185
View details for Web of Science ID 000251310200002
View details for PubMedID 18039031
-
Interleukin-8 modulates growth and invasiveness of estrogen receptor-negative breast cancer cells
INTERNATIONAL JOURNAL OF CANCER
2007; 121 (9): 1949-1957
Abstract
Breast cancer, especially estrogen receptor (ER)-negative breast cancer, remains hard to treat despite major advances in surgery and adjuvant therapies. The deletion of ER has been consistently associated with tumor progression, recurrence, metastasis and poor prognosis. Among other differences in biological features, ER-negative breast cancers express high levels of interleukin-8 (IL-8), whereas their ER-positive counterparts do not. IL-8 is a multi-functional cytokine with many important biological functions in tumor formation and development. We aimed to study the role(s) of IL-8 in ER-negative breast cancer progression by using RNA interference to specifically knockdown IL-8 expression in ER-negative breast cancer cell lines MDA-MB-231 and MDA-MB-468. In vitro, suppression of IL-8 led to significant reductions in cell invasion (p<0.001), but had no effects on cell proliferation or cell cycle. In vivo, suppression of IL-8 significantly reduced the microvessel density (p<0.05), and markedly reduced neutrophil infiltration into the tumors (p<0.05). In contrast to in vitro observations, suppression of IL-8 promoted tumor growth in nude mice (p<0.05). Our results imply that the complex roles of IL-8 in the regulation of ER-negative breast cancer progression may in part be related to its potent chemotactic effects on neutrophils, which in turn mediates many of the biological functions of IL-8.
View details for DOI 10.1002/ijc.22930
View details for Web of Science ID 000249718100009
View details for PubMedID 17621625
-
Room temperature exchange bias and spin valves based on BiFeO3/SrRuO3/SrTiO3/Si (001) heterostructures
APPLIED PHYSICS LETTERS
2007; 91 (17)
View details for DOI 10.1063/1.2801695
View details for Web of Science ID 000250468200064
-
CpG island methylation in a mouse model of lymphoma is driven by the genetic configuration of tumor cells
PLOS GENETICS
2007; 3 (9): 1757-1769
Abstract
Hypermethylation of CpG islands is a common epigenetic alteration associated with cancer. Global patterns of hypermethylation are tumor-type specific and nonrandom. The biological significance and the underlying mechanisms of tumor-specific aberrant promoter methylation remain unclear, but some evidence suggests that this specificity involves differential sequence susceptibilities, the targeting of DNA methylation activity to specific promoter sequences, or the selection of rare DNA methylation events during disease progression. Using restriction landmark genomic scanning on samples derived from tissue culture and in vivo models of T cell lymphomas, we found that MYC overexpression gave rise to a specific signature of CpG island hypermethylation. This signature reflected gene transcription profiles and was detected only in advanced stages of disease. The further inactivation of the Pten, p53, and E2f2 tumor suppressors in MYC-induced lymphomas resulted in distinct and diagnostic CpG island methylation signatures. Our data suggest that tumor-specific DNA methylation in lymphomas arises as a result of the selection of rare DNA methylation events during the course of tumor development. This selection appears to be driven by the genetic configuration of tumor cells, providing experimental evidence for a causal role of DNA hypermethylation in tumor progression and an explanation for the tremendous epigenetic heterogeneity observed in the evolution of human cancers. The ability to predict genome-wide epigenetic silencing based on relatively few genetic alterations will allow for a more complete classification of tumors and understanding of tumor cell biology.
View details for DOI 10.1371/journal.pgen.0030167
View details for Web of Science ID 000249767800018
View details for PubMedID 17907813
View details for PubMedCentralID PMC1994712
-
Patterning of high density magnetic nanodot arrays by nanoimprint lithography
53rd International Symposium of the American-Vacuum-Society
A V S AMER INST PHYSICS. 2007: 1294–97
View details for DOI 10.1116/1.2484497
View details for Web of Science ID 000248491700112
-
Tensor nature of permeability and its effects in inductive magnetic devices
10th Joint Magnetism and Magnetic Materials Conference/International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2007: 2373–75
View details for DOI 10.1109/TMAG.2007.892585
View details for Web of Science ID 000246706200096
-
Analytical formula for the tunneling current versus voltage for multilayer barrier structures
AMER INST PHYSICS. 2007
View details for DOI 10.1063/1.2714784
View details for Web of Science ID 000246072200092
-
Branch migration displacement assay with automated heuristic analysis for discrete DNA length measurement using DNA microarrays
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA
2007; 104 (15): 6146-6151
Abstract
The analysis of short tandem repeats (STRs) plays an important role in forensic science, human identification, genetic mapping, and disease diagnostics. Traditional STR analysis utilizes gel- or column-based approaches to analyze DNA repeats. Individual STR alleles are separated and distinguished according to fragment length; thus the assay is generally hampered by its low multiplex capacity. However, use of DNA microarray would employ a simple hybridization and detection for field forensics and biology. Here we demonstrate a rapid, highly sensitive method for STR analysis that utilizes DNA microarray technology. We describe two adaptations to accomplish this: the use of competitive hybridization to remove unpaired ssDNA from an array and the use of neural network classification to automate the analysis. The competitive displacement technique mimics the branch migration process that occurs during DNA recombination. Our technique will facilitate the rapid deduction of identity, length, and number of repeats for the multiple STRs in an unknown DNA sample.
View details for DOI 10.1073/pnas.0700921104
View details for Web of Science ID 000245737500012
View details for PubMedID 17389407
View details for PubMedCentralID PMC1838402
-
Spin filter based tunnel junctions
JOURNAL OF APPLIED PHYSICS
2006; 100 (12)
View details for DOI 10.1063/1.2382720
View details for Web of Science ID 000243157900058
-
A novel zero-drift detection method for highly sensitive GMR biochips
41st IEEE International Magnetics Conference (Intermag 2006)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2006: 3560–62
View details for DOI 10.1109/TMAG.2006.879615
View details for Web of Science ID 000240888700430
-
A methodology for finite element modeling of magnetic inductive devices with in-plane multidomain pattern
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2006: 3222–24
View details for DOI 10.1109/TMAG.2006.880106
View details for Web of Science ID 000240888700318
-
Permeability of fine magnetic particles: Measurements, calibration, and pitfalls
41st IEEE International Magnetics Conference (Intermag 2006)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2006: 3335–37
View details for DOI 10.1109/TMAG.2006.878872
View details for Web of Science ID 000240888700356
-
Room-temperature spin filtering in a CoFe2O4/MgAl2O4/Fe3O4 magnetic tunnel barrier
PHYSICAL REVIEW B
2006; 74 (1)
View details for DOI 10.1103/PhysRevB.74.014418
View details for Web of Science ID 000239426400070
-
Spin valve sensors for ultrasensitive detection of superparamagnetic nanoparticles for biological applications.
Sensors and actuators. A, Physical
2006; 126 (1): 98-106
Abstract
We present giant magnetoresistance (GMR) spin valve sensors designed for detection of superparamagnetic nanoparticles as potential biomolecular labels in magnetic biodetection technology. We discuss the sensor design and experimentally demonstrate that as few as approximately 23 monodisperse 16-nm superparamagnetic Fe(3)O(4) nanoparticles can be detected by submicron spin valve sensors at room temperature without resorting to lock-in detection. A patterned self-assembly method of nanoparticles, based on a polymer-mediated process and fine lithography, is developed for the detection. It is found that sensor signal increases linearly with the number of nanoparticles.
View details for DOI 10.1016/j.sna.2005.10.001
View details for PubMedID 18414592
View details for PubMedCentralID PMC2293286
-
Spin valve biosensors: Signal dependence on nanoparticle position
JOURNAL OF APPLIED PHYSICS
2006; 99 (8)
View details for DOI 10.1063/1.2170052
View details for Web of Science ID 000237404200633
-
Peptide-labeled near-infrared quantum dots for imaging tumor vasculature in living subjects
NANO LETTERS
2006; 6 (4): 669-676
Abstract
We report the in vivo targeting and imaging of tumor vasculature using arginine-glycine-aspartic acid (RGD) peptide-labeled quantum dots (QDs). Athymic nude mice bearing subcutaneous U87MG human glioblastoma tumors were administered QD705-RGD intravenously. The tumor fluorescence intensity reached maximum at 6 h postinjection with good contrast. The results reported here open up new perspectives for integrin-targeted near-infrared optical imaging and may aid in cancer detection and management including imaging-guided surgery.
View details for DOI 10.1021/nl052405t
View details for Web of Science ID 000236916200015
View details for PubMedID 16608262
-
Spin valve sensors for ultrasensitive detection of superparamagnetic nanoparticles for biological applications
SENSORS AND ACTUATORS A-PHYSICAL
2006; 126 (1): 98-106
Abstract
We present giant magnetoresistance (GMR) spin valve sensors designed for detection of superparamagnetic nanoparticles as potential biomolecular labels in magnetic biodetection technology. We discuss the sensor design and experimentally demonstrate that as few as approximately 23 monodisperse 16-nm superparamagnetic Fe(3)O(4) nanoparticles can be detected by submicron spin valve sensors at room temperature without resorting to lock-in detection. A patterned self-assembly method of nanoparticles, based on a polymer-mediated process and fine lithography, is developed for the detection. It is found that sensor signal increases linearly with the number of nanoparticles.
View details for DOI 10.1016/j.sna.2005.10.001
View details for Web of Science ID 000235103900015
View details for PubMedCentralID PMC2293286
-
CMOS integrated DNA Microarray based on GMR sensors
IEEE International Electron Devices Meeting
IEEE. 2006: 451–454
View details for Web of Science ID 000247357700112
-
A novel method for STR-based DNA profiling using microarrays
JOURNAL OF FORENSIC SCIENCES
2005; 50 (5): 1109-1113
Abstract
We describe a novel method for rapidly identifying and distinguishing between different DNA sequences using short tandem repeat (STR) analysis and DNA microarrays. The method can be used to deduce identity, length, and number of STRs of the target molecule. We refer to this technique as the "variable-length probe array" method for STR profiling (VLPA). The method involves hybridization of the unknown STR target sequence to a DNA microarray displaying complementary probes that vary in length to cover the range of possible STRs. A post-hybridization enzymatic digestion of the DNA hybrids is then used to selectively remove labeled single-stranded regions of DNA from the microarray surface. The number of repeats in the unknown target is then deduced based on the pattern of target DNA that remains hybridized to the array. This DNA profiling technique is useful for performing forensic analysis to uniquely identify individual humans or other species.
View details for Web of Science ID 000231660300013
View details for PubMedID 16225215
-
Bio-functionalization of monodisperse magnetic nanoparticles and their use as biomolecular labels in a magnetic tunnel junction based sensor
JOURNAL OF PHYSICAL CHEMISTRY B
2005; 109 (26): 13030-13035
Abstract
Monodisperse magnetic nanoparticles (NPs) could enable the ultra-sensitive magnetic detection of biological analytes. However, rendering these particles biocompatible has remained a challenge. We report the bio-functionalization and detection of 12-nm manganese ferrite NPs. We have achieved the site-specific binding of biotin-functionalized NPs onto avidin-patterned silicon oxide substrates and DNA-functionalized NPs onto complementary DNA-patterned silicon oxide substrates. Utilizing scanning SQUID microscopy, we show that these substrate-bound NPs retain their magnetic properties. Finally, we demonstrate a novel method of detecting either protein binding or DNA hybridization at room temperature using the NPs and a magnetic tunnel-junction-based biosensor situated in orthogonal magnetic fields.
View details for DOI 10.1021/jp051098c
View details for Web of Science ID 000230224700053
View details for PubMedID 16852617
-
Observation of the Verwey transition in thin magnetite films
JOURNAL OF APPLIED PHYSICS
2005; 97 (12)
View details for DOI 10.1063/1.1929092
View details for Web of Science ID 000230278100070
-
Room-temperature spin coherence in ZnO
APPLIED PHYSICS LETTERS
2005; 86 (23)
View details for DOI 10.1063/1.1946204
View details for Web of Science ID 000230087400037
-
Composite-an isotropy amorphous magnetic materials for high-frequency devices
49th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2005
View details for DOI 10.1063/1.1858111
View details for Web of Science ID 000230168300312
-
Soft magnetic granular material Co-Fe-Hf-O for micromagnetic device applications
49th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2005
View details for DOI 10.1063/1.1853228
View details for Web of Science ID 000230168300308
-
Towards a magnetic microarray for sensitive diagnostics
5th International Conference on Scientific and Clinical Applications of Magnetic Carriers
ELSEVIER SCIENCE BV. 2005: 731–36
View details for DOI 10.1016/j.jmmm.2005.02.054
View details for Web of Science ID 000229661400108
-
DNA-functionalized MFe2O4 (M = Fe, Co, or Mn) nanoparticles and their hybridization to DNA-functionalized surfaces
LANGMUIR
2005; 21 (7): 3096-3103
Abstract
Magnetic MFe2O4 (M = Fe, Co, or Mn) nanoparticles with uniform diameters in the 4-20 nm range and with excellent material properties, reported previously, can be rendered soluble in water or aqueous buffers using a combination of alkylphosphonate surfactants and other surfactants such as ethoxylated fatty alcohols or phospholipids. Surfactant-modified oligonucleotides can be incorporated into the particles' organic shell. The particles can withstand salt concentrations up to 0.3 M, temperatures up to 90 degrees C, and various operations such as concentration to dryness, column or membrane separations, and electrophoresis. The particles can be selectively hybridized to DNA-functionalized gold surfaces with high coverages using a two-story monolayer structure. These particles may find valuable applications involving the magnetic detection of small numbers of biomolecules using spin valves, magnetic tunnel junctions, or other sensors.
View details for Web of Science ID 000228042400068
View details for PubMedID 15779990
View details for PubMedCentralID PMC2924586
-
Growth and characterization of copper nanoclusters embedded in SiC matrix
THIN SOLID FILMS
2005; 473 (2): 267-271
View details for DOI 10.1016/j.tsf.2004.07.079
View details for Web of Science ID 000226169800016
-
Dumbbell-like bifunctional Au-Fe3O4 nanoparticles
NANO LETTERS
2005; 5 (2): 379–82
View details for DOI 10.1021/nl047955q
View details for Web of Science ID 000227100500034
-
Shape-controlled synthesis and shape-induced texture of MnFe2O4 nanoparticles
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY
2004; 126 (37): 11458-11459
Abstract
Monodisperse MnFe2O4 nanoparticles with cubelike and polyhedron shapes were synthesized by reaction of Fe(acac)3 and Mn(acac)2 with 1,2-hexadecanediol, oleic acid, and oleylamine. Controlled evaporation of the particle dispersion led to nanoparticle superlattices. The crystal orientation of the particle in the assembly depends on the shape of the particles, with particles in a cubelike shape showing (100) texture and those in the polyhedron shape exhibiting (110) texture.
View details for DOI 10.1021/ja045911d
View details for Web of Science ID 000223921800029
View details for PubMedID 15366890
-
Calculation of shape anisotropy for micropatterned thin Fe-Ni films for on-chip RF applications
9th Joint Magnetism and Magnetic Materials Conference/ International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2004: 2835–37
View details for DOI 10.1109/TMAG.2004.835096
View details for Web of Science ID 000223446700276
-
Model and experiment of detecting multiple magnetic nanoparticles as biomolecular labels by spin valve sensors
9th Joint Magnetism and Magnetic Materials Conference/ International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2004: 3000–3002
View details for DOI 10.1109/TMAG.2004.830626
View details for Web of Science ID 000223446700330
-
Effect of patterned magnetic shields on high-frequency integrated inductors
9th Joint Magnetism and Magnetic Materials Conference/ International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2004: 2017–19
View details for DOI 10.1109/TMAG.2004.832161
View details for Web of Science ID 000223446700009
-
Biochemical stability of components for use in a DNA detection system
9th Joint Magnetism and Magnetic Materials Conference/ International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2004: 3012–14
View details for DOI 10.1109/TMAG.2004.830229
View details for Web of Science ID 000223446700334
-
Inelastic electron tunnelling spectroscopy of magnetic tunnel junctions with AlN and AlON barriers
International Conference on Magnetism (ICM 2003)
ELSEVIER SCIENCE BV. 2004: 1952–1953
View details for DOI 10.1016/j.jmmm.2003.12.1195
View details for Web of Science ID 000222236800135
-
Monodisperse MFe2O4 (M = Fe, Co, Mn) nanoparticles
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY
2004; 126 (1): 273-279
Abstract
High-temperature solution phase reaction of iron(III) acetylacetonate, Fe(acac)(3), with 1,2-hexadecanediol in the presence of oleic acid and oleylamine leads to monodisperse magnetite (Fe(3)O(4)) nanoparticles. Similarly, reaction of Fe(acac)(3) and Co(acac)(2) or Mn(acac)(2) with the same diol results in monodisperse CoFe(2)O(4) or MnFe(2)O(4) nanoparticles. Particle diameter can be tuned from 3 to 20 nm by varying reaction conditions or by seed-mediated growth. The as-synthesized iron oxide nanoparticles have a cubic spinel structure as characterized by HRTEM, SAED, and XRD. Further, Fe(3)O(4) can be oxidized to Fe(2)O(3), as evidenced by XRD, NEXAFS spectroscopy, and SQUID magnetometry. The hydrophobic nanoparticles can be transformed into hydrophilic ones by adding bipolar surfactants, and aqueous nanoparticle dispersion is readily made. These iron oxide nanoparticles and their dispersions in various media have great potential in magnetic nanodevice and biomagnetic applications.
View details for DOI 10.1021/ja0380852
View details for Web of Science ID 000187945400063
View details for PubMedID 14709092
-
Damping criteria of magnetization in ferromagnetic ellipsoids
14th Annual Magnetic Recording Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2004: 253–56
View details for DOI 10.1109/TMAG.2003.821185
View details for Web of Science ID 000188806600015
-
Analytical and micromagnetic modeling for detection of a single magnetic microbead or nanobead by spin valve sensors
International Magnetics Conference
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2003: 3313–15
View details for DOI 10.1109/TMAG.2003.816760
View details for Web of Science ID 000185722100352
-
Detection of single micron-sized magnetic bead and magnetic nanoparticles using spin valve sensors for biological applications
47th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2003: 7557–59
View details for DOI 10.1063/1.1540176
View details for Web of Science ID 000182822300373
-
Fe3O4 and its magnetic tunneling junctions grown by ion beam deposition
JOURNAL OF APPLIED PHYSICS
2003; 93 (10): 7954–56
View details for DOI 10.1063/1.1558633
View details for Web of Science ID 000182822600105
-
Anisotropy dispersion effects on the high frequency behavior of soft magnetic Fe-Co-N thin films
47th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2003: 6468–70
View details for DOI 10.1063/1.1557347
View details for Web of Science ID 000182822300015
-
Transport in magnetically doped magnetic tunnel junctions
International Magnetics Conference (Intermag Europe 2002)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2002: 2721–23
View details for DOI 10.1109/TMAG.2002.803136
View details for Web of Science ID 000178867200274
-
High-frequency microinductors with amorphous magnetic ground planes
International Magnetics Conference (Intermag Europe 2002)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2002: 3168–70
View details for DOI 10.1109/TMAG.2002.802403
View details for Web of Science ID 000178867200414
-
Measurement and analysis of noise sources in giant magnetoresistive sensors up to 6 GHz
IEEE TRANSACTIONS ON MAGNETICS
2002; 38 (5): 3545-3555
View details for DOI 10.1109/TMAG.2002.802706
View details for Web of Science ID 000178867300022
-
Soft magnetism of Fe-Co-N thin films with a Permalloy underlayer
JOURNAL OF APPLIED PHYSICS
2002; 92 (3): 1477–82
View details for DOI 10.1063/1.1491017
View details for Web of Science ID 000176907700049
-
Optimization of granular double-layer perpendicular media
1st North American Perpendicular Magnetic Recording Conference (NAPMRC)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2002: 1627–31
View details for Web of Science ID 000176925600005
-
Intermixing effects in ultrathin barrier magnetic tunneling junctions
46th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 2002: 7950–52
View details for DOI 10.1063/1.1452231
View details for Web of Science ID 000175576400042
-
Epitaxial growth and characterization of Fe3O4 on Ru underlayer
AMER INST PHYSICS. 2002: 7146–48
View details for DOI 10.1063/1.1448299
View details for Web of Science ID 000175575100113
-
Junction area dependence of tunneling magnetoresistance
International Symposium on Physics of Magnetic Materials/International Symposium on Advanced Magnetic Technologies
ELSEVIER SCIENCE BV. 2002: 129–31
View details for Web of Science ID 000175187300042
-
Extending the bandwidth of magnetic tunnel junction sensors by a buffer amplifier
IEEE TRANSACTIONS ON MAGNETICS
2002; 38 (1): 295-297
View details for Web of Science ID 000174273600015
-
Designing disk drive interconnects to obtain a desired transmitted write current waveform
12th Annual Magnetic Recording Conference (TMRC)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2002: 55–60
View details for Web of Science ID 000174273500011
-
High-frequency behavior and damping of Fe-Co-N-based high-saturation soft magnetic films
12th Annual Magnetic Recording Conference (TMRC)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2002: 146–50
View details for Web of Science ID 000174273500027
-
Oxidation kinetics of tunnel barrier and its effect on exchange bias of proximity interface
APPLIED PHYSICS LETTERS
2001; 79 (25): 4130-4132
View details for Web of Science ID 000172682300020
-
Microstructures of FeTaN films in the neck region of magnetic recording heads
8th Joint Magnetism and Magnetic Materials International Magnetics Conference (MMM-INTERMAG)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2001: 3039–42
View details for Web of Science ID 000170911100014
-
Epitaxial growth of aluminum on permalloy
THIN SOLID FILMS
2001; 381 (1): 160-163
View details for Web of Science ID 000166467800022
-
Spin-dependent tunneling junctions with AlN and AlON barriers
APPLIED PHYSICS LETTERS
2000; 77 (14): 2219-2221
View details for Web of Science ID 000089524900047
-
Properties of a new soft magnetic material
Nature
2000; 407 (6801): 150-1
View details for DOI 10.1038/35025140
View details for PubMedID 11001044
-
Sandwich films - Properties of a new soft magnetic material
NATURE
2000; 407 (6801): 150–51
View details for DOI 10.1038/35025142
View details for Web of Science ID 000089241000035
-
Electrostatic discharge testing of tunneling magnetoresistive (TMR) devices
International Magnetics Conference (INTERMAG 2000)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 2000: 2809–11
View details for Web of Science ID 000167371700210
-
Electronic scattering from Co/Cu interfaces: In situ measurement, comparison with microstructure, and failure of semiclassical free-electron models
AMER INST PHYSICS. 2000: 5185–87
View details for DOI 10.1063/1.373289
View details for Web of Science ID 000086727200172
-
Magnetic properties, microstructures, and corrosion resistance of high-saturation FeMoN and FeRhN films for recording heads
IEEE TRANSACTIONS ON MAGNETICS
2000; 36 (2): 513–20
View details for DOI 10.1109/20.825827
View details for Web of Science ID 000085790200012
-
Electronic scattering from Co/Cu interfaces: In situ measurement and comparison with theory
PHYSICAL REVIEW B
2000; 61 (2): 1330-1335
View details for Web of Science ID 000085760000074
-
Magnetic properties and high-frequency responses of high moment FeTaN/AlN laminates for high-data-rate magnetic recording
IEEE TRANSACTIONS ON MAGNETICS
1999; 35 (5): 2502-2504
View details for Web of Science ID 000083151100092
-
In-situ characterization of oxide growth for fabricating spin-dependent tunnel junctions
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1999: 2949–51
View details for DOI 10.1109/20.801043
View details for Web of Science ID 000083151100232
-
Study of DC plasma oxidized Al2O3 barriers in spin dependent tunneling junctions using high resolution transmission electron microscopy
1999 International Magnetics Conference (INTERMAG 99)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1999: 2922–24
View details for Web of Science ID 000083151100223
-
Trellis codes for transition jitter noise
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1999: 2328–30
View details for DOI 10.1109/20.800815
View details for Web of Science ID 000083151100036
-
In-situ conductance measurement of surface specularity of NiFe, Co, Cu, Ag and Ta thin films
1999 International Magnetics Conference (INTERMAG 99)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1999: 2979–81
View details for Web of Science ID 000083151100242
-
Determination of barrier oxidation states in spin dependent tunneling structures
JOURNAL OF APPLIED PHYSICS
1999; 85 (11): 7803-7806
View details for Web of Science ID 000080354300043
-
Direct measurement of surface scattering in giant magnetoresistance spin valves
JOURNAL OF APPLIED PHYSICS
1999; 85 (10): 7345–48
View details for DOI 10.1063/1.369360
View details for Web of Science ID 000080136000050
-
Spin-dependent tunneling junctions with Fe55Ni45 electrodes and in situ resistive measurement of oxide growth
APPLIED PHYSICS LETTERS
1999; 74 (17): 2528-2530
View details for Web of Science ID 000079855900042
-
Investigation of ion beam deposited spin valve interface structure by Co-59 nuclear magnetic resonance
AMER INST PHYSICS. 1999: 4439–41
View details for Web of Science ID 000079850700053
-
Magnetic and microstructural characterization of FeTaN high saturation materials for recording heads
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1999: 782–87
View details for DOI 10.1109/20.750645
View details for Web of Science ID 000079022000031
-
Inversion of spin polarization and tunneling magnetoresistance in spin-dependent tunneling junctions
PHYSICAL REVIEW LETTERS
1999; 82 (3): 616-619
View details for Web of Science ID 000078059200039
-
Epitaxial growth of atomically flat spin dependent tunneling junctions
Symposium on Epitaxial Growth-Principles and Applications
MATERIALS RESEARCH SOCIETY. 1999: 73–78
View details for Web of Science ID 000082591100010
-
Study of natural oxidation of ultra-thin aluminum layers with in-situ resistance measurement
Symposium U on In Situ Process Diagnostics and Modelling, at the 1999 MRS Spring Meeting
MATERIALS RESEARCH SOCIETY. 1999: 185–190
View details for Web of Science ID 000082591000026
-
Novel sol-gel processing for polycrystalline and epitaxial thin films of La0.67Ca0.33MnO3 with colossal magnetoresistance
JOURNAL OF MATERIALS RESEARCH
1998; 13 (11): 3234-3240
View details for Web of Science ID 000076758200029
-
Effect of microstructure on resistivity and GMR ratio in ion beam deposited spin valves
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1998: 957–59
View details for DOI 10.1109/20.706325
View details for Web of Science ID 000074852300044
-
Texture and magnetic properties of FeTaN films bias-sputtered on sloping surfaces
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1998: 1444–46
View details for DOI 10.1109/20.706577
View details for Web of Science ID 000074852300203
-
Spin-dependent tunneling junctions with hard magnetic layer pinning
7th Joint Magnetism and Magnetic Materials / International Magnetics Conference
AMER INST PHYSICS. 1998: 6685–87
View details for Web of Science ID 000077795500154
-
Microstructures and properties of high saturation soft magnetic materials for advanced recording reads
Symposium L on Materials for High-Density Magnetic Recording / Symposium M on Integrated Magneto-Optics at the MRS Spring Meeting
MATERIALS RESEARCH SOCIETY. 1998: 5–5
View details for Web of Science ID 000076893400001
-
Read-back nonlinearity in longitudinal keepered recording
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1998: 51–56
View details for DOI 10.1109/20.663440
View details for Web of Science ID 000071713400010
-
Intra- and inter-pattern non-linearities in high density magnetic recording
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1998: 45–50
View details for DOI 10.1109/20.663438
View details for Web of Science ID 000071713400009
-
Colossal magnetoresistance in sol-gel derived epitaxial thin film of co-doped La1-xCaxMnOx
JOURNAL OF ELECTRONIC MATERIALS
1998; 27 (1): 1-7
View details for Web of Science ID 000071470700001
-
Domain structures and magnetic properties of FeN films sputter-deposited on sloping surfaces
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 2833–35
View details for DOI 10.1109/20.617747
View details for Web of Science ID A1997XW56400071
-
In situ and ex situ observation of spin valves obtained by ion-beam deposition
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 3595–97
View details for DOI 10.1109/20.619508
View details for Web of Science ID A1997XW56500031
-
Corrosion resistance of low coercivity, high moment FeXN (X=Rh, Mo) thin film head materials
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 2848–50
View details for DOI 10.1109/20.617752
View details for Web of Science ID A1997XW56400076
-
The dependence of overwrite on non-linear transition shift
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 2689–91
View details for DOI 10.1109/20.617446
View details for Web of Science ID A1997XW56400023
-
Linearizing the read process for write nonlinearity measurements
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 2692–94
View details for DOI 10.1109/20.617447
View details for Web of Science ID A1997XW56400024
-
Ion beam deposition and structural characterization of GMR spin valves
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 2369–74
View details for DOI 10.1109/20.573860
View details for Web of Science ID A1997WX30600021
-
Soft a-CoZr-based spin valves
AMER INST PHYSICS. 1997: 4007–
View details for Web of Science ID A1997WV53600102
-
Generalized method for measuring read-back nonlinearity using a spin stand
AMER INST PHYSICS. 1997: 4828–30
View details for DOI 10.1063/1.365474
View details for Web of Science ID A1997WV53700027
-
Effects of lamination on soft magnetic properties of FeN films on sloping surfaces
41st Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 1997: 4507–9
View details for Web of Science ID A1997WV53600292
-
Non-linear interactions in a series of transitions
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1997: 956–61
View details for DOI 10.1109/20.560138
View details for Web of Science ID A1997WF01300043
-
Effect of ion bombardment on the long-range chemical order in FePd films
JOURNAL OF APPLIED PHYSICS
1996; 80 (10): 5753–58
View details for DOI 10.1063/1.363629
View details for Web of Science ID A1996VU98700031
-
FeN/AlN multilayer films for high moment thin film recording heads
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1996: 3509–11
View details for DOI 10.1109/20.538673
View details for Web of Science ID A1996VM25800049
-
Granular magnetic cobalt metal/polymer thin film system
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1996: 4475–77
View details for DOI 10.1109/20.538902
View details for Web of Science ID A1996VM25900062
-
Stress and magnetic properties in high moment FeN thin films
AMER INST PHYSICS. 1996: 5901–3
View details for DOI 10.1063/1.362166
View details for Web of Science ID A1996UG87800115
-
Structural comparisons of ion beam and de magnetron sputtered spin valves by high-resolution transmission electron microscopy
40th Annual Conference on Magnetism and Magnetic Materials
AMER INST PHYSICS. 1996: 6393–95
View details for Web of Science ID A1996UG87800298
-
MAGNETIC-PROPERTIES OF NIFE SPUTTERED ON SLOPING SURFACES
1995 IEEE International Magnetics Conference (INTERMAG 95)
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1995: 3817–19
View details for Web of Science ID A1995TD55800122
-
MODELING OF SUBMICRON TRACKWIDTH INDUCTIVE WRITE HEAD DESIGNS
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1995: 2687–89
View details for DOI 10.1109/20.490093
View details for Web of Science ID A1995TD55600035
-
A PERPENDICULAR CONTACT RECORDING HEAD WITH HIGH MOMENT LAMINATED FEALN/NIFE POLE TIPS
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1994: 3897–99
View details for DOI 10.1109/20.333937
View details for Web of Science ID A1994PU42900034
-
FEALN/SIO2 AND FEALN/AL2O3 MULTILAYERS FOR THIN-FILM RECORDING-HEADS (INVITED)
AMER INST PHYSICS. 1993: 6212–17
View details for DOI 10.1063/1.352702
View details for Web of Science ID A1993LD86500026
-
MICROSTRUCTURAL INVESTIGATIONS OF FEN AND FEALN THIN-FILMS FOR RECORDING HEAD APPLICATIONS
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1992: 2418–20
View details for DOI 10.1109/20.179511
View details for Web of Science ID A1992JN87700105
-
IMPROVED HIGH MOMENT FEALN/SIO2 LAMINATED MATERIALS FOR THIN-FILM RECORDING-HEADS
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC. 1991: 4879–81
View details for DOI 10.1109/20.278977
View details for Web of Science ID A1991HB66100078
-
NITROGEN-DOPED IRON-FILM-BASED LAMINATED MATERIALS FOR THIN-FILM RECORDING-HEADS
AMER INST PHYSICS. 1991: 5625–27
View details for DOI 10.1063/1.347943
View details for Web of Science ID A1991FL73500108
-
HIGH MOMENT SOFT AMORPHOUS COFEZRRE THIN-FILM MATERIALS
AMER INST PHYSICS. 1990: 5114–16
View details for DOI 10.1063/1.346065
View details for Web of Science ID A1990DD73900258
-
RF-DIODE-SPUTTERED IRON NITRIDE FILMS FOR THIN-FILM RECORDING HEAD MATERIALS
AMER INST PHYSICS. 1990: 5134–36
View details for DOI 10.1063/1.344665
View details for Web of Science ID A1990DD73900264
-
SYNTHESIS, STRUCTURE, AND PROPERTIES OF SR2CUO2CL2
PHYSICAL REVIEW B
1990; 41 (4): 1921–25
View details for DOI 10.1103/PhysRevB.41.1921
View details for Web of Science ID A1990CM84700024